AssayIndex

AX-2025-020888

5-Amino-1MQ · 100 mg declared · WuXi TIDES (WuXi AppTec Testing Division) · lot WXT-2505-M2430

FAILPURITY ONLY
Report ID
AX-2025-020888
Compound
5-Amino-1MQ
Compound class
Non-peptide adjuncts
Supplier
WXT — WuXi TIDES (WuXi AppTec Testing Division)
Batch / lot
WXT-2505-M2430
Declared label claim
100mg
Laboratory
Janoshik Analytical
Assay date
15 May 2025
Submitted
22 May 2025
Quarter
2025-Q2
Submitter
am.hartmann
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the non-peptide adjuncts class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 30 min gradient, 214 nm98.51% area≥ 98.0PASS
Total impuritiesRP-HPLC, sum of reported peaks1.49% area≤ 2.0PASS
Largest single impurityRP-HPLC — 1-methylquinolinium (des-amino, −15 Da)1.07% area≤ 1.00FAIL
Identitynot ordered on this submissionnot determinedrequired for VERIFIED statusNOT TESTED
Total peptide contentby difference from the gravimetric mass balance54.28%w/wNOT TESTED
Target-compound contenttotal peptide content × purity53.47%w/wNOT TESTED
Gross fill (as weighed)five-place balance, under nitrogen167.24mg100 mg declaredNOT TESTED
Recovered target peptidegross fill × target content89.423mg100 mg claimNOT TESTED
Recovery against label claimrecovered ÷ claim89.4%90.0 – 110.0FAIL
Water contentKarl Fischer, coulometric, duplicate2.75%≤ 10.0PASS
Counter-ion (iodide)anion-exchange ion chromatography42.51%≤ 12.0FAIL
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.46%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundOff-white lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration5.292.5 – 8.0PASS
Retention time (observed)RP-HPLC, 30 min gradient5.61min5.42 ± 0.25 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.460.860.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²68,458≥ 20,000PASS
Resolution to nearest impurityvs free iodide (counter-ion, by IC)0.00no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

05604112081681222416 5-Amino-1MQ5.61 min · 98.51 % 5.29 same trace · ×50 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 05101520253035 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 30 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 68,458, and skew follows the reported asymmetry factor of 0.86. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 1.07 % impurity against a 98.51 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
15-Amino-1MQ — main peak5.614,787,89198.51
21-methylquinolinium (des-amino, −15 Da)5.2952,0051.07-15.011
38-amino regioisomer5.8311,6650.240.000
4free iodide (counter-ion, by IC)5.614,8600.100.000
55-nitro-1MQ (unreduced precursor, +30 Da)6.293,8880.08+29.974
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

ComponentDetermination%w/w of cake
WaterKarl Fischer2.75
Counter-ion (iodide)ion chromatography42.51
Residual solvent + inorganic residueestimated0.46
Total peptide contentby difference54.28
Total100.00 CLOSES

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.0998.51divergence +0.38 pp vs batch median
Total impurities (% area)0.911.49
Largest single impurity (% area)0.511.07
Water (%)not stated2.75
Counter-ion (%)7.942.51
Peptide content (%w/w)88.054.28
Endotoxin (EU/mg)not statednot determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → submitter (ambient, 18 d) → laboratory (courier, cold pack, 12 d) → assay.
Assay date
15 May 2025
Submitted to the index
22 May 2025
Laboratory
Janoshik Analytical, Ostrava, Czechia
Method basis
30 min gradient · high-resolution MS
Verification status
PURITY ONLY
Section 6

Annotations 4

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

chain_custody
A retail vial at 98.51 % is worth more evidentially than a selected vial at a higher figure. That is the whole argument for recording provenance at all.
sample_vs_retail
Where a supplier-supplied result on the same lot also exists, the pair is the informative object rather than either record alone. The batch page shows whether one does.
buyer_sourced
Anyone can generate one of these. That is the argument the index makes on its submission page and it is the reason the dataset grows without any supplier's cooperation.
gradient_25
Nothing on this record is flagged for resolution and nothing will be. The figure exists so the reader can weight the purity number, which is its only purpose.
Section 7

Related records

Same batch — lot WXT-2505-M2430 n=9

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-020883WXT-2505-M2430Janoshik2025-Q298.712.6690.2Buyer-sourced0FAIL
AX-2025-020884WXT-2505-M2430Medutest2025-Q298.742.93102.5Buyer-sourced0FAIL
AX-2025-020885WXT-2505-M2430Medutest2025-Q299.082.4689.1Supplier-supplied1FAIL
AX-2025-020886WXT-2505-M2430Nordanalyt2025-Q299.342.7798.0Supplier-supplied0FAIL
AX-2025-020887WXT-2505-M2430Janoshik2025-Q298.192.78Buyer-sourced0FAIL
AX-2025-020889WXT-2505-M2430VendorInvestigate2025-Q297.982.57Buyer-sourced0FAIL
AX-2025-020890WXT-2505-M2430Medutest2025-Q298.272.90100.5Buyer-sourced0FAIL
AX-2025-020891WXT-2505-M2430VendorInvestigate2025-Q298.803.32104.8Buyer-sourced0FAIL
Other recent 5-Amino-1MQ records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043050KPKP-2511-W5347Janoshik2026-Q299.354.16105.5Buyer-sourced0FAIL
AX-2026-043044KPKP-2511-W5347PeptideMeter2026-Q299.614.1590.9Buyer-sourced0FAIL
AX-2026-043052KPKP-2511-W5347Medutest2026-Q299.454.23105.5Buyer-sourced1FAIL
AX-2026-043045KPKP-2511-W5347Janoshik2026-Q299.474.08Buyer-sourced0FAIL
AX-2026-043043KPKP-2511-W5347Janoshik2026-Q299.584.16101.1Buyer-sourced0FAIL
AX-2026-042869GGPepsGGPE-2512-M2434Kestrel2026-Q299.554.65103.9Buyer-sourced0FAIL
AX-2026-042868GGPepsGGPE-2512-M2434PeptideMeter2026-Q299.324.3988.5Buyer-sourced1FAIL
AX-2026-043047KPKP-2511-W5347Janoshik2026-Q299.684.17104.0Supplier-supplied0FAIL
Other recent WXT records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043376SemaglutideWXT-2604-C3248Janoshik2026-Q397.084.22Buyer-sourced1MARGINAL
AX-2026-043429L-Glutathione (reduced)WXT-2605-B3833Nordanalyt2026-Q398.486.5896.9Supplier-supplied1FAIL
AX-2026-043347LeuprolideWXT-2604-K2596PeptideMeter2026-Q399.165.9993.6Buyer-sourced0PASS
AX-2026-043353LeuprolideWXT-2604-K2596Janoshik2026-Q399.194.9095.3Laboratory-retained0PASS
AX-2026-043345LeuprolideWXT-2604-K2596Janoshik2026-Q398.935.28Buyer-sourced0PASS
AX-2026-043424L-Glutathione (reduced)WXT-2605-B3833PeptideMeter2026-Q398.376.86Buyer-sourced0FAIL
AX-2026-043374SemaglutideWXT-2604-C3248Janoshik2026-Q397.003.56Buyer-sourced1MARGINAL
AX-2026-043377SemaglutideWXT-2604-C3248PeptideMeter2026-Q397.204.08Buyer-sourced1MARGINAL