AssayIndex

AX-2026-043141

BPC-157 · 2 mg declared · Shanghai Sigma-Audley New Material Technology Co., Ltd. · lot SSA-2601-N6863

MARGINALPURITY ONLY
Report ID
AX-2026-043141
Compound
BPC-157
Compound class
Tissue-repair and immunomodulatory peptides
Supplier
SSA — Shanghai Sigma-Audley New Material Technology Co., Ltd.
Batch / lot
SSA-2601-N6863
Declared label claim
2mg
Laboratory
Janoshik Analytical
Assay date
21 Jun 2026
Submitted
02 Jul 2026
Quarter
2026-Q2
Submitter
Contributor #Y-5136
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the tissue-repair and immunomodulatory peptides class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 30 min gradient, 214 nm98.06% area≥ 98.0PASS
Total impuritiesRP-HPLC, sum of reported peaks1.94% area≤ 2.0PASS
Largest single impurityRP-HPLC — pyroglutamate cyclisation (−17 Da)1.19% area≤ 1.00FAIL
Identitynot ordered on this submissionnot determinedrequired for VERIFIED statusNOT TESTED
Total peptide contentby difference from the gravimetric mass balance88.93%w/wNOT TESTED
Target-compound contenttotal peptide content × purity87.20%w/wNOT TESTED
Gross fill (as weighed)five-place balance, under nitrogen2.17mg2 mg declaredNOT TESTED
Recovered target peptidegross fill × target content1.892mg2 mg claimNOT TESTED
Recovery against label claimrecovered ÷ claim94.6%90.0 – 110.0PASS
Water contentKarl Fischer, coulometric, duplicate4.06%≤ 10.0PASS
Counter-ion (acetate)anion-exchange ion chromatography6.54%≤ 12.0PASS
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.47%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear after 90 s gentle swirling, no particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration5.752.5 – 8.0PASS
Retention time (observed)RP-HPLC, 30 min gradient9.77min9.62 ± 0.25 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.460.860.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²56,735≥ 20,000PASS
Resolution to nearest impurityvs [D-Val]-diastereomer0.83no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

029135826873911652 BPC-1579.77 min · 98.06 % 10.08 same trace · ×50 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 05101520253035 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 30 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 56,735, and skew follows the reported asymmetry factor of 0.86. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 1.19 % impurity against a 98.06 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1BPC-157 — main peak9.774,766,02098.06
2pyroglutamate cyclisation (−17 Da)10.0857,8381.19-17.027
3des-Gly truncate (−57 Da)9.4323,8160.49-57.021
4acetylated N-terminus (+42 Da)10.256,8040.14+42.011
5[D-Val]-diastereomer9.632,4300.050.000
6BPC-157 arginine-salt artefact9.221,9440.040.000
7truncated (1-12)8.811,4580.03-285.132
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

ComponentDetermination%w/w of cake
WaterKarl Fischer4.06
Counter-ion (acetate)ion chromatography6.54
Residual solvent + inorganic residueestimated0.47
Total peptide contentby difference88.93
Total100.00 CLOSES

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)97.598.06divergence -0.53 pp vs batch median
Total impurities (% area)not stated1.94
Largest single impurity (% area)not stated1.19
Water (%)3.64.06
Counter-ion (%)8.36.54
Peptide content (%w/w)87.588.93
Endotoxin (EU/mg)0.47not determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Domestic warehouse despatch → submitter (2–8 °C, 2 d) → laboratory (courier, cold pack, 2 d) → assay.
Assay date
21 Jun 2026
Submitted to the index
02 Jul 2026
Laboratory
Janoshik Analytical, Ostrava, Czechia
Method basis
30 min gradient · high-resolution MS
Verification status
PURITY ONLY
Section 6

Annotations 2

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

coa_gap
Rounding convention is the least of what a certificate carries. Lot code, method, wavelength and release date are the fields that let a reader reconstruct the figure, and the index scores those separately on the documentation rubric.
valley_drop
Valley height relative to the smaller peak is the practical criterion an operator uses, and it is not on the report. Resolution is a proxy for it and an imperfect one on asymmetric pairs.
Section 7

