AssayIndex
Supplier scorecard

JEEP — Guangzhou JEEP Biotechnology Co., Ltd.

Guangzhou, CN. The index holds 230 assay reports across 38 batches and 24 compounds, contributed by 6 laboratories. Every figure below is computed from those records and from nothing else.

230 reports38 batchesmedian purity 99.37 %documentation 88/100

Where JEEP sells

Guangzhou JEEP Biotechnology Co., Ltd. sells from its own storefront. The link is marked nofollow and sponsored: it exists so the figures on this scorecard can be read against what the supplier itself publishes. The index is paid nothing for it and a link is not an assessment.

Visit JEEP at jeepbio.com →

Every figure above describes lots the index has seen. It says nothing about the lot you are offered, and the only check that does is the one on the certificate against the vial.

Block 1

Identification

Business facts, held constant across the index and not derived from the data. The index sells nothing and takes no supplier payment for placement; the storefront link below is marked nofollow and sponsored so a record can be checked against the seller, and is not a recommendation.

Legal name
Guangzhou JEEP Biotechnology Co., Ltd.
Short code in this index
JEEP
Also known as
JEEP · JEEP Peptides · JEEP Bio
City
Guangzhou
Region
Guangdong
Country
CN
Established
not stated
First record in index
12 Jan 2024
Most recent record
11 Oct 2026
Block 1b

Dispatch and regional stock

Counted from the chain-of-custody line on this supplier's own records, which names the route each vial travelled to the laboratory, and from the on-record reviews below. The index has no sight of any supplier's warehouse network and publishes none.

Domestic-warehouse route 17.8% n=230
Retail, shipped to the buyer 72.6% n=230
Direct to the laboratory 2.2% n=230
Median courier leg, direct despatch 7d n=5
Route to the laboratoryRecordsShare
Domestic warehouse despatch4117.8%
Retail purchase, shipped to the buyer13357.8%
Retail purchase via a third-party forwarder3414.8%
Supplier despatch direct to the laboratory52.2%
Laboratory retained-sample archive177.4%

Every record here carries a chain-of-custody line and that line names the route the vial travelled. Of the 230 JEEP records the index holds, 41 reached the contributing laboratory from a domestic warehouse rather than as a cross-border consignment, covering 16 of the 24 compounds JEEP is represented by here — Retatrutide, Semax, BPC-157, TB-500, N-Acetyl Semax Amide, PT-141 (Bremelanotide) and 10 further compounds. Those are the JEEP lines this index has actually seen arrive from regional stock, and they are a count of consignments rather than a stock listing: a line missing from them may simply never have been submitted for assay.

No contributor to this index has named a regional stock location for JEEP. 41 of its records nevertheless arrived by a domestic-warehouse route, so stock is held somewhere; the index does not know where and will not guess.

The index measures nothing about lead time — it assays material, it does not buy it. What it has is JEEP's own reviewers: 4 of the 26 on-record reviews state a quoted window and what happened against it, and 1 of them describes same-day dispatch. Where JEEP despatched a sample direct to a laboratory, the courier leg ran a median 7 days across 5 such consignments — that is a transit time the index can see, and it is not the same thing as a lead time. The reviews are reproduced in full in Block 11.

Block 2

Headline statistics

Each figure carries the n it was computed from. The n= badge next to a statistic is the number of records it was computed from. Below n=8 the badge is amber. Below n=3 the statistic is suppressed and the individual values are shown instead.

