Gravimetric fill checks. Under-fill outnumbers over-fill three to one.

first seen 2025-Q111 records submitted6 annotations
Section 1

Contribution

Both submits records and annotates other people's.

Records submitted 11 n=11
Annotations 6 n=6
Median purity submitted 98.62% n=11
Suppliers covered 8 n=11
Section 2

Records submitted

A submitter chose to buy this material and to pay for this assay. That choice is the selection mechanism behind the whole index and it is not random.

ReportCompoundSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041337SemaglutideWWBWWB-2606-N3192Nordanalyt2026-Q399.523.92Buyer-sourced0PASS
AX-2026-042601SemaglutideHJHJ-2608-C7002Janoshik2026-Q399.193.49Buyer-sourced0PASS
AX-2026-041649SS-31 (Elamipretide)FGPFGP-2601-R8955Janoshik2026-Q298.534.12103.8Buyer-sourced1MARGINAL
AX-2026-042648MK-677 (Ibutamoren mesylate)SWBSWB-2605-B7365Janoshik2026-Q299.932.6096.9Supplier-supplied0FAIL
AX-2026-043401MOTS-cWXTWXT-2512-K3109VendorInvestigate2026-Q197.712.07Buyer-sourced0FAIL
AX-2025-020438SemaxKPKP-2502-H5248VendorInvestigate2025-Q298.295.8488.9Buyer-sourced1FAIL
AX-2025-020008RetatrutideSWBSWB-2411-R7167Janoshik2025-Q198.344.2398.1Buyer-sourced0PASS
AX-2025-020596SermorelinSSASSA-2409-X7161Medutest2025-Q198.464.84100.9Buyer-sourced1FAIL
AX-2025-019045N-Acetyl Semax AmideASYASY-{CAT}-2147Janoshik2025-Q199.938.16102.4Buyer-sourced0PASS
AX-2024-004989BPC-157KPKP-2407-L4785Janoshik2024-Q498.622.37Buyer-sourced0PASS
AX-2024-004403PT-141 (Bremelanotide)ASYASY-{CAT}-2723Medutest2024-Q399.484.14Buyer-sourced0PASS
SupplierRecordsMedian purity
SWB2n<3
KP2n<3
ASY2n<3
WWB1n<3
HJ1n<3
FGP1n<3
WXT1n<3
SSA1n<3
Section 3

Annotations

Signed technical comments on records. The index does not moderate annotations for agreement with its own arithmetic, and several of these disagree with it. Where a handle has made the same point on several records, one instance is shown and the rest are reachable from the records themselves.

AX-2026-042711
Automated filling on a low-mass vial has a real tolerance and it is wider than most labels imply. A ±10 % index tolerance is generous against pharmacopoeial content uniformity and this record sits outside even that.
AX-2026-043027
Gravimetric fill checks in this index show under-fill outnumbering over-fill by roughly three to one. That asymmetry is a fill-target convention rather than a random process, and it is entirely legible once content is measured.
AX-2025-020072
Purity at 97.36 % and recovery at 86.0 % are independent findings. High purity and low recovery is a formulation and fill result, not a synthesis one.
AX-2024-004557
Thanks — that is the detail I was missing.

Showing 5 distinct comments of 6 annotations by this handle.