Related records

Same batch — lot SSA-2601-N6863 n=15

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043130SSA-2601-N6863Janoshik2026-Q297.574.69100.4Buyer-sourced1FAIL
AX-2026-043131SSA-2601-N6863Janoshik2026-Q297.754.43100.0Buyer-sourced1FAIL
AX-2026-043132SSA-2601-N6863Janoshik2026-Q298.034.34Buyer-sourced1MARGINAL
AX-2026-043133SSA-2601-N6863Janoshik2026-Q298.374.34106.6Supplier-supplied1MARGINAL
AX-2026-043134SSA-2601-N6863Medutest2026-Q297.894.01Buyer-sourced1FAIL
AX-2026-043135SSA-2601-N6863Nordanalyt2026-Q298.164.6692.8Buyer-sourced1MARGINAL
AX-2026-043136SSA-2601-N6863Janoshik2026-Q298.524.0292.4Buyer-sourced1MARGINAL
AX-2026-043137SSA-2601-N6863PeptideMeter2026-Q298.174.14Buyer-sourced1MARGINAL
AX-2026-043138SSA-2601-N6863VendorInvestigate2026-Q297.994.2090.1Buyer-sourced1FAIL
AX-2026-043139SSA-2601-N6863Janoshik2026-Q297.784.6799.8Buyer-sourced1FAIL
AX-2026-043140SSA-2601-N6863PeptideMeter2026-Q297.864.85105.9Buyer-sourced1FAIL
AX-2026-043142SSA-2601-N6863Medutest2026-Q298.194.8395.2Buyer-sourced1MARGINAL
AX-2026-043143SSA-2601-N6863Janoshik2026-Q297.915.02Buyer-sourced1FAIL
AX-2026-043144SSA-2601-N6863Janoshik2026-Q298.084.74Buyer-sourced1MARGINAL
Other recent BPC-157 records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043319CPCCPC-2602-W1610Medutest2026-Q398.822.88103.5Buyer-sourced2MARGINAL
AX-2026-041766TFSTFS-{CAT}-1156Janoshik2026-Q399.546.34Buyer-sourced1MARGINAL
AX-2026-043445BCHBCH-2603-G4350Nordanalyt2026-Q398.424.8793.6Buyer-sourced1MARGINAL
AX-2026-043440BCHBCH-2603-G4350VendorInvestigate2026-Q398.614.11Buyer-sourced1MARGINAL
AX-2026-043442BCHBCH-2603-G4350Janoshik2026-Q398.654.78Buyer-sourced1MARGINAL
AX-2026-043449BCHBCH-2603-G4350Kestrel2026-Q399.744.9291.3Supplier-supplied2MARGINAL
AX-2026-043448BCHBCH-2603-G4350Janoshik2026-Q398.554.69106.9Buyer-sourced1MARGINAL
AX-2026-043318CPCCPC-2602-W1610VendorInvestigate2026-Q398.473.12104.1Buyer-sourced1MARGINAL
Other recent SSA records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043135BPC-157SSA-2601-N6863Nordanalyt2026-Q298.164.6692.8Buyer-sourced1MARGINAL
AX-2026-043160GHK-CuSSA-2604-V7731Janoshik2026-Q298.014.0291.8Buyer-sourced0PASS
AX-2026-043157GHK-CuSSA-2604-V7731Medutest2026-Q299.195.14Supplier-supplied0PASS
AX-2026-043154GHK-CuSSA-2604-V7731PeptideMeter2026-Q297.824.82101.6Buyer-sourced0PASS
AX-2026-043137BPC-157SSA-2601-N6863PeptideMeter2026-Q298.174.14Buyer-sourced1MARGINAL
AX-2026-043162GHK-CuSSA-2604-V7731Janoshik2026-Q298.504.36Supplier-supplied0PASS
AX-2026-043134BPC-157SSA-2601-N6863Medutest2026-Q297.894.01Buyer-sourced1FAIL
AX-2026-043150SemaxSSA-2604-L7739VendorInvestigate2026-Q298.708.9796.7Buyer-sourced1MARGINAL