AssayIndex

AX-2026-042508

IGF-1 LR3 · 0.1 mg declared · Hunan Aslsen Technology Co., Ltd. · lot HOMO-2607-P5131

MARGINALIDENTITY CONSISTENT
Report ID
AX-2026-042508
Compound
IGF-1 LR3
Compound class
Growth-hormone axis peptides
Supplier
Homopeptide — Hunan Aslsen Technology Co., Ltd.
Batch / lot
HOMO-2607-P5131
Declared label claim
0.10mg
Laboratory
Janoshik Analytical
Assay date
18 Aug 2026
Submitted
05 Sep 2026
Quarter
2026-Q3
Submitter
b.espinoza
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the growth-hormone axis peptides class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 30 min gradient, 214 nm98.89% area≥ 95.0PASS
Total impuritiesRP-HPLC, sum of reported peaks1.11% area≤ 5.0PASS
Largest single impurityRP-HPLC — disulfide-scrambled isomer0.48% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula9105.2412DaNOT TESTED
Identity — observed monoisotopic massLC-MS, high resolution (ESI-TOF/QTOF)9105.2703DaNOT TESTED
Mass accuracyobserved vs theoretical+3.2ppm± 15PASS
Peptide contentnot ordered on this submissionnot determinedrequired to check label claimNOT TESTED
Water contentKarl Fischer, coulometric, duplicate6.22%≤ 9.0PASS
Counter-ion (acetate)anion-exchange ion chromatography3.99%≤ 12.0PASS
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.57%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear after 90 s gentle swirling, no particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration5.092.5 – 8.0PASS
Retention time (observed)RP-HPLC, 30 min gradient15.79min16.92 ± 0.50 (normalised)FAIL
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.150.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²57,262≥ 20,000PASS
Resolution to nearest impurityvs disulfide-scrambled isomer2.29no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

01614322848416455 IGF-1 LR315.79 min · 98.89 % 16.4113.5518.99 same trace · ×100 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 05101520253035 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 30 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 57,262, and skew follows the reported asymmetry factor of 1.15. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.48 % impurity against a 98.89 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1IGF-1 LR3 — main peak15.794,806,36198.89
2disulfide-scrambled isomer16.4123,3290.480.000
3oxidised Met59 (+16 Da)15.0717,4970.36+15.995
4des-13-residue N-extension (native IGF-1)13.558,2630.17-1441.712
5truncated (1-70)13.852,9160.06-1385.688
6aggregated dimer18.991,9440.04+9105.241
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 9105.2412 Da, computed from C400H625N111O116S9. All ppm figures on this site are against monoisotopic values — see why that matters.

02550751007508509501050115012501350 [M+9H]9+1012.70[M+8H]8+1139.17[M+10H]10+911.53 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, high-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 9105.2703 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
11+828.7565828.75910.00267.6
10+911.5314911.53430.002953.1
9+1012.70071012.70400.0033100.0
8+1139.16241139.16610.003757.1
7+1301.75601301.76020.00428.5
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)98.9798.89divergence +0.04 pp vs batch median
Total impurities (% area)not stated1.11
Largest single impurity (% area)not stated0.48
Water (%)6.06.22
Counter-ion (%)not stated3.99
Peptide content (%w/w)89.2not determined
Endotoxin (EU/mg)0.71not determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Domestic warehouse despatch → submitter (2–8 °C, 28 d) → laboratory (courier, cold pack, 5 d) → assay.
Assay date
18 Aug 2026
Submitted to the index
05 Sep 2026
Laboratory
Janoshik Analytical, Ostrava, Czechia
Method basis
30 min gradient · high-resolution MS
Verification status
IDENTITY CONSISTENT
Section 6

Annotations 2

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

sole_source
On compounds with a single supplier, independently purchased records are the only thing preventing the evidence base from being entirely supplier-generated. They matter disproportionately there.
gradient_25
Normalisation assumes the gradient was linear and ran to completion. A method with an isocratic hold at the start breaks the assumption and the certificate will not mention the hold.
Section 7

