AssayIndex

AX-2024-004653

Retatrutide · 15 mg declared · Tianjin Finder Chemical Co., Ltd. · lot TFC-2309-H2397

PASSIDENTITY CONSISTENT
Report ID
AX-2024-004653
Compound
Retatrutide
Compound class
Incretin analogues and co-agonists
Supplier
TFC — Tianjin Finder Chemical Co., Ltd.
Batch / lot
TFC-2309-H2397
Declared label claim
15mg
Laboratory
Medutest
Assay date
14 Jan 2024
Submitted
02 Feb 2024
Quarter
2024-Q1
Submitter
Contributor #F-2358
Sample provenance
Laboratory-retained
Section 1

Results

Measured against the index acceptance specification for the incretin analogues and co-agonists class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 25 min gradient, 214 nm98.29% area≥ 96.5PASS
Total impuritiesRP-HPLC, sum of reported peaks1.71% area≤ 3.5PASS
Largest single impurityRP-HPLC — [D-Aib2]-diastereomer0.77% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula4728.4871DaNOT TESTED
Identity — observed monoisotopic massLC-MS, unit resolution (single quadrupole)4728.5301DaNOT TESTED
Mass accuracyobserved vs theoretical+9.1ppm± 15PASS
Peptide contentnot ordered on this submissionnot determinedrequired to check label claimNOT TESTED
Water contentKarl Fischer, coulometric, duplicate3.41%≤ 8.0PASS
Counter-ion (TFA)anion-exchange ion chromatography7.64%≤ 12.0PASS
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.82%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite to pale-yellow cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration3.702.5 – 8.0PASS
Retention time (observed)RP-HPLC, 25 min gradient17.49min17.53 ± 0.50 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.120.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²72,594≥ 20,000PASS
Resolution to nearest impurityvs [D-Aib2]-diastereomer0.69no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

01654330849626616 Retatrutide17.49 min · 98.29 % 17.3120.92 same trace · ×50 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 0481216202428 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 25 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 72,594, and skew follows the reported asymmetry factor of 1.12. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.77 % impurity against a 98.29 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1Retatrutide — main peak17.494,777,19998.29
2[D-Aib2]-diastereomer17.3137,4240.770.000
3truncated (5-39)15.8924,3020.50-428.201
4des-Aib20 analogue17.1210,6930.22-85.053
5retatrutide dimer20.925,8320.12+4728.487
6oxidised Trp (+16 Da)16.942,9160.06+15.995
7C18 diacid regioisomer17.971,9440.040.000
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 4728.4871 Da, computed from C221H342N46O68. All ppm figures on this site are against monoisotopic values — see why that matters.

0255075100550750950115013501550 [M+5H]5+946.71[M+4H]4+1183.14[M+6H]6+789.10 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, unit-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 4728.5301 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
7+676.5054676.51160.00628.0
6+789.0885789.09560.007156.6
5+946.7047946.71330.0086100.0
4+1183.12911183.13980.010757.1
3+1577.16961577.18400.01448.4
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.9098.29divergence +1.27 pp vs batch median
Total impurities (% area)0.101.71
Largest single impurity (% area)0.070.77
Water (%)2.43.41
Counter-ion (%)2.67.64
Peptide content (%w/w)94.4not determined
Endotoxin (EU/mg)not statednot determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Laboratory-retained
Evidentiary weight
Provenance documented, selection uncontrolled.
Chain of custody
Laboratory retained sample (−20 °C, 27 d since original receipt) → re-assay.
Assay date
14 Jan 2024
Submitted to the index
02 Feb 2024
Laboratory
Medutest, Ljubljana, Slovenia
Method basis
25 min gradient · unit-resolution MS
Verification status
IDENTITY CONSISTENT
Section 6

Annotations 2

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

baseline_noise
On a low-resolution pair the baseline between the peaks never reaches baseline, so any integration is an extrapolation. Stating which extrapolation was used is worth more than any threshold.
sec_monomer
Where the close neighbour is an aggregate rather than a related substance, size exclusion separates them trivially and reverse phase never will.
Section 7