Median purity 99.37% n=230
Interquartile range 0.70pp n=230
10th percentile 98.56% n=230
Pass rate vs index spec 96.5% n=230
Median recovery vs claim 98.2% n=123
Median water 4.92% n=230
Median |mass error| 2.3ppm n=203
Records carrying a flag 27.0% n=230
014284292.093.094.095.096.097.098.099.0100.092.00–92.25 %: n=092.25–92.50 %: n=092.50–92.75 %: n=092.75–93.00 %: n=093.00–93.25 %: n=093.25–93.50 %: n=093.50–93.75 %: n=093.75–94.00 %: n=094.00–94.25 %: n=094.25–94.50 %: n=094.50–94.75 %: n=094.75–95.00 %: n=095.00–95.25 %: n=095.25–95.50 %: n=095.50–95.75 %: n=095.75–96.00 %: n=096.00–96.25 %: n=096.25–96.50 %: n=096.50–96.75 %: n=096.75–97.00 %: n=097.00–97.25 %: n=097.25–97.50 %: n=097.50–97.75 %: n=097.75–98.00 %: n=798.00–98.25 %: n=398.25–98.50 %: n=1198.50–98.75 %: n=1898.75–99.00 %: n=1999.00–99.25 %: n=4199.25–99.50 %: n=3899.50–99.75 %: n=4499.75–100.00 %: n=49median 99.37 Purity (% area) Reports
Figure 1. Purity distribution for all 230 JEEP records carrying a purity figure. Domain fixed at 92–100 % area and bin width 0.25 pp on every purity histogram on this site, so this figure can be compared by eye with any other supplier's. Dashed line is the JEEP median, 99.37 %; the index median is 99.08 %.
Block 3

Reproducibility across independent tests of one lot

Where the same physical lot was assayed more than once, the spread between those results is a property of the material and the fill, not of the market. It is the rarest and most informative statistic on this page, and it exists only for lots someone tested twice.

Median within-batch spread 0.63pp n=28
Index median spread 0.67pp n=28
Lots tested 3+ times 28 n=38

Across the 28 JEEP lots in the index with three or more independent assays, the median spread between the highest and lowest purity result on one lot is 0.63 pp. Interpreting that number requires the laboratory repeatability figures: the best contributing laboratory here repeats to 0.16 pp and the worst to 0.34 pp, so a within-lot spread under about 0.5 pp is indistinguishable from measurement noise and a spread above 1 pp is a statement about the material.

Block 4

Supplier certificate against independent measurement

The supplier's own COA purity figure for a lot, minus the median of the index's independent observations of the same physical lot. Positive means the certificate reads higher than the measurement. Rule AX-R05 fires above 1.5 pp.

Median COA divergence +0.03pp n=38
Index median divergence +0.06pp n=28
Divergences in the supplier's favour 53% n=38
Divergences beyond 1 pp 0% n=38
Block 5

Provenance — where the tested material came from

Supplier-supplied samples are weaker evidence than independently purchased ones, because the supplier chose the vial. The index measures the size of that effect rather than assuming it.

Buyer-sourced median 99.35% n=208
Supplier-supplied median 99.83% n=5
Supplier-supplied share of records 2.2% n=230
97.698.098.498.899.399.7100.1Buyer-sourcedBuyer-sourced: Q1 98.97, median 99.35, Q3 99.68, n=208outlier 97.75outlier 97.78outlier 97.84outlier 97.85outlier 97.88n=208Supplier-suppliedSupplier-supplied: Q1 99.74, median 99.83, Q3 99.93, n=5outlier 98.63n=5Laboratory-retainedLaboratory-retained: Q1 99.23, median 99.59, Q3 99.81, n=17n=17 Purity (% area)
Figure 2. JEEP purity by sample provenance. Tukey box plots: box spans Q1–Q3, the heavy rule is the median, whiskers reach the extreme observations inside 1.5 IQR of the box, and points outside the fences are plotted individually. The vertical line is the JEEP overall median. Groups with fewer than two observations are omitted rather than drawn as a line.
Block 6

Documentation completeness

The score is not an opinion about paperwork. Each component is the share of JEEP batches in the index whose certificate carries that field, weighted as set out on the scoring rubric.

