AssayIndex

AX-2025-019437

CJC-1295 with DAC · 2 mg declared · Guangzhou JEEP Biotechnology Co., Ltd. · lot JEEP-2509-P7991

FAILIDENTITY CONSISTENT
Report ID
AX-2025-019437
Compound
CJC-1295 with DAC
Compound class
Growth-hormone axis peptides
Supplier
JEEP — Guangzhou JEEP Biotechnology Co., Ltd.
Batch / lot
JEEP-2509-P7991
Declared label claim
2mg
Laboratory
Medutest
Assay date
22 Dec 2025
Submitted
26 Dec 2025
Quarter
2025-Q4
Submitter
Contributor #F-2358
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the growth-hormone axis peptides class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 25 min gradient, 214 nm98.77% area≥ 97.5PASS
Total impuritiesRP-HPLC, sum of reported peaks1.23% area≤ 2.5PASS
Largest single impurityRP-HPLC — deamidated (+1 Da)0.84% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula3644.9748DaNOT TESTED
Identity — observed monoisotopic massLC-MS, unit resolution (single quadrupole)3644.9092DaNOT TESTED
Mass accuracyobserved vs theoretical-18.0ppm± 15FAIL
Peptide contentnot ordered on this submissionnot determinedrequired to check label claimNOT TESTED
Water contentKarl Fischer, coulometric, duplicate3.73%≤ 9.0PASS
Counter-ion (acetate)anion-exchange ion chromatography5.06%≤ 12.0PASS
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.69%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration5.482.5 – 8.0PASS
Retention time (observed)RP-HPLC, 25 min gradient12.54min12.38 ± 0.35 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.060.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²54,176≥ 20,000PASS
Resolution to nearest impurityvs deamidated (+1 Da)0.98no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

02060412161818241 CJC-1295 with DAC12.54 min · 98.77 % 12.3214.56 same trace · ×50 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 0481216202428 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 25 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 54,176, and skew follows the reported asymmetry factor of 1.06. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.84 % impurity against a 98.77 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1CJC-1295 with DAC — main peak12.544,800,52898.77
2deamidated (+1 Da)12.3240,8270.84+0.984
3hydrolysed maleimide (+18 Da)12.027,7760.16+18.011
4mod-GRF (1-29) (−279 Da)11.077,7760.16-279.235
5maleimide dimer14.563,4020.07+3644.975
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 3644.9748 Da, computed from C165H269N47O46. All ppm figures on this site are against monoisotopic values — see why that matters.

025507510057580010251250147517001925 [M+3H]3+1215.98[M+4H]4+912.23[M+2H]2+1823.46 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, unit-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 3644.9092 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
5+730.0022729.9891-0.01318.8
4+912.2510912.2346-0.016455.6
3+1215.99891215.9770-0.0219100.0
2+1823.49471823.4619-0.032853.8
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)98.9998.77divergence +0.30 pp vs batch median
Total impurities (% area)0.661.23
Largest single impurity (% area)0.370.84
Water (%)3.03.73
Counter-ion (%)5.45.06
Peptide content (%w/w)91.0not determined
Endotoxin (EU/mg)not statednot determined
Method stated on certificateNOno method section — the result cannot be reconciled against any other
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → submitter (ambient, 7 d) → laboratory (courier, cold pack, 9 d) → assay.
Assay date
22 Dec 2025
Submitted to the index
26 Dec 2025
Laboratory
Medutest, Ljubljana, Slovenia
Method basis
25 min gradient · unit-resolution MS
Verification status
IDENTITY CONSISTENT
Section 6

Annotations 4

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

mass_defect
If the assignment is shifted by one charge state the error resolves. Confirm the deconvolution before treating -18.0 ppm as a real discrepancy about the material.
ppm_error
The distribution of ppm error by instrument class in this index is wide enough that a single figure like -18.0 ppm carries little on its own. What carries is whether the same instrument produced similar excursions on adjacent runs, and the laboratory page has that.
sodium_adduct
Mass-defect reasoning narrows this quickly. Very few plausible modifications of CJC-1295 with DAC would produce a shift in the direction and magnitude observed, and the ones that would are all in the named-impurity table.
ms_confirm
The purity, water and counter-ion figures on this record stand regardless of the mass question. Only the identity limb is affected, and the status field says exactly that.
Section 7

Related records

Same batch — lot JEEP-2509-P7991 n=3

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-019435JEEP-2509-P7991Janoshik2025-Q498.693.88104.0Buyer-sourced1MARGINAL
AX-2025-019436JEEP-2509-P7991Janoshik2025-Q498.423.8191.1Buyer-sourced1MARGINAL
Other recent CJC-1295 with DAC records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041681TFSTFS-{CAT}-9675PeptideMeter2026-Q398.823.67Buyer-sourced0PASS
AX-2026-041867SinoPepSNP-2607-C3886Janoshik2026-Q399.245.12Laboratory-retained1FAIL
AX-2026-041682TFSTFS-{CAT}-9675Nordanalyt2026-Q398.943.24Buyer-sourced0PASS
AX-2026-041683TFSTFS-{CAT}-9675Medutest2026-Q398.683.4697.0Buyer-sourced0PASS
AX-2026-043471BCHBCH-2607-H5235Janoshik2026-Q397.465.48Buyer-sourced1FAIL
AX-2026-043477BCHBCH-2607-H5235VendorInvestigate2026-Q397.625.3299.6Buyer-sourced1MARGINAL
AX-2026-043470BCHBCH-2607-H5235Janoshik2026-Q397.766.1199.3Supplier-supplied1MARGINAL
AX-2026-043478BCHBCH-2607-H5235PeptideMeter2026-Q397.635.4290.1Buyer-sourced1MARGINAL
Other recent JEEP records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042177HexarelinJEEP-2608-Y9547Janoshik2026-Q399.903.42Buyer-sourced0PASS
AX-2026-042162SemaglutideJEEP-2607-X9091Janoshik2026-Q398.983.46Laboratory-retained1MARGINAL
AX-2026-042127TB-500JEEP-2602-V8614Medutest2026-Q399.683.55Buyer-sourced1FAIL
AX-2026-042123TB-500JEEP-2602-V8614PeptideMeter2026-Q399.933.80Buyer-sourced0PASS
AX-2026-042124TB-500JEEP-2602-V8614PeptideMeter2026-Q399.913.37104.9Buyer-sourced0PASS
AX-2026-042178HexarelinJEEP-2608-Y9547VendorInvestigate2026-Q399.684.03Buyer-sourced0PASS
AX-2026-042163SemaglutideJEEP-2607-X9091Nordanalyt2026-Q399.464.52Buyer-sourced1MARGINAL
AX-2026-042122TB-500JEEP-2602-V8614PeptideMeter2026-Q399.603.5897.0Buyer-sourced0PASS