Purity by RP-HPLC, wavelength stated, stability-indicating method named. Determination is reproducible from the certificate alone. Contributor declares no interest beyond the transaction.
WXT — WuXi TIDES (WuXi AppTec Testing Division)
Wuxi, CN · established 2002. The index holds 301 assay reports across 51 batches and 26 compounds, contributed by 6 laboratories. Every figure below is computed from those records and from nothing else.
Where WXT sells
WuXi TIDES (WuXi AppTec Testing Division) sells from its own storefront. The link is marked nofollow and sponsored: it exists so the figures on this scorecard can be read against what the supplier itself publishes. The index is paid nothing for it and a link is not an assessment.
Every figure above describes lots the index has seen. It says nothing about the lot you are offered, and the only check that does is the one on the certificate against the vial.
Identification
Business facts, held constant across the index and not derived from the data. The index sells nothing and takes no supplier payment for placement; the storefront link below is marked nofollow and sponsored so a record can be checked against the seller, and is not a recommendation.
- Legal name
- WuXi TIDES (WuXi AppTec Testing Division)
- Short code in this index
- WXT
- Also known as
- WXT · WXT Biotech · WuXi TIDES (WuXi AppTec Testing Division)
- Domain
- wuxitides.net →
- City
- Wuxi
- Region
- Wuxi
- Country
- CN
- Established
- 2002
- First record in index
- 10 Jan 2024
- Most recent record
- 15 Oct 2026
Dispatch and regional stock
Counted from the chain-of-custody line on this supplier's own records, which names the route each vial travelled to the laboratory, and from the on-record reviews below. The index has no sight of any supplier's warehouse network and publishes none.
| Route to the laboratory | Records | Share |
|---|---|---|
| Domestic warehouse despatch | 43 | 14.3% |
| Retail purchase, shipped to the buyer | 150 | 49.8% |
| Retail purchase via a third-party forwarder | 43 | 14.3% |
| Supplier despatch direct to the laboratory | 46 | 15.3% |
| Laboratory retained-sample archive | 19 | 6.3% |
Every record here carries a chain-of-custody line and that line names the route the vial travelled. Of the 301 WXT records the index holds, 43 reached the contributing laboratory from a domestic warehouse rather than as a cross-border consignment, covering 17 of the 26 compounds WXT is represented by here — Semaglutide, Tirzepatide, BPC-157, MOTS-c, PT-141 (Bremelanotide), CJC-1295 (no DAC) and 11 further compounds. Those are the WXT lines this index has actually seen arrive from regional stock, and they are a count of consignments rather than a stock listing: a line missing from them may simply never have been submitted for assay.
One contributor on the record below documents WXT stock held in Poland, with a transit of 6 working days against a quoted 6. Poland is the only regional stock location named anywhere in WXT's record here, and one consignment described by one buyer is exactly that. It is not a warehouse list and the index has not verified it.
The index measures nothing about lead time — it assays material, it does not buy it. What it has is WXT's own reviewers: 2 of the 26 on-record reviews state a quoted window and what happened against it, and 1 of them describes same-day dispatch. Where WXT despatched a sample direct to a laboratory, the courier leg ran a median 7 days across 46 such consignments — that is a transit time the index can see, and it is not the same thing as a lead time. The reviews are reproduced in full in Block 11.
Headline statistics
Each figure carries the n it was computed from. The n= badge next to a statistic is the number of records it was computed from. Below n=8 the badge is amber. Below n=3 the statistic is suppressed and the individual values are shown instead.
Reproducibility across independent tests of one lot
Where the same physical lot was assayed more than once, the spread between those results is a property of the material and the fill, not of the market. It is the rarest and most informative statistic on this page, and it exists only for lots someone tested twice.
Across the 38 WXT lots in the index with three or more independent assays, the median spread between the highest and lowest purity result on one lot is 1.00 pp. Interpreting that number requires the laboratory repeatability figures: the best contributing laboratory here repeats to 0.16 pp and the worst to 0.34 pp, so a within-lot spread under about 0.5 pp is indistinguishable from measurement noise and a spread above 1 pp is a statement about the material.
Supplier certificate against independent measurement
The supplier's own COA purity figure for a lot, minus the median of the index's independent observations of the same physical lot. Positive means the certificate reads higher than the measurement. Rule AX-R05 fires above 1.5 pp.
Provenance — where the tested material came from
Supplier-supplied samples are weaker evidence than independently purchased ones, because the supplier chose the vial. The index measures the size of that effect rather than assuming it.