Documentation score 88/100 n=38
Index median score 85/100 n=28
Certificate fieldBatches carrying itRubric weight
Purity figure stated100%25 points
Analytical method stated (column, gradient, wavelength)63%25 points
Peptide content stated74%20 points
Endotoxin stated42%15 points
Named impurities rather than a total63%15 points
Block 7

Coverage by compound

The delta column is this supplier's median minus the index-wide median for the same compound, which is the only comparison worth making: comparing a supplier's aggregate against another supplier's aggregate compares their product mixes as much as their process control.

CompoundClassReportsMedian %Index median %Δ (pp)Index specPass %
BPC-157Tissue-repair2999.0999.16-0.0798.0100
SemaglutideIncretin2599.2498.89+0.3597.0100
TB-500Tissue-repair2199.6899.53+0.1598.5100
TirzepatideIncretin1998.8698.55+0.3197.0100
SemaxNeuroactive1899.5399.46+0.0798.5100
SS-31 (Elamipretide)Metabolic1499.6699.53+0.1398.5100
Melanotan IIMelanocortin-receptor1399.5099.42+0.0898.5100
RetatrutideIncretin1397.9298.37-0.4596.5100
GHRP-6Growth-hormone1399.4299.54-0.1299.0100
PT-141 (Bremelanotide)Melanocortin-receptor1298.4499.38-0.9498.533
N-Acetyl Semax AmideNeuroactive1099.9399.35+0.5898.5100
5-Amino-1MQNon-peptide999.9399.45+0.4898.0100
LiraglutideIncretin6 n=699.0999.00+0.0997.5100
CJC-1295 with DACGrowth-hormone4 n=498.7398.95-0.2297.5100
MOTS-cMetabolic4 n=499.5699.13+0.4398.0100
KPVTissue-repair4 n=499.8599.64+0.2199.0100
ARA-290Tissue-repair3 n=399.2499.42-0.1898.0100
LeuprolideHypothalamic3 n=399.3299.28+0.0498.5100
HexarelinGrowth-hormone2 n=2n<399.5999.0100
ThymulinTissue-repair2 n=2n<399.2798.0100
GHRP-2Growth-hormone2 n=2n<399.2899.0100
EpitalonShort2 n=2n<399.5699.0100
CagrilintideIncretin1 n=1n<398.6996.5100
PinealonShort1 n=1n<399.9399.0100

Full per-compound breakdown with distributions and caveats →

97.698.098.498.899.399.7100.1BPC-157BPC-157: Q1 98.85, median 99.09, Q3 99.24, n=29n=29SemaglutideSemaglutide: Q1 99.03, median 99.24, Q3 99.38, n=25outlier 99.93n=25TB-500TB-500: Q1 99.47, median 99.68, Q3 99.93, n=21n=21TirzepatideTirzepatide: Q1 98.65, median 98.86, Q3 99.12, n=19n=19SemaxSemax: Q1 99.49, median 99.53, Q3 99.72, n=18outlier 99.07n=18SS-31 (Elamipretide)SS-31 (Elamipretide): Q1 99.22, median 99.66, Q3 99.69, n=14n=14Melanotan IIMelanotan II: Q1 99.40, median 99.50, Q3 99.72, n=13n=13RetatrutideRetatrutide: Q1 97.85, median 97.92, Q3 98.42, n=13n=13GHRP-6GHRP-6: Q1 99.33, median 99.42, Q3 99.50, n=13outlier 99.04n=13PT-141 (Bremelanotide)PT-141 (Bremelanotide): Q1 98.31, median 98.44, Q3 98.72, n=12n=12N-Acetyl Semax AmideN-Acetyl Semax Amide: Q1 99.83, median 99.93, Q3 99.93, n=10n=105-Amino-1MQ5-Amino-1MQ: Q1 99.78, median 99.93, Q3 99.93, n=9outlier 99.35n=9LiraglutideLiraglutide: Q1 99.04, median 99.09, Q3 99.26, n=6outlier 98.71n=6CJC-1295 with DACCJC-1295 with DAC: Q1 98.62, median 98.73, Q3 98.96, n=4outlier 99.52n=4 Purity (% area)
Figure 3. JEEP purity by compound, for the 14 compounds with at least four JEEP records. Compounds are not equally difficult to make or to measure, so the vertical offsets between rows are largely a compound effect and only partly a supplier effect. Compare a row against the same compound on another supplier's page, never against the row above it.
Block 8

Quarterly trend

Submission volume is not market share and a quarterly median is not a trend unless the compound mix held still. Both caveats apply to every row below.

