AssayIndex

AX-2024-005051

Thymosin α1 · 1.6 mg declared · Shanghai Sigma-Audley New Material Technology Co., Ltd. · lot SSA-2407-L6364

MARGINALVERIFIED
Report ID
AX-2024-005051
Compound
Thymosin α1
Compound class
Tissue-repair and immunomodulatory peptides
Supplier
SSA — Shanghai Sigma-Audley New Material Technology Co., Ltd.
Batch / lot
SSA-2407-L6364
Declared label claim
2mg
Laboratory
PeptideMeter
Assay date
22 Jul 2024
Submitted
04 Aug 2024
Quarter
2024-Q3
Submitter
v.norgaard
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the tissue-repair and immunomodulatory peptides class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 28 min gradient, 214 nm98.29% area≥ 97.5PASS
Total impuritiesRP-HPLC, sum of reported peaks1.71% area≤ 2.5PASS
Largest single impurityRP-HPLC — des-acetyl Tα1 (−42 Da)1.20% area≤ 1.00FAIL
Identity — theoretical monoisotopic masscalculated from molecular formula3106.5493DaNOT TESTED
Identity — observed monoisotopic massLC-MS, high resolution (ESI-TOF/QTOF)3106.5450DaNOT TESTED
Mass accuracyobserved vs theoretical-1.4ppm± 15PASS
Total peptide contentby difference from the gravimetric mass balance91.99%w/wNOT TESTED
Target-compound contenttotal peptide content × purity90.42%w/wNOT TESTED
Gross fill (as weighed)five-place balance, under nitrogen1.75mg1.6 mg declaredNOT TESTED
Recovered target peptidegross fill × target content1.582mg1.6 mg claimNOT TESTED
Recovery against label claimrecovered ÷ claim98.9%90.0 – 110.0PASS
Water contentKarl Fischer, coulometric, duplicate1.46%≤ 10.0PASS
Counter-ion (acetate)anion-exchange ion chromatography5.58%≤ 12.0PASS
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.97%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration4.362.5 – 8.0PASS
Retention time (observed)RP-HPLC, 28 min gradient12.04min11.94 ± 0.30 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.050.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²48,152≥ 20,000PASS
Resolution to nearest impurityvs deamidated Asn (+1 Da)1.41no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

02023404660698092 Thymosin α112.04 min · 98.29 % 11.41 same trace · ×50 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 051015202530 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 28 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 48,152, and skew follows the reported asymmetry factor of 1.05. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 1.20 % impurity against a 98.29 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1Thymosin α1 — main peak12.044,777,19998.29
2des-acetyl Tα1 (−42 Da)11.4158,3241.20-42.011
3deamidated Asn (+1 Da)11.7217,4970.36+0.984
4aspartimide (−18 Da)12.434,3740.09-18.011
5truncated (1-24)10.882,9160.06-487.229
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 3106.5493 Da, computed from C129H215N33O55. All ppm figures on this site are against monoisotopic values — see why that matters.

02550751005007009001100130015001700 [M+3H]3+1036.52[M+4H]4+777.64[M+2H]2+1554.28 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, high-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 3106.5450 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
5+622.3171622.3163-0.00088.7
4+777.6446777.6435-0.001159.0
3+1036.52371036.5223-0.0014100.0
2+1554.28191554.2798-0.002155.6
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

ComponentDetermination%w/w of cake
WaterKarl Fischer1.46
Counter-ion (acetate)ion chromatography5.58
Residual solvent + inorganic residueestimated0.97
Total peptide contentby difference91.99
Total100.00 CLOSES

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)98.598.29divergence +0.11 pp vs batch median
Total impurities (% area)1.501.71
Largest single impurity (% area)not stated1.20
Water (%)not stated1.46
Counter-ion (%)not stated5.58
Peptide content (%w/w)91.791.99
Endotoxin (EU/mg)not statednot determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → submitter (−20 °C, 19 d) → laboratory (courier, dry ice, 3 d) → assay.
Assay date
22 Jul 2024
Submitted to the index
04 Aug 2024
Laboratory
PeptideMeter, Tallinn, Estonia
Method basis
28 min gradient · high-resolution MS
Verification status
VERIFIED
Section 6

Annotations 2

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

buyer_sourced
Anyone can generate one of these. That is the argument the index makes on its submission page and it is the reason the dataset grows without any supplier's cooperation.
sec_monomer
Where the close neighbour is an aggregate rather than a related substance, size exclusion separates them trivially and reverse phase never will.
Section 7

Related records

Same batch — lot SSA-2407-L6364 n=6

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2024-005049SSA-2407-L6364Janoshik2024-Q398.701.48104.2Buyer-sourced1MARGINAL
AX-2024-005050SSA-2407-L6364Janoshik2024-Q398.481.8191.9Buyer-sourced1MARGINAL
AX-2024-005052SSA-2407-L6364PeptideMeter2024-Q398.161.28Buyer-sourced1MARGINAL
AX-2024-005053SSA-2407-L6364Janoshik2024-Q398.851.52Buyer-sourced1MARGINAL
AX-2024-005054SSA-2407-L6364Medutest2024-Q398.221.13Buyer-sourced1MARGINAL
Other recent Thymosin α1 records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041996AMBAMB-2511-B5683VendorInvestigate2026-Q299.314.2091.2Buyer-sourced0PASS
AX-2026-041995AMBAMB-2511-B5683PeptideMeter2026-Q298.864.00104.5Buyer-sourced0PASS
AX-2026-041998AMBAMB-2511-B5683Nordanalyt2026-Q299.083.83Buyer-sourced0PASS
AX-2026-043232SGNSGN-2512-Y9621Janoshik2026-Q299.426.8889.1Buyer-sourced1MARGINAL
AX-2026-041999AMBAMB-2511-B5683Medutest2026-Q299.933.95102.2Supplier-supplied1MARGINAL
AX-2026-041997AMBAMB-2511-B5683PeptideMeter2026-Q299.114.26104.3Buyer-sourced0PASS
AX-2026-041442QYBQYB-2511-V5408Kestrel2026-Q199.822.3596.1Buyer-sourced0PASS
AX-2026-041438QYBQYB-2511-V5408Janoshik2026-Q199.802.70105.2Buyer-sourced0PASS
Other recent SSA records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043135BPC-157SSA-2601-N6863Nordanalyt2026-Q298.164.6692.8Buyer-sourced1MARGINAL
AX-2026-043160GHK-CuSSA-2604-V7731Janoshik2026-Q298.014.0291.8Buyer-sourced0PASS
AX-2026-043157GHK-CuSSA-2604-V7731Medutest2026-Q299.195.14Supplier-supplied0PASS
AX-2026-043141BPC-157SSA-2601-N6863Janoshik2026-Q298.064.0694.6Buyer-sourced1MARGINAL
AX-2026-043154GHK-CuSSA-2604-V7731PeptideMeter2026-Q297.824.82101.6Buyer-sourced0PASS
AX-2026-043137BPC-157SSA-2601-N6863PeptideMeter2026-Q298.174.14Buyer-sourced1MARGINAL
AX-2026-043162GHK-CuSSA-2604-V7731Janoshik2026-Q298.504.36Supplier-supplied0PASS
AX-2026-043134BPC-157SSA-2601-N6863Medutest2026-Q297.894.01Buyer-sourced1FAIL