Documentation completeness
The score is not an opinion about paperwork. Each component is the share of WXT batches in the index whose certificate carries that field, weighted as set out on the scoring rubric.
| Certificate field | Batches carrying it | Rubric weight | |
|---|---|---|---|
| Purity figure stated | 100% | 25 points | |
| Analytical method stated (column, gradient, wavelength) | 61% | 25 points | |
| Peptide content stated | 59% | 20 points | |
| Endotoxin stated | 39% | 15 points | |
| Named impurities rather than a total | 23% | 15 points |
Coverage by compound
The delta column is this supplier's median minus the index-wide median for the same compound, which is the only comparison worth making: comparing a supplier's aggregate against another supplier's aggregate compares their product mixes as much as their process control.
| Compound | Class | Reports | Median % | Index median % | Δ (pp) | Index spec | Pass % |
|---|---|---|---|---|---|---|---|
| Semaglutide | Incretin | 53 | 97.90 | 98.89 | -0.99 | 97.0 | 96 |
| BPC-157 | Tissue-repair | 34 | 98.67 | 99.16 | -0.49 | 98.0 | 79 |
| PT-141 (Bremelanotide) | Melanocortin-receptor | 27 | 98.69 | 99.38 | -0.69 | 98.5 | 67 |
| L-Glutathione (reduced) | Short | 24 | 98.07 | 99.33 | -1.26 | 98.5 | 21 |
| Tirzepatide | Incretin | 24 | 98.59 | 98.55 | +0.04 | 97.0 | 100 |
| MK-677 (Ibutamoren mesylate) | Non-peptide | 17 | 99.29 | 99.49 | -0.20 | 98.5 | 100 |
| MOTS-c | Metabolic | 13 | 98.46 | 99.13 | -0.67 | 98.0 | 62 |
| Leuprolide | Hypothalamic | 12 | 98.83 | 99.28 | -0.45 | 98.5 | 92 |
| CJC-1295 (no DAC) | Growth-hormone | 12 | 98.63 | 99.09 | -0.47 | 98.0 | 83 |
| GHRP-2 | Growth-hormone | 11 | 98.57 | 99.28 | -0.72 | 99.0 | 18 |
| Survodutide | Incretin | 10 | 97.87 | 98.38 | -0.51 | 96.5 | 100 |
| 5-Amino-1MQ | Non-peptide | 9 | 98.71 | 99.45 | -0.75 | 98.0 | 89 |
| CJC-1295 with DAC | Growth-hormone | 8 | 97.20 | 98.95 | -1.75 | 97.5 | 38 |
| N-Acetyl Semax Amide | Neuroactive | 7 n=7 | 98.40 | 99.35 | -0.95 | 98.5 | 43 |
| IGF-1 LR3 | Growth-hormone | 6 n=6 | 96.97 | 98.28 | -1.31 | 95.0 | 100 |
| TB-500 | Tissue-repair | 5 n=5 | 97.85 | 99.53 | -1.68 | 98.5 | 0 |
| Enclomiphene citrate | Non-peptide | 5 n=5 | 99.08 | 99.44 | -0.36 | 98.5 | 100 |
| GHRP-6 | Growth-hormone | 5 n=5 | 99.04 | 99.54 | -0.50 | 99.0 | 80 |
| Sermorelin | Growth-hormone | 4 n=4 | 98.94 | 99.06 | -0.12 | 98.0 | 75 |
| ARA-290 | Tissue-repair | 4 n=4 | 99.23 | 99.42 | -0.19 | 98.0 | 100 |
| Semax | Neuroactive | 4 n=4 | 98.69 | 99.46 | -0.77 | 98.5 | 100 |
| Tesamorelin | Growth-hormone | 2 n=2 | n<3 | 98.29 | — | 97.0 | 50 |
| Selank | Neuroactive | 2 n=2 | n<3 | 99.59 | — | 99.0 | 100 |
| Melanotan II | Melanocortin-receptor | 1 n=1 | n<3 | 99.42 | — | 98.5 | 100 |
| Liraglutide | Incretin | 1 n=1 | n<3 | 99.00 | — | 97.5 | 0 |
| Ipamorelin | Growth-hormone | 1 n=1 | n<3 | 99.47 | — | 99.0 | 100 |
Full per-compound breakdown with distributions and caveats →
Quarterly trend
Submission volume is not market share and a quarterly median is not a trend unless the compound mix held still. Both caveats apply to every row below.
Median purity by quarter
Quarters with fewer than two purity records are gaps in the line rather than zeroes.
Coverage growth
Records added per quarter. Growth here is index coverage, not supplier volume.
| Quarter | Batches | Reports | Median purity | Range | Flagged |
|---|---|---|---|---|---|
| 2024-Q1 | 1 | 2 | n<3 | 97.76–97.85 | 1 |
| 2024-Q2 | 1 | 4 | 98.69 | 98.55–98.91 | 1 |
| 2024-Q3 | 3 | 20 | 98.85 | 97.35–99.79 | 2 |
| 2024-Q4 | 4 | 19 | 99.04 | 98.08–99.35 | 9 |
| 2025-Q1 | 6 | 39 | 98.55 | 96.83–99.72 | 10 |
| 2025-Q2 | 5 | 36 | 98.51 | 97.66–99.93 | 17 |
| 2025-Q3 | 9 | 47 | 98.91 | 96.78–99.80 | 10 |
| 2025-Q4 | 6 | 40 | 98.16 | 97.06–99.93 | 1 |
| 2026-Q1 | 5 | 19 | 98.38 | 97.17–99.17 | 6 |
| 2026-Q2 | 7 | 38 | 98.10 | 97.20–99.86 | 11 |
| 2026-Q3 | 4 | 37 | 97.97 | 96.58–99.41 | 16 |
Which laboratory produced these numbers
Laboratories disagree with each other by a measured amount. A supplier tested mostly by one laboratory carries that laboratory's offset in its aggregate, and the adjusted column removes it.
