AssayIndex

AX-2026-042875

TB-500 · 10 mg declared · Nantong Guangyuan Chemical Co., Ltd. · lot GGPE-2601-B2671

PASSVERIFIED
Report ID
AX-2026-042875
Compound
TB-500
Compound class
Tissue-repair and immunomodulatory peptides
Supplier
GGPeps — Nantong Guangyuan Chemical Co., Ltd.
Batch / lot
GGPE-2601-B2671
Declared label claim
10mg
Laboratory
Nordanalyt Laboratories
Assay date
31 May 2026
Submitted
18 Jun 2026
Quarter
2026-Q2
Submitter
r.kjaer
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the tissue-repair and immunomodulatory peptides class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 35 min gradient, 214 nm99.57% area≥ 98.5PASS
Total impuritiesRP-HPLC, sum of reported peaks0.43% area≤ 1.5PASS
Largest single impurityRP-HPLC — C-terminal amide (−1 Da)0.29% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula887.4964DaNOT TESTED
Identity — observed monoisotopic massLC-MS, high resolution (ESI-TOF/QTOF)887.4976DaNOT TESTED
Mass accuracyobserved vs theoretical+1.3ppm± 15PASS
Peptide contentnot ordered on this submissionnot determinedrequired to check label claimNOT TESTED
Water contentKarl Fischer, coulometric, duplicate4.05%≤ 10.0PASS
Counter-ion (acetate)anion-exchange ion chromatography6.03%≤ 12.0PASS
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.84%NOT TESTED
Endotoxinkinetic chromogenic LAL0.38EU/mg≤ 5.0PASS
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration5.612.5 – 8.0PASS
Retention time (observed)RP-HPLC, 35 min gradient9.14min9.07 ± 0.25 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.460.950.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²58,195≥ 20,000PASS
Resolution to nearest impurityvs [D-Thr]-diastereomer0.83no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

031206240936012480 TB-5009.14 min · 99.57 % 9.35 same trace · ×200 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 0510152025303540 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 35 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 58,195, and skew follows the reported asymmetry factor of 0.95. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.29 % impurity against a 99.57 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1TB-500 — main peak9.144,839,41199.57
2C-terminal amide (−1 Da)9.3514,0950.29-0.984
3[D-Thr]-diastereomer9.014,3740.090.000
4des-Gln truncate (−128 Da)8.861,4580.03-128.059
5des-acetyl TB-500 (−42 Da)8.539720.02-42.011
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 887.4964 Da, computed from C39H69N9O14. All ppm figures on this site are against monoisotopic values — see why that matters.

0255075100375475575675775875975 [M+1H]1+888.50[M+2H]2+444.76 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, high-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 887.4976 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
2+444.7555444.75610.000653.9
1+888.5037888.50490.0012100.0
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.6099.57divergence +0.01 pp vs batch median
Total impurities (% area)0.400.43
Largest single impurity (% area)not stated0.29
Water (%)2.84.05
Counter-ion (%)not stated6.03
Peptide content (%w/w)98.0not determined
Endotoxin (EU/mg)not stated0.38
Method stated on certificateNOno method section — the result cannot be reconciled against any other
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → submitter (ambient, 6 d) → laboratory (courier, cold pack, 4 d) → assay.
Assay date
31 May 2026
Submitted to the index
18 Jun 2026
Laboratory
Nordanalyt Laboratories, Uppsala, Sweden
Method basis
35 min gradient · high-resolution MS
Verification status
VERIFIED
Section 6

Annotations 2

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

units_pedant
Reported as signed ppm, which is the right convention: direction carries information about calibration that a modulus discards.
lambda_214
Detection wavelength does not affect a mass determination but it does affect the purity figure sitting next to it. Both are stated on this record, which is the point.
Section 7

Related records

Same batch — lot GGPE-2601-B2671 n=13

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042870GGPE-2601-B2671Janoshik2026-Q299.214.4588.9Buyer-sourced1MARGINAL
AX-2026-042871GGPE-2601-B2671PeptideMeter2026-Q299.934.8589.7Supplier-supplied1MARGINAL
AX-2026-042872GGPE-2601-B2671Medutest2026-Q299.805.2692.5Buyer-sourced0PASS
AX-2026-042873GGPE-2601-B2671Janoshik2026-Q299.304.92103.1Buyer-sourced0PASS
AX-2026-042874GGPE-2601-B2671Janoshik2026-Q299.594.96104.3Buyer-sourced0PASS
AX-2026-042876GGPE-2601-B2671PeptideMeter2026-Q299.434.24Buyer-sourced0PASS
AX-2026-042877GGPE-2601-B2671Janoshik2026-Q299.675.07105.8Buyer-sourced0PASS
AX-2026-042878GGPE-2601-B2671Janoshik2026-Q299.774.87Buyer-sourced1FAIL
AX-2026-042879GGPE-2601-B2671Medutest2026-Q299.934.4298.8Supplier-supplied0PASS
AX-2026-042880GGPE-2601-B2671Janoshik2026-Q299.254.89Buyer-sourced0PASS
AX-2026-042881GGPE-2601-B2671Janoshik2026-Q299.694.50Buyer-sourced0PASS
AX-2026-042882GGPE-2601-B2671VendorInvestigate2026-Q299.505.12Buyer-sourced0PASS
Other recent TB-500 records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041776ASYASY-{CAT}-2167Janoshik2026-Q399.924.6198.2Buyer-sourced0PASS
AX-2026-041777ASYASY-{CAT}-2167PeptideMeter2026-Q399.784.0992.8Buyer-sourced0PASS
AX-2026-041782ASYASY-{CAT}-2167Nordanalyt2026-Q399.933.94Buyer-sourced0PASS
AX-2026-041774ASYASY-{CAT}-2167PeptideMeter2026-Q399.934.4196.2Buyer-sourced0PASS
AX-2026-042127JEEPJEEP-2602-V8614Medutest2026-Q399.683.55Buyer-sourced1FAIL
AX-2026-042021AMBAMB-2602-P5987VendorInvestigate2026-Q399.864.79101.4Buyer-sourced0PASS
AX-2026-041780ASYASY-{CAT}-2167Janoshik2026-Q399.933.48102.5Buyer-sourced1FAIL
AX-2026-041779ASYASY-{CAT}-2167Janoshik2026-Q399.843.85Buyer-sourced1FAIL
Other recent GGPeps records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042784CJC-1295 (no DAC)GGPE-2606-E1234Medutest2026-Q398.274.55Buyer-sourced0PASS
AX-2026-042786CJC-1295 (no DAC)GGPE-2606-E1234Janoshik2026-Q398.223.77Buyer-sourced0PASS
AX-2026-042858SelankGGPE-2603-J2447VendorInvestigate2026-Q398.878.8599.4Buyer-sourced0FAIL
AX-2026-042783CJC-1295 (no DAC)GGPE-2606-E1234Janoshik2026-Q398.224.4590.6Buyer-sourced0PASS
AX-2026-042757Melanotan IIGGPE-2603-P1474Janoshik2026-Q399.546.7892.0Buyer-sourced0PASS
AX-2026-042785CJC-1295 (no DAC)GGPE-2606-E1234PeptideMeter2026-Q397.704.6491.4Buyer-sourced0FAIL
AX-2026-042756Melanotan IIGGPE-2603-P1474Nordanalyt2026-Q399.177.04Buyer-sourced0PASS
AX-2026-042755Melanotan IIGGPE-2603-P1474Nordanalyt2026-Q399.256.5890.4Buyer-sourced0PASS