AssayIndex

AX-2026-043027

Ipamorelin · 5 mg declared · Zhuhai Kerui Biotechnology Co., Ltd. · lot KP-2512-X4745

MARGINALPURITY ONLY
Report ID
AX-2026-043027
Compound
Ipamorelin
Compound class
Growth-hormone axis peptides
Supplier
KP — Zhuhai Kerui Biotechnology Co., Ltd.
Batch / lot
KP-2512-X4745
Declared label claim
5mg
Laboratory
Janoshik Analytical
Assay date
19 Mar 2026
Submitted
12 Apr 2026
Quarter
2026-Q1
Submitter
label_claim
Sample provenance
Supplier-supplied
Section 1

Results

Measured against the index acceptance specification for the growth-hormone axis peptides class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 30 min gradient, 214 nm99.01% area≥ 99.0PASS
Total impuritiesRP-HPLC, sum of reported peaks0.99% area≤ 1.0PASS
Largest single impurityRP-HPLC — des-Lys (−128 Da)0.68% area≤ 1.00PASS
Identitynot ordered on this submissionnot determinedrequired for VERIFIED statusNOT TESTED
Total peptide contentby difference from the gravimetric mass balance87.86%w/wNOT TESTED
Target-compound contenttotal peptide content × purity86.99%w/wNOT TESTED
Gross fill (as weighed)five-place balance, under nitrogen5.15mg5 mg declaredNOT TESTED
Recovered target peptidegross fill × target content4.480mg5 mg claimNOT TESTED
Recovery against label claimrecovered ÷ claim89.6%90.0 – 110.0FAIL
Water contentKarl Fischer, coulometric, duplicate2.91%≤ 9.0PASS
Counter-ion (acetate)anion-exchange ion chromatography8.45%≤ 12.0PASS
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.78%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitymembrane filtration, USP <71>, 14 dNo growth at 14 dno growthPASS
Appearancevisual, diffuse light, black and white backgroundWhite lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration4.672.5 – 8.0PASS
Retention time (observed)RP-HPLC, 30 min gradient8.17min8.24 ± 0.25 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.220.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²95,323≥ 20,000PASS
Resolution to nearest impurityvs [D-Trp]-epimer1.11no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

0390278041170615608 Ipamorelin8.17 min · 99.01 % 7.95 same trace · ×100 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 05101520253035 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 30 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 95,323, and skew follows the reported asymmetry factor of 1.22. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.68 % impurity against a 99.01 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1Ipamorelin — main peak8.174,812,19399.01
2des-Lys (−128 Da)7.9533,0500.68-128.095
3C-terminal free acid (+1 Da)8.359,2350.19+0.984
4oxidised Trp (+16 Da)7.833,8880.08+15.995
5[D-Trp]-epimer8.051,4580.030.000
6Aib-deletion sequence (−85 Da)7.894860.01-85.053
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

ComponentDetermination%w/w of cake
WaterKarl Fischer2.91
Counter-ion (acetate)ion chromatography8.45
Residual solvent + inorganic residueestimated0.78
Total peptide contentby difference87.86
Total100.00 CLOSES

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)98.6399.01divergence -0.05 pp vs batch median
Total impurities (% area)1.370.99
Largest single impurity (% area)0.830.68
Water (%)0.72.91
Counter-ion (%)not stated8.45
Peptide content (%w/w)not stated87.86
Endotoxin (EU/mg)not statednot determined
Method stated on certificateNOno method section — the result cannot be reconciled against any other
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Supplier-supplied
Evidentiary weight
Weaker evidence. Read with the caveat below.
Chain of custody
Supplier despatch → laboratory direct (courier, cold pack, 6 d) → assay. Submitter did not handle the vial.
Assay date
19 Mar 2026
Submitted to the index
12 Apr 2026
Laboratory
Janoshik Analytical, Ostrava, Czechia
Method basis
30 min gradient · high-resolution MS
Verification status
PURITY ONLY
Section 6

Annotations 2

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

sample_vs_retail
The comparison worth funding is a paired one on the same lot code, same week, one vial from each channel. Two tests, and the answer is unambiguous for that lot.
underfill_3to1
Gravimetric fill checks in this index show under-fill outnumbering over-fill by roughly three to one. That asymmetry is a fill-target convention rather than a random process, and it is entirely legible once content is measured.
Section 7

Related records

Same batch — lot KP-2512-X4745 n=3

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043025KP-2512-X4745PeptideMeter2026-Q198.612.46Buyer-sourced0FAIL
AX-2026-043026KP-2512-X4745Janoshik2026-Q198.682.85Laboratory-retained0FAIL
Other recent Ipamorelin records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041377QYBQYB-2605-H3558Nordanalyt2026-Q399.934.35Buyer-sourced0PASS
AX-2026-041913SinoPepSNP-2606-L4478PeptideMeter2026-Q398.885.28Buyer-sourced0FAIL
AX-2026-041914SinoPepSNP-2606-L4478Janoshik2026-Q399.145.49Buyer-sourced0PASS
AX-2026-041909SinoPepSNP-2606-L4478PeptideMeter2026-Q399.005.4889.5Buyer-sourced1MARGINAL
AX-2026-041895SinoPepSNP-2602-B3833Janoshik2026-Q399.934.72105.9Buyer-sourced1MARGINAL
AX-2026-041898SinoPepSNP-2602-B3833Nordanalyt2026-Q399.934.5496.0Buyer-sourced1MARGINAL
AX-2026-041899SinoPepSNP-2602-B3833PeptideMeter2026-Q399.934.9690.1Buyer-sourced1MARGINAL
AX-2026-041891SinoPepSNP-2602-B3833Janoshik2026-Q399.935.11Buyer-sourced1MARGINAL
Other recent KP records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043095RetatrutideKP-2607-H5774Janoshik2026-Q395.815.48105.2Buyer-sourced0FAIL
AX-2026-043094RetatrutideKP-2607-H5774PeptideMeter2026-Q396.326.40Buyer-sourced0FAIL
AX-2026-043096RetatrutideKP-2607-H5774VendorInvestigate2026-Q396.486.05104.9Buyer-sourced0FAIL
AX-2026-043090RetatrutideKP-2607-H5774Janoshik2026-Q396.465.81Buyer-sourced0FAIL
AX-2026-043091RetatrutideKP-2607-H5774Janoshik2026-Q396.135.94Buyer-sourced0FAIL
AX-2026-043077TB-500KP-2605-C5214Janoshik2026-Q299.615.6490.2Buyer-sourced0PASS
AX-2026-043093RetatrutideKP-2607-H5774Janoshik2026-Q396.545.54Buyer-sourced0PASS
AX-2026-043092RetatrutideKP-2607-H5774Medutest2026-Q396.646.12Buyer-sourced1FAIL