AssayIndex

AX-2026-043612

CJC-1295 with DAC · 10 mg declared · PolyPeptide Group (Hangzhou) Co., Ltd. · lot PPG-2603-Y7499

PASSPURITY ONLY
Report ID
AX-2026-043612
Compound
CJC-1295 with DAC
Compound class
Growth-hormone axis peptides
Supplier
PPG — PolyPeptide Group (Hangzhou) Co., Ltd.
Batch / lot
PPG-2603-Y7499
Declared label claim
10mg
Laboratory
Medutest
Assay date
15 Feb 2026
Submitted
08 Mar 2026
Quarter
2026-Q1
Submitter
r.yildiz
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the growth-hormone axis peptides class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 25 min gradient, 214 nm99.65% area≥ 97.5PASS
Total impuritiesRP-HPLC, sum of reported peaks0.35% area≤ 2.5PASS
Largest single impurityRP-HPLC — maleimide dimer0.14% area≤ 1.00PASS
Identitynot ordered on this submissionnot determinedrequired for VERIFIED statusNOT TESTED
Total peptide contentby difference from the gravimetric mass balance90.09%w/wNOT TESTED
Target-compound contenttotal peptide content × purity89.77%w/wNOT TESTED
Gross fill (as weighed)five-place balance, under nitrogen10.45mg10 mg declaredNOT TESTED
Recovered target peptidegross fill × target content9.381mg10 mg claimNOT TESTED
Recovery against label claimrecovered ÷ claim93.8%90.0 – 110.0PASS
Water contentKarl Fischer, coulometric, duplicate5.70%≤ 9.0PASS
Counter-ion (acetate)anion-exchange ion chromatography3.72%≤ 12.0PASS
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.49%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite cake, partial shrinkage from vial wallwhite to off-white intact cakeFAIL
Reconstitution clarityreconstituted per submitter procedureClear after 90 s gentle swirling, no particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration4.922.5 – 8.0PASS
Retention time (observed)RP-HPLC, 25 min gradient12.39min12.38 ± 0.35 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.170.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²61,475≥ 20,000PASS
Resolution to nearest impurityvs deamidated (+1 Da)1.06no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

02128425563838510 CJC-1295 with DAC12.39 min · 99.65 % 14.4112.17 same trace · ×200 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 0481216202428 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 25 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 61,475, and skew follows the reported asymmetry factor of 1.17. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.14 % impurity against a 99.65 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1CJC-1295 with DAC — main peak12.394,843,29999.65
2maleimide dimer14.416,8040.14+3644.975
3deamidated (+1 Da)12.175,3460.11+0.984
4hydrolysed maleimide (+18 Da)11.872,4300.05+18.011
5mod-GRF (1-29) (−279 Da)10.922,4300.05-279.235
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

ComponentDetermination%w/w of cake
WaterKarl Fischer5.70
Counter-ion (acetate)ion chromatography3.72
Residual solvent + inorganic residueestimated0.49
Total peptide contentby difference90.09
Total100.00 CLOSES

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.0799.65divergence -0.38 pp vs batch median
Total impurities (% area)0.930.35
Largest single impurity (% area)not stated0.14
Water (%)4.25.70
Counter-ion (%)not stated3.72
Peptide content (%w/w)91.090.09
Endotoxin (EU/mg)not statednot determined
Method stated on certificateNOno method section — the result cannot be reconciled against any other
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → submitter (−20 °C, 23 d) → laboratory (courier, dry ice, 12 d) → assay.
Assay date
15 Feb 2026
Submitted to the index
08 Mar 2026
Laboratory
Medutest, Ljubljana, Slovenia
Method basis
25 min gradient · unit-resolution MS
Verification status
PURITY ONLY
Section 6

Annotations 2

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

baseline_noise
Baseline on this trace is flat enough that the reporting threshold is doing real work rather than hiding peaks in noise. That is a precondition for believing 99.65 % and it is not always met.
coa_reader
The certificate that arrives with a retail order is the certificate an ordinary buyer gets. Assessing it is assessing the real documentation practice rather than the sample-request one.
Section 7

Related records

Same batch — lot PPG-2603-Y7499 n=2

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043613PPG-2603-Y7499PeptideMeter2026-Q199.256.1294.2Supplier-supplied0PASS
Other recent CJC-1295 with DAC records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041681TFSTFS-{CAT}-9675PeptideMeter2026-Q398.823.67Buyer-sourced0PASS
AX-2026-041867SinoPepSNP-2607-C3886Janoshik2026-Q399.245.12Laboratory-retained1FAIL
AX-2026-041682TFSTFS-{CAT}-9675Nordanalyt2026-Q398.943.24Buyer-sourced0PASS
AX-2026-041683TFSTFS-{CAT}-9675Medutest2026-Q398.683.4697.0Buyer-sourced0PASS
AX-2026-043471BCHBCH-2607-H5235Janoshik2026-Q397.465.48Buyer-sourced1FAIL
AX-2026-043477BCHBCH-2607-H5235VendorInvestigate2026-Q397.625.3299.6Buyer-sourced1MARGINAL
AX-2026-043470BCHBCH-2607-H5235Janoshik2026-Q397.766.1199.3Supplier-supplied1MARGINAL
AX-2026-043478BCHBCH-2607-H5235PeptideMeter2026-Q397.635.4290.1Buyer-sourced1MARGINAL
Other recent PPG records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043598TesamorelinPPG-2608-A6835Kestrel2026-Q398.912.56100.3Buyer-sourced1FAIL
AX-2026-043597TesamorelinPPG-2608-A6835Janoshik2026-Q398.541.15Buyer-sourced0PASS
AX-2026-043596TesamorelinPPG-2608-A6835PeptideMeter2026-Q398.741.83105.1Buyer-sourced1MARGINAL
AX-2026-043605RetatrutidePPG-2604-X7060Janoshik2026-Q298.174.2999.7Buyer-sourced0PASS
AX-2026-043601RetatrutidePPG-2604-X7060Janoshik2026-Q298.283.9695.3Buyer-sourced0PASS
AX-2026-043668AOD-9604PPG-2602-W8018PeptideMeter2026-Q299.473.06Buyer-sourced0PASS
AX-2026-043670AOD-9604PPG-2602-W8018PeptideMeter2026-Q299.562.71104.5Buyer-sourced0PASS
AX-2026-043630CJC-1295 (no DAC)PPG-2512-D7211Janoshik2026-Q299.665.1192.5Buyer-sourced0PASS