Related records

Same batch — lot HOMO-2607-P5131 n=14

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042497HOMO-2607-P5131Janoshik2026-Q398.896.25Buyer-sourced0PASS
AX-2026-042498HOMO-2607-P5131PeptideMeter2026-Q399.095.99105.0Buyer-sourced0PASS
AX-2026-042499HOMO-2607-P5131Medutest2026-Q398.485.9888.0Buyer-sourced1MARGINAL
AX-2026-042500HOMO-2607-P5131Janoshik2026-Q398.976.1786.0Supplier-supplied1MARGINAL
AX-2026-042501HOMO-2607-P5131Janoshik2026-Q398.897.00Buyer-sourced0PASS
AX-2026-042502HOMO-2607-P5131Kestrel2026-Q399.366.3996.0Buyer-sourced0PASS
AX-2026-042503HOMO-2607-P5131Janoshik2026-Q399.365.99Buyer-sourced0PASS
AX-2026-042504HOMO-2607-P5131Janoshik2026-Q399.086.26105.0Buyer-sourced0PASS
AX-2026-042505HOMO-2607-P5131PeptideMeter2026-Q398.736.03Buyer-sourced0PASS
AX-2026-042506HOMO-2607-P5131PeptideMeter2026-Q398.586.21Buyer-sourced0PASS
AX-2026-042507HOMO-2607-P5131Medutest2026-Q399.266.2888.0Buyer-sourced1MARGINAL
AX-2026-042509HOMO-2607-P5131Medutest2026-Q398.636.23103.0Buyer-sourced0PASS
AX-2026-042510HOMO-2607-P5131Janoshik2026-Q399.006.3695.0Buyer-sourced0FAIL
Other recent IGF-1 LR3 records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042503HomopeptideHOMO-2607-P5131Janoshik2026-Q399.365.99Buyer-sourced0PASS
AX-2026-042509HomopeptideHOMO-2607-P5131Medutest2026-Q398.636.23103.0Buyer-sourced0PASS
AX-2026-041930SinoPepSNP-2606-D4620Medutest2026-Q398.545.3793.8Buyer-sourced0PASS
AX-2026-041931SinoPepSNP-2606-D4620PeptideMeter2026-Q397.935.1993.4Buyer-sourced0PASS
AX-2026-041924SinoPepSNP-2606-D4620Janoshik2026-Q397.955.34Buyer-sourced0PASS
AX-2026-042504HomopeptideHOMO-2607-P5131Janoshik2026-Q399.086.26105.0Buyer-sourced0PASS
AX-2026-042499HomopeptideHOMO-2607-P5131Medutest2026-Q398.485.9888.0Buyer-sourced1MARGINAL
AX-2026-041926SinoPepSNP-2606-D4620VendorInvestigate2026-Q398.745.4598.9Buyer-sourced0PASS
Other recent Homopeptide records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042437RetatrutideHOMO-2605-V4718Nordanalyt2026-Q398.683.67102.8Buyer-sourced0PASS
AX-2026-042424SemaglutideHOMO-2604-X3806PeptideMeter2026-Q398.854.8792.0Buyer-sourced0PASS
AX-2026-042503IGF-1 LR3HOMO-2607-P5131Janoshik2026-Q399.365.99Buyer-sourced0PASS
AX-2026-042492SS-31 (Elamipretide)HOMO-2604-D5484Medutest2026-Q399.932.40Buyer-sourced0PASS
AX-2026-042491SS-31 (Elamipretide)HOMO-2604-D5484Kestrel2026-Q399.933.24Supplier-supplied0PASS
AX-2026-042473LL-37HOMO-2602-G5165Janoshik2026-Q399.015.00Buyer-sourced0PASS
AX-2026-042441RetatrutideHOMO-2605-V4718Medutest2026-Q398.934.22Buyer-sourced0PASS
AX-2026-042474LL-37HOMO-2602-G5165Janoshik2026-Q399.185.44Buyer-sourced0PASS