Median purity by quarter

Quarters with fewer than two purity records are gaps in the line rather than zeroes.

Coverage growth

Records added per quarter. Growth here is index coverage, not supplier volume.

QuarterBatchesReportsMedian purityRangeFlagged
2024-Q11899.1698.69–99.932
2024-Q22799.1398.63–99.710
2024-Q31799.3899.26–99.840
2024-Q441798.6397.75–99.837
2025-Q11499.8599.25–99.930
2025-Q253499.4298.62–99.935
2025-Q332599.0698.52–99.656
2025-Q473499.6997.92–99.939
2026-Q163999.5699.07–99.9314
2026-Q254499.0298.01–99.9215
2026-Q331199.8898.98–99.934

Full quarterly timeline, batch by batch →

Block 9

Which laboratory produced these numbers

Laboratories disagree with each other by a measured amount. A supplier tested mostly by one laboratory carries that laboratory's offset in its aggregate, and the adjusted column removes it.

LaboratoryReportsMedian purityLab bias (pp)Bias-adjusted
Janoshik11099.38+0.0099.38
PeptideMeter4399.33-0.0599.38
Medutest3399.35+0.0899.27
VendorInvestigate1699.12-0.1199.23
Nordanalyt1999.46+0.0299.44
Kestrel999.71+0.2499.47

Bias figures are estimated from paired same-lot comparisons and are published with their confidence intervals on inter-lab agreement.

Block 10

What this data does and does not show

Block 11

On-the-record reviews 26

Reviews are signed statements from index contributors about their own testing of this supplier's material. They are opinions attached to evidence, and they are not used in any statistic on this page.

96.0/ 1001,015 ratings across the index network
tu.adeyemi99/100

Packing: the caps crimped evenly, none of them proud of the shoulder.

an.petrov98/100

Published stock status matched availability. Same-day dispatch. Peptide content 99.5%.

p.brandt96/100

Retention time assigned to the principal peak, printed. VendorInvestigate report held on file, figures match published. Subsequent orders placed with the same supplier.

e.zamora95/100

Line quoted that three comparable suppliers declined to quote. Material returned within specification. Tracking record corresponded to consignment position at every hop. Record covers the lots named. Not generalised.

k.nilsen98/100

Lot JEEP-26-411 submitted to PeptideMeter. Declared 97.5%, reported 97.6%. Delta inside method repeatability. n=1, declared as n=1.

ma.ilunga97/100

Orthogonal identity present: mass spectrometry alongside the chromatographic determination. Desiccant enclosed within the secondary container.

br.osei95/100

Single lot identifier across the whole consignment. Intra-consignment comparison valid. Gradient and column chemistry stated. Documentation practice, not a single purity figure, is the substance here.

so.moreau99/100

Fill uniformity: 8 units weighed against declared fill, all within 2%.

h.barros97/100

Transit 2 days from stock held in the United States against a quoted 2. Customs documentation correct at first presentation. Technical response inside four hours, working day. Independent verification of individual lots still required.

a.moreau96/100

Labelling printed, lot and date legible on every unit examined. Regional stock held for the lines concerned.

f.steiner98/100

Blind submission of DSIP 5 mg to VendorInvestigate, origin withheld. 97.3% against 97.0% declared. Figures as reported by the named service. Not reproduced by the index.