Related records

Same batch — lot TFC-2309-H2397 n=17

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2024-004645TFC-2309-H2397Janoshik2024-Q198.533.7090.7Buyer-sourced0PASS
AX-2024-004646TFC-2309-H2397Nordanalyt2024-Q198.674.32102.6Buyer-sourced2FAIL
AX-2024-004647TFC-2309-H2397Nordanalyt2024-Q198.504.42Supplier-supplied0PASS
AX-2024-004648TFC-2309-H2397PeptideMeter2024-Q198.664.06104.9Buyer-sourced0PASS
AX-2024-004649TFC-2309-H2397PeptideMeter2024-Q198.793.64Buyer-sourced0PASS
AX-2024-004650TFC-2309-H2397Medutest2024-Q198.743.93100.4Buyer-sourced1MARGINAL
AX-2024-004651TFC-2309-H2397Janoshik2024-Q198.863.9099.4Buyer-sourced0PASS
AX-2024-004652TFC-2309-H2397PeptideMeter2024-Q198.634.14Buyer-sourced0PASS
AX-2024-004654TFC-2309-H2397Janoshik2024-Q198.484.64100.7Buyer-sourced0PASS
AX-2024-004655TFC-2309-H2397VendorInvestigate2024-Q198.433.6493.7Buyer-sourced0PASS
AX-2024-004656TFC-2309-H2397Janoshik2024-Q198.494.83Buyer-sourced1FAIL
AX-2024-004657TFC-2309-H2397PeptideMeter2024-Q198.674.27Buyer-sourced0PASS
AX-2024-004658TFC-2309-H2397PeptideMeter2024-Q198.704.31105.7Buyer-sourced0PASS
AX-2024-004659TFC-2309-H2397Medutest2024-Q198.363.87Buyer-sourced0PASS
AX-2024-004660TFC-2309-H2397Medutest2024-Q198.763.96105.4Buyer-sourced0PASS
AX-2024-004661TFC-2309-H2397VendorInvestigate2024-Q198.504.3496.3Buyer-sourced0PASS
Other recent Retatrutide records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042437HomopeptideHOMO-2605-V4718Nordanalyt2026-Q398.683.67102.8Buyer-sourced0PASS
AX-2026-043095KPKP-2607-H5774Janoshik2026-Q395.815.48105.2Buyer-sourced0FAIL
AX-2026-042282TFCTFC-2608-J1156Janoshik2026-Q398.544.27Buyer-sourced0PASS
AX-2026-043094KPKP-2607-H5774PeptideMeter2026-Q396.326.40Buyer-sourced0FAIL
AX-2026-042441HomopeptideHOMO-2605-V4718Medutest2026-Q398.934.22Buyer-sourced0PASS
AX-2026-041427QYBQYB-2604-B4920PeptideMeter2026-Q397.932.45101.7Buyer-sourced0PASS
AX-2026-041786ASYASY-{CAT}-2288VendorInvestigate2026-Q398.786.59Buyer-sourced0PASS
AX-2026-041428QYBQYB-2604-B4920Janoshik2026-Q398.353.20Laboratory-retained0PASS
Other recent TFC records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042265Humanin (HNG)TFC-2605-U1300PeptideMeter2026-Q399.526.31Buyer-sourced0PASS
AX-2026-042222SS-31 (Elamipretide)TFC-2607-R9099VendorInvestigate2026-Q399.465.41102.6Buyer-sourced0PASS
AX-2026-042236Humanin (HNG)TFC-2608-S9940Nordanalyt2026-Q398.641.80Buyer-sourced0PASS
AX-2026-042282RetatrutideTFC-2608-J1156Janoshik2026-Q398.544.27Buyer-sourced0PASS
AX-2026-042226SS-31 (Elamipretide)TFC-2607-R9099Janoshik2026-Q399.625.47Buyer-sourced0PASS
AX-2026-042217SemaglutideTFC-2604-X9037PeptideMeter2026-Q398.954.6196.9Buyer-sourced0PASS
AX-2026-042339SermorelinTFC-2605-Y2176Kestrel2026-Q399.934.14Supplier-supplied1FAIL
AX-2026-042214SemaglutideTFC-2604-X9037Kestrel2026-Q399.874.66103.1Laboratory-retained0PASS