AssayIndex

AX-2026-042568

Ipamorelin · 2 mg declared · Hubei Jianxiang Bioscience Co., Ltd. · lot HJ-2604-T6645

FAILIDENTITY CONSISTENT
Report ID
AX-2026-042568
Compound
Ipamorelin
Compound class
Growth-hormone axis peptides
Supplier
HJ — Hubei Jianxiang Bioscience Co., Ltd.
Batch / lot
HJ-2604-T6645
Declared label claim
2mg
Laboratory
Janoshik Analytical
Assay date
25 May 2026
Submitted
12 Jun 2026
Quarter
2026-Q2
Submitter
a.bergstrom
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the growth-hormone axis peptides class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 30 min gradient, 214 nm98.99% area≥ 99.0FAIL
Total impuritiesRP-HPLC, sum of reported peaks1.01% area≤ 1.0FAIL
Largest single impurityRP-HPLC — [D-Trp]-epimer0.47% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula711.3856DaNOT TESTED
Identity — observed monoisotopic massLC-MS, high resolution (ESI-TOF/QTOF)711.3821DaNOT TESTED
Mass accuracyobserved vs theoretical-4.9ppm± 15PASS
Peptide contentnot ordered on this submissionnot determinedrequired to check label claimNOT TESTED
Water contentKarl Fischer, coulometric, duplicate5.14%≤ 9.0PASS
Counter-ion (acetate)anion-exchange ion chromatography4.85%≤ 12.0PASS
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.64%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration5.212.5 – 8.0PASS
Retention time (observed)RP-HPLC, 30 min gradient8.38min8.24 ± 0.25 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.460.970.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²59,921≥ 20,000PASS
Resolution to nearest impurityvs [D-Trp]-epimer0.85no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

0339867961019513593 Ipamorelin8.38 min · 98.99 % 8.26 same trace · ×100 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 05101520253035 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 30 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 59,921, and skew follows the reported asymmetry factor of 0.97. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.47 % impurity against a 98.99 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1Ipamorelin — main peak8.384,811,22198.99
2[D-Trp]-epimer8.2622,8430.470.000
3oxidised Trp (+16 Da)8.0414,0950.29+15.995
4Aib-deletion sequence (−85 Da)8.105,3460.11-85.053
5C-terminal free acid (+1 Da)8.563,4020.07+0.984
6des-Lys (−128 Da)8.163,4020.07-128.095
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 711.3856 Da, computed from C38H49N9O5. All ppm figures on this site are against monoisotopic values — see why that matters.

0255075100300375450525600675750 [M+1H]1+712.39[M+2H]2+356.70 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, high-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 711.3821 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
2+356.7001356.6983-0.001853.4
1+712.3929712.3894-0.0035100.0
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.3198.99divergence +0.62 pp vs batch median
Total impurities (% area)0.691.01
Largest single impurity (% area)0.300.47
Water (%)3.55.14
Counter-ion (%)not stated4.85
Peptide content (%w/w)not statednot determined
Endotoxin (EU/mg)8.47not determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → submitter (−20 °C, 14 d) → laboratory (courier, dry ice, 8 d) → assay.
Assay date
25 May 2026
Submitted to the index
12 Jun 2026
Laboratory
Janoshik Analytical, Ostrava, Czechia
Method basis
30 min gradient · high-resolution MS
Verification status
IDENTITY CONSISTENT
Section 6

Annotations 3

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

mass_defect
Identity confirmed and purity at 98.99 %. The two answer different questions — what it is, and how much else is in it — and a record carrying both is the version worth citing.
ms_confirm
An orthogonal identity method on the same lot would make this the strongest class of record the index holds. Mass plus retention is already better than most.
coa_reader
The certificate that arrives with a retail order is the certificate an ordinary buyer gets. Assessing it is assessing the real documentation practice rather than the sample-request one.
Section 7

Related records

Same batch — lot HJ-2604-T6645 n=6

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042566HJ-2604-T6645Janoshik2026-Q298.594.9889.6Buyer-sourced2FAIL
AX-2026-042567HJ-2604-T6645Janoshik2026-Q298.505.48Buyer-sourced1FAIL
AX-2026-042569HJ-2604-T6645Medutest2026-Q298.795.8391.5Buyer-sourced0FAIL
AX-2026-042570HJ-2604-T6645Kestrel2026-Q298.855.01103.2Supplier-supplied1FAIL
AX-2026-042571HJ-2604-T6645Janoshik2026-Q298.415.34104.9Buyer-sourced0FAIL
Other recent Ipamorelin records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041377QYBQYB-2605-H3558Nordanalyt2026-Q399.934.35Buyer-sourced0PASS
AX-2026-041913SinoPepSNP-2606-L4478PeptideMeter2026-Q398.885.28Buyer-sourced0FAIL
AX-2026-041914SinoPepSNP-2606-L4478Janoshik2026-Q399.145.49Buyer-sourced0PASS
AX-2026-041909SinoPepSNP-2606-L4478PeptideMeter2026-Q399.005.4889.5Buyer-sourced1MARGINAL
AX-2026-041895SinoPepSNP-2602-B3833Janoshik2026-Q399.934.72105.9Buyer-sourced1MARGINAL
AX-2026-041898SinoPepSNP-2602-B3833Nordanalyt2026-Q399.934.5496.0Buyer-sourced1MARGINAL
AX-2026-041899SinoPepSNP-2602-B3833PeptideMeter2026-Q399.934.9690.1Buyer-sourced1MARGINAL
AX-2026-041891SinoPepSNP-2602-B3833Janoshik2026-Q399.935.11Buyer-sourced1MARGINAL
Other recent HJ records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042595SemaglutideHJ-2608-C7002Janoshik2026-Q399.503.55Buyer-sourced1MARGINAL
AX-2026-042598SemaglutideHJ-2608-C7002Janoshik2026-Q399.593.84Buyer-sourced0PASS
AX-2026-042605SemaglutideHJ-2608-C7002Janoshik2026-Q399.033.37107.3Buyer-sourced0PASS
AX-2026-042602SemaglutideHJ-2608-C7002Nordanalyt2026-Q399.213.5092.0Buyer-sourced0PASS
AX-2026-042603SemaglutideHJ-2608-C7002Janoshik2026-Q399.163.42105.9Buyer-sourced0PASS
AX-2026-042528GHRP-6HJ-2603-R5329VendorInvestigate2026-Q398.691.8795.8Buyer-sourced0FAIL
AX-2026-042526GHRP-6HJ-2603-R5329Medutest2026-Q399.373.06Laboratory-retained0PASS
AX-2026-042527GHRP-6HJ-2603-R5329VendorInvestigate2026-Q399.212.7793.2Buyer-sourced0PASS