j.bergstrom99/100

Storage condition for the stability statement stated on the certificate. Desiccant enclosed within the secondary container.

ja.teixeira96/100

Residual-solvent screen included unrequested. Record covers the lots named. Not generalised.

i.vukovic97/100

Declared figure not adjusted upward between certificate and commercial documentation. Peptide content 98.6%.

s.marchetti100/100

Dispatch on the quoted day. Technical response inside four hours, working day.

ru.sobczak100/100

Tracking number live from despatch and accurate to the hour at every scan. All other particulars in order.

n.yildiz95/100

Batch record supplied in full on request, attached rather than summarised. No further comment.

c.okonkwo96/100

Reconstitution of GHK-Cu 50 mg: clear on contact, no haze, no particulate. Desiccant enclosed within the secondary container.

s.bhattacharya96/100

Consistency: 9 lots, purity band under 1.0 points wide. Signature and release date present. Evidence base adequate for a rating on this criterion.

h.erdogan97/100

Purity by RP-HPLC, wavelength stated, stability-indicating method named. Determination is reproducible from the certificate alone. No excipient. Cake intact. Not medical advice.

k.molnar95/100

Two lots ordered deliberately for comparison. Reported purities 0.1 points apart. Technical response inside four hours, working day.

g.nascimento100/100

Labels printed square and legible on every unit, lot code matching the paperwork on each. Regional stock held for the lines concerned.

r.adeyemi98/100

Supplementary certificate for a lot released 9 months earlier retrieved from supplier records on request. Nothing unsecured in the consignment. Further submissions on later lots would improve coverage.

ne.demir97/100

Direct-supply material 99.2%. Intermediary vial, same nominal description, 98.9%.

ro.kimani99/100

3 orders, 18 months. No substitution, no reformulation, no post-payment unavailability. Figures as reported by the named service. Not reproduced by the index.

ra.restrepo98/100

Custom synthesis delivered 2 days inside the quoted schedule at the specified purity. No excipient. Cake intact. Documentation practice, not a single purity figure, is the substance here.

Block 12

Most recent records

The 25 most recently submitted JEEP records. All 230 are listed on the full record listing.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042177HexarelinJEEP-2608-Y9547Janoshik2026-Q399.903.42Buyer-sourced0PASS
AX-2026-042162SemaglutideJEEP-2607-X9091Janoshik2026-Q398.983.46Laboratory-retained1MARGINAL
AX-2026-042127TB-500JEEP-2602-V8614Medutest2026-Q399.683.55Buyer-sourced1FAIL
AX-2026-042123TB-500JEEP-2602-V8614PeptideMeter2026-Q399.933.80Buyer-sourced0PASS
AX-2026-042124TB-500JEEP-2602-V8614PeptideMeter2026-Q399.913.37104.9Buyer-sourced0PASS
AX-2026-042178HexarelinJEEP-2608-Y9547VendorInvestigate2026-Q399.684.03Buyer-sourced0PASS
AX-2026-042163SemaglutideJEEP-2607-X9091Nordanalyt2026-Q399.464.52Buyer-sourced1MARGINAL
AX-2026-042122TB-500JEEP-2602-V8614PeptideMeter2026-Q399.603.5897.0Buyer-sourced0PASS
AX-2026-042126TB-500JEEP-2602-V8614Janoshik2026-Q399.932.82Buyer-sourced0PASS
AX-2026-042128TB-500JEEP-2602-V8614Kestrel2026-Q399.933.4394.3Buyer-sourced0PASS
AX-2026-042125TB-500JEEP-2602-V8614VendorInvestigate2026-Q399.883.72Buyer-sourced1MARGINAL
AX-2026-042139PT-141 (Bremelanotide)JEEP-2601-K8195VendorInvestigate2026-Q298.324.2999.4Buyer-sourced1FAIL
AX-2026-042120TirzepatideJEEP-2602-J7978Nordanalyt2026-Q298.864.68Buyer-sourced0PASS
AX-2026-042168Melanotan IIJEEP-2604-R9103Nordanalyt2026-Q299.405.71Buyer-sourced0PASS
AX-2026-042164Melanotan IIJEEP-2604-R9103Janoshik2026-Q299.545.23Buyer-sourced1MARGINAL
AX-2026-042121TirzepatideJEEP-2602-J7978Nordanalyt2026-Q298.564.41Buyer-sourced0PASS
AX-2026-042107TirzepatideJEEP-2602-J7978Nordanalyt2026-Q299.404.57Buyer-sourced0PASS
AX-2026-042132PT-141 (Bremelanotide)JEEP-2601-K8195Medutest2026-Q298.654.3096.6Buyer-sourced1MARGINAL
AX-2026-042114TirzepatideJEEP-2602-J7978Nordanalyt2026-Q298.834.17102.3Buyer-sourced0PASS
AX-2026-042117TirzepatideJEEP-2602-J7978Janoshik2026-Q298.925.3299.8Buyer-sourced0PASS
AX-2026-042135PT-141 (Bremelanotide)JEEP-2601-K8195Janoshik2026-Q298.444.64Buyer-sourced1FAIL
AX-2026-042133PT-141 (Bremelanotide)JEEP-2601-K8195Medutest2026-Q298.954.23Buyer-sourced1MARGINAL
AX-2026-042148CagrilintideJEEP-2603-E9024Janoshik2026-Q298.666.33Buyer-sourced0PASS
AX-2026-042140PT-141 (Bremelanotide)JEEP-2601-K8195Janoshik2026-Q298.283.89Buyer-sourced1FAIL
AX-2026-042112TirzepatideJEEP-2602-J7978Janoshik2026-Q299.154.37Buyer-sourced0PASS
Block 13

