AssayIndex

AX-2026-041418

BPC-157 · 2 mg declared · ChinaPeptides Co., Ltd. (QYAOBIO) · lot QYB-2510-R4608

PASSVERIFIED
Report ID
AX-2026-041418
Compound
BPC-157
Compound class
Tissue-repair and immunomodulatory peptides
Supplier
QYB — ChinaPeptides Co., Ltd. (QYAOBIO)
Batch / lot
QYB-2510-R4608
Declared label claim
2mg
Laboratory
Janoshik Analytical
Assay date
19 Feb 2026
Submitted
17 Mar 2026
Quarter
2026-Q1
Submitter
gc_headspace
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the tissue-repair and immunomodulatory peptides class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 30 min gradient, 214 nm99.77% area≥ 98.0PASS
Total impuritiesRP-HPLC, sum of reported peaks0.23% area≤ 2.0PASS
Largest single impurityRP-HPLC — des-Gly truncate (−57 Da)0.15% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula1418.7093DaNOT TESTED
Identity — observed monoisotopic massLC-MS, high resolution (ESI-TOF/QTOF)1418.7153DaNOT TESTED
Mass accuracyobserved vs theoretical+4.2ppm± 15PASS
Peptide contentnot ordered on this submissionnot determinedrequired to check label claimNOT TESTED
Water contentKarl Fischer, coulometric, duplicate6.93%≤ 10.0PASS
Counter-ion (acetate)anion-exchange ion chromatography8.67%≤ 12.0PASS
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.43%NOT TESTED
Endotoxinkinetic chromogenic LAL1.06EU/mg≤ 5.0PASS
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear after 90 s gentle swirling, no particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration4.862.5 – 8.0PASS
Retention time (observed)RP-HPLC, 30 min gradient9.68min9.62 ± 0.25 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.110.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²68,105≥ 20,000PASS
Resolution to nearest impurityvs [D-Val]-diastereomer0.92no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

029515903885411805 BPC-1579.68 min · 99.77 % 9.34 same trace · ×200 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 05101520253035 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 30 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 68,105, and skew follows the reported asymmetry factor of 1.11. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.15 % impurity against a 99.77 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1BPC-157 — main peak9.684,849,13199.77
2des-Gly truncate (−57 Da)9.347,2900.15-57.021
3[D-Val]-diastereomer9.541,9440.040.000
4acetylated N-terminus (+42 Da)10.161,9440.04+42.011
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 1418.7093 Da, computed from C62H98N16O22. All ppm figures on this site are against monoisotopic values — see why that matters.

0255075100350550750950115013501550 [M+1H]1+1419.72[M+2H]2+710.36 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, high-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 1418.7153 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
3+473.9104473.91240.00208.6
2+710.3619710.36490.003053.3
1+1419.71661419.72260.0060100.0
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.1599.77divergence -0.67 pp vs batch median
Total impurities (% area)not stated0.23
Largest single impurity (% area)not stated0.15
Water (%)not stated6.93
Counter-ion (%)7.88.67
Peptide content (%w/w)88.1not determined
Endotoxin (EU/mg)0.731.06
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → submitter (ambient, 21 d) → laboratory (hand-carried, 5 d) → assay.
Assay date
19 Feb 2026
Submitted to the index
17 Mar 2026
Laboratory
Janoshik Analytical, Ostrava, Czechia
Method basis
30 min gradient · high-resolution MS
Verification status
VERIFIED
Section 6

Annotations 3

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

sig_figs
Two decimal places on 99.77 % implies repeatability better than 0.01 pp, which no laboratory here claims. The number is sound; the printed precision is more than the method carries.
Index data team

Two decimal places are retained because the source reports carry them and truncating would discard information where a laboratory genuinely reports it. The uncertainty budget on /methods/uncertainty-budget/ is the right thing to read alongside any purity figure on this site.

des_gly
At 99.77 % the deletion-sequence family is at or below the reporting threshold. On a sequence with a hindered coupling that is a statement about coupling efficiency, and a good one.
c18_2p6
Column chemistry flatters or punishes a figure like this. A core-shell column at this gradient resolves the close-eluting family that a fully porous 5 µm bed merges, so 99.77 % here is a harder number than the same figure from a coarser column.
Section 7

Related records

Same batch — lot QYB-2510-R4608 n=6

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041417QYB-2510-R4608Nordanalyt2026-Q199.876.86Buyer-sourced0PASS
AX-2026-041419QYB-2510-R4608PeptideMeter2026-Q199.476.8796.2Buyer-sourced0PASS
AX-2026-041420QYB-2510-R4608VendorInvestigate2026-Q199.916.9391.9Buyer-sourced0PASS
AX-2026-041421QYB-2510-R4608Janoshik2026-Q199.717.13102.6Laboratory-retained0PASS
AX-2026-041422QYB-2510-R4608Janoshik2026-Q199.936.37Buyer-sourced0PASS
Other recent BPC-157 records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043319CPCCPC-2602-W1610Medutest2026-Q398.822.88103.5Buyer-sourced2MARGINAL
AX-2026-041766TFSTFS-{CAT}-1156Janoshik2026-Q399.546.34Buyer-sourced1MARGINAL
AX-2026-043445BCHBCH-2603-G4350Nordanalyt2026-Q398.424.8793.6Buyer-sourced1MARGINAL
AX-2026-043440BCHBCH-2603-G4350VendorInvestigate2026-Q398.614.11Buyer-sourced1MARGINAL
AX-2026-043442BCHBCH-2603-G4350Janoshik2026-Q398.654.78Buyer-sourced1MARGINAL
AX-2026-043449BCHBCH-2603-G4350Kestrel2026-Q399.744.9291.3Supplier-supplied2MARGINAL
AX-2026-043448BCHBCH-2603-G4350Janoshik2026-Q398.554.69106.9Buyer-sourced1MARGINAL
AX-2026-043318CPCCPC-2602-W1610VendorInvestigate2026-Q398.473.12104.1Buyer-sourced1MARGINAL
Other recent QYB records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041471PT-141 (Bremelanotide)QYB-2607-L4875Janoshik2026-Q399.723.75101.7Buyer-sourced0PASS
AX-2026-041377IpamorelinQYB-2605-H3558Nordanalyt2026-Q399.934.35Buyer-sourced0PASS
AX-2026-041427RetatrutideQYB-2604-B4920PeptideMeter2026-Q397.932.45101.7Buyer-sourced0PASS
AX-2026-041428RetatrutideQYB-2604-B4920Janoshik2026-Q398.353.20Laboratory-retained0PASS
AX-2026-041473PT-141 (Bremelanotide)QYB-2607-L4875PeptideMeter2026-Q399.583.7494.4Buyer-sourced0PASS
AX-2026-041472PT-141 (Bremelanotide)QYB-2607-L4875PeptideMeter2026-Q399.933.94Buyer-sourced0PASS
AX-2026-041429RetatrutideQYB-2604-B4920Medutest2026-Q398.532.6999.8Buyer-sourced1MARGINAL