| Laboratory | Reports | Median purity | Lab bias (pp) | Bias-adjusted |
|---|---|---|---|---|
| Janoshik | 140 | 98.45 | +0.00 | 98.45 |
| PeptideMeter | 45 | 98.55 | -0.05 | 98.60 |
| Medutest | 38 | 98.53 | +0.08 | 98.45 |
| VendorInvestigate | 33 | 98.19 | -0.11 | 98.30 |
| Nordanalyt | 27 | 98.55 | +0.02 | 98.53 |
| Kestrel | 18 | 98.78 | +0.24 | 98.54 |
Bias figures are estimated from paired same-lot comparisons and are published with their confidence intervals on inter-lab agreement.
What this data does and does not show
On-the-record reviews 26
Reviews are signed statements from index contributors about their own testing of this supplier's material. They are opinions attached to evidence, and they are not used in any statistic on this page.
Single lot identifier across the whole consignment. Intra-consignment comparison valid. Vial-to-vial mass variation under 2%.
Storage condition for the stability statement stated on the certificate. No further comment.
Blind submission of TB-500 5 mg to Medutest, origin withheld. 98.5% against 98.7% declared. Nothing unsecured in the consignment.
Published stock status matched availability. Same-day dispatch. Identifier matches across vial, certificate and commercial documentation.
Lot-specific certificate attached at despatch, issued against the code on the vial. Nothing needed requesting.
Retention time assigned to the principal peak, printed.
Water content by Karl Fischer, method named. Vial-to-vial mass variation under 2%.
3 orders, 14 months. No substitution, no reformulation, no post-payment unavailability. Reorder at 18 months within 0.1 points of the original.
Certificate carries peptide content stated separately from purity. Complete against the index minimum data set at first issue. Nothing unsecured in the consignment. No adverse observation.
Labelling printed, lot and date legible on every unit examined. Independent verification of individual lots still required.
Custom synthesis delivered 3 days inside the quoted schedule at the specified purity. Declared and independent figures differ by less than repeatability.
Counter-ion identity and content answered quantitatively, one working day. Gradient and column chemistry stated.
Declared figure not adjusted upward between certificate and commercial documentation. Vial-to-vial mass variation under 2%.
Twelve orders, water content on every certificate with the method stated. Contributor declares no interest beyond the transaction.
Repeat determination at 10 months: 98.2%. Original: 98.2%. No drift detected in this sample.
Related-substances table itemised by impurity with assigned retention times. Not aggregated.
Packing: the invoice sealed in its own sleeve rather than loose against the vials.
Documentation complete at first issue. No supplementary request raised. Gradient and column chemistry stated.
Lot WXT-25-287 submitted to PeptideMeter. Declared 97.4%, reported 97.7%. Delta inside method repeatability.
Transit 6 days from stock held in Poland against a quoted 6. Customs documentation correct at first presentation.
Orthogonal identity present: mass spectrometry alongside the chromatographic determination. n=1, declared as n=1.
Tracking live from despatch and accurate at every scan. Documentation complete at first issue. Identifier matches across vial, certificate and commercial documentation.
Fill uniformity: 6 units weighed against declared fill, all within 2%. Declared and independent figures differ by less than repeatability. No adverse observation.
Residual-solvent screen included unrequested. Gradient and column chemistry stated.
Every vial in the box sound on inspection: flange, crimp and cake. Vial-to-vial mass variation under 2%. Subsequent orders placed with the same supplier.
Most recent records
Contributor annotations on WXT records 509
Annotations are this index's only discussion surface: signed technical comments attached to a specific record by a named contributor. They are not moderated for agreement with the index's own arithmetic. The most recent on WXT material are below, each linked to the record it sits on.
Every annotation the index holds on WXT material sits on its own record; the full set is reachable from the record listing and from each contributor's page. To read them against what WXT itself publishes, open wuxitides.net → alongside.
Where to buy WXT
WuXi TIDES (WuXi AppTec Testing Division) sells direct from wuxitides.net. Everything on this page describes lots the index has already seen; the certificate that matters is the one that arrives with the vial you order, and the lot code on it should match the vial. Ask for the lot-specific document rather than the batch-level summary, and ask for the integration report if you intend to reconcile the figure yourself.
Go to the WXT store at wuxitides.net →
Marked nofollow and sponsored. The index is paid nothing for it, takes no commission, and a link is not an assessment. Research compounds. Not medical advice. Nothing on this site is a safety assessment and nothing on it is approved for human use.