Contributor annotations on JEEP records 484

Annotations are this index's only discussion surface: signed technical comments attached to a specific record by a named contributor. They are not moderated for agreement with the index's own arithmetic. The most recent on JEEP material are below, each linked to the record it sits on.

On a low-resolution pair the baseline between the peaks never reaches baseline, so any integration is an extrapolation. Stating which extrapolation was used is worth more than any threshold.
Valley height relative to the smaller peak is the practical criterion an operator uses, and it is not on the report. Resolution is a proxy for it and an imperfect one on asymmetric pairs.
Anyone comparing this purity figure against a result from a longer method should expect a difference of a few tenths in a predictable direction. The inter-lab page quantifies it per laboratory.
Reported as signed ppm, which is the right convention: direction carries information about calibration that a modulus discards.
Independently purchased, at the submitter's own cost, forwarded without the supplier's involvement. That is the definition and this record meets it.
A unit-resolution instrument confirms that a species of approximately the right mass is present. It never confirms a species of exactly the right mass, and the index's status vocabulary distinguishes the two deliberately.
An unrecognised sodium adduct shifts an apparent monoisotopic mass by about 22 Da, which at this molecular weight is far more than -15.2 ppm. Rule that out first; it is the cheapest check available.

Every annotation the index holds on JEEP material sits on its own record; the full set is reachable from the record listing and from each contributor's page. To read them against what JEEP itself publishes, open jeepbio.com → alongside.

Block 14

Where to buy JEEP

Guangzhou JEEP Biotechnology Co., Ltd. sells direct from jeepbio.com. Everything on this page describes lots the index has already seen; the certificate that matters is the one that arrives with the vial you order, and the lot code on it should match the vial. Ask for the lot-specific document rather than the batch-level summary, and ask for the integration report if you intend to reconcile the figure yourself.

Go to the JEEP store at jeepbio.com →

Marked nofollow and sponsored. The index is paid nothing for it, takes no commission, and a link is not an assessment. Research compounds. Not medical advice. Nothing on this site is a safety assessment and nothing on it is approved for human use.