AX-2025-021110

L-Glutathione (reduced) · 1500 mg declared · Bachem Holding (Suzhou) Co., Ltd. · lot BCH-2502-Y5639

FAILMETHOD LIMITED
Report ID
AX-2025-021110
Compound
L-Glutathione (reduced)
Compound class
Short bioregulator peptides
Supplier
BCH — Bachem Holding (Suzhou) Co., Ltd.
Batch / lot
BCH-2502-Y5639
Declared label claim
1500mg
Laboratory
Janoshik Analytical
Assay date
26 Jun 2025
Submitted
01 Jul 2025
Quarter
2025-Q2
Submitter
la.haddad
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the short bioregulator peptides class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 30 min gradient, 214 nm97.88% area≥ 98.5FAIL
Total impuritiesRP-HPLC, sum of reported peaks2.12% area≤ 1.5FAIL
Largest single impurityRP-HPLC — cysteinyl-glycine (−129 Da)0.98% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula307.0838DaNOT TESTED
Identity — observed monoisotopic massLC-MS, high resolution (ESI-TOF/QTOF)307.0842DaNOT TESTED
Mass accuracyobserved vs theoretical+1.4ppm± 20PASS
Peptide contentnot ordered on this submissionnot determinedrequired to check label claimNOT TESTED
Water contentKarl Fischer, coulometric, duplicate9.15%≤ 12.0PASS
Counter-ionno ionisable counter-ion expectedN/Anot applicableNOT TESTED
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.55%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitymembrane filtration, USP <71>, 14 dNo growth at 14 dno growthPASS
Appearancevisual, diffuse light, black and white backgroundOff-white lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration6.522.5 – 8.0PASS
Retention time (observed)RP-HPLC, 30 min gradient4.33min4.28 ± 0.20 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.230.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²42,825≥ 20,000PASS
Resolution to nearest impurityvs S-sulfonate adduct (+80 Da)1.63no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

0485797131457019426 L-Glutathione (reduced)4.33 min · 97.88 % 4.09 same trace · ×50 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 05101520253035 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 30 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 42,825, and skew follows the reported asymmetry factor of 1.23. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.98 % impurity against a 97.88 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1L-Glutathione (reduced) — main peak4.334,757,27197.88
2cysteinyl-glycine (−129 Da)4.0947,6310.98-129.043
3glutathione disulfide (GSSG, +305 Da)4.8536,4520.75+304.984
4γ-Glu-Cys (−57 Da)4.159,7210.20-57.021
5S-sulfonate adduct (+80 Da)4.199,2350.19+79.957
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 307.0838 Da, computed from C10H17N3O6S. All ppm figures on this site are against monoisotopic values — see why that matters.

0255075100275300325350375400 [M+1H]1+308.09 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, high-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 307.0842 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
1+308.0911308.09150.0004100.0
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)97.8497.88divergence -0.04 pp vs batch median
Total impurities (% area)not stated2.12
Largest single impurity (% area)not stated0.98
Water (%)not stated9.15
Counter-ion (%)not statedN/A
Peptide content (%w/w)91.7not determined
Endotoxin (EU/mg)not statednot determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → submitter (−20 °C, 8 d) → laboratory (courier, dry ice, 3 d) → assay.
Assay date
26 Jun 2025
Submitted to the index
01 Jul 2025
Laboratory
Janoshik Analytical, Ostrava, Czechia
Method basis
30 min gradient · high-resolution MS
Verification status
METHOD LIMITED
Section 6

Annotations 2

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

retest_date
Retail certificates in this index carry a retest date more often than they used to. It is the field that turns a release figure into a statement about the material over time.
stopper_seal
A nitrogen headspace suppresses re-oxidation and scrambling in the solid state. Neither headspace composition nor closure integrity is on any certificate the index holds.
Section 7

Related records

Same batch — lot BCH-2502-Y5639 n=1

This is the only report on this lot. One report is not a batch characterisation.

Other recent L-Glutathione (reduced) records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043429WXTWXT-2605-B3833Nordanalyt2026-Q398.486.5896.9Supplier-supplied1FAIL
AX-2026-043424WXTWXT-2605-B3833PeptideMeter2026-Q398.376.86Buyer-sourced0FAIL
AX-2026-043166GL BiochemGLBI-2606-S7352Janoshik2026-Q399.018.84105.4Laboratory-retained1MARGINAL
AX-2026-043423WXTWXT-2605-B3833Janoshik2026-Q397.866.6693.4Buyer-sourced0FAIL
AX-2026-043426WXTWXT-2605-B3833Kestrel2026-Q398.836.32Supplier-supplied1MARGINAL
AX-2026-043425WXTWXT-2605-B3833Janoshik2026-Q398.776.35Supplier-supplied1MARGINAL
AX-2026-043431WXTWXT-2605-B3833Nordanalyt2026-Q397.946.18Buyer-sourced0FAIL
AX-2026-043427WXTWXT-2605-B3833Medutest2026-Q397.676.08Buyer-sourced1FAIL
Other recent BCH records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043445BPC-157BCH-2603-G4350Nordanalyt2026-Q398.424.8793.6Buyer-sourced1MARGINAL
AX-2026-043440BPC-157BCH-2603-G4350VendorInvestigate2026-Q398.614.11Buyer-sourced1MARGINAL
AX-2026-043442BPC-157BCH-2603-G4350Janoshik2026-Q398.654.78Buyer-sourced1MARGINAL
AX-2026-043471CJC-1295 with DACBCH-2607-H5235Janoshik2026-Q397.465.48Buyer-sourced1FAIL
AX-2026-043477CJC-1295 with DACBCH-2607-H5235VendorInvestigate2026-Q397.625.3299.6Buyer-sourced1MARGINAL
AX-2026-043449BPC-157BCH-2603-G4350Kestrel2026-Q399.744.9291.3Supplier-supplied2MARGINAL
AX-2026-043448BPC-157BCH-2603-G4350Janoshik2026-Q398.554.69106.9Buyer-sourced1MARGINAL
AX-2026-043470CJC-1295 with DACBCH-2607-H5235Janoshik2026-Q397.766.1199.3Supplier-supplied1MARGINAL