AssayIndex

AX-2025-020606

BPC-157 · 2 mg declared · Shanghai Sigma-Audley New Material Technology Co., Ltd. · lot SSA-2505-J7334

MARGINALPURITY ONLY
Report ID
AX-2025-020606
Compound
BPC-157
Compound class
Tissue-repair and immunomodulatory peptides
Supplier
SSA — Shanghai Sigma-Audley New Material Technology Co., Ltd.
Batch / lot
SSA-2505-J7334
Declared label claim
2mg
Laboratory
Janoshik Analytical
Assay date
20 Sep 2025
Submitted
14 Oct 2025
Quarter
2025-Q3
Submitter
mi.villalobos
Sample provenance
Supplier-supplied
Section 1

Results

Measured against the index acceptance specification for the tissue-repair and immunomodulatory peptides class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 30 min gradient, 214 nm99.08% area≥ 98.0PASS
Total impuritiesRP-HPLC, sum of reported peaks0.92% area≤ 2.0PASS
Largest single impurityRP-HPLC — des-Gly truncate (−57 Da)0.51% area≤ 1.00PASS
Identitynot ordered on this submissionnot determinedrequired for VERIFIED statusNOT TESTED
Total peptide contentby difference from the gravimetric mass balance89.63%w/wNOT TESTED
Target-compound contenttotal peptide content × purity88.81%w/wNOT TESTED
Gross fill (as weighed)five-place balance, under nitrogen2.01mg2 mg declaredNOT TESTED
Recovered target peptidegross fill × target content1.785mg2 mg claimNOT TESTED
Recovery against label claimrecovered ÷ claim89.3%90.0 – 110.0FAIL
Water contentKarl Fischer, coulometric, duplicate2.72%≤ 10.0PASS
Counter-ion (acetate)anion-exchange ion chromatography7.47%≤ 12.0PASS
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.18%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration5.412.5 – 8.0PASS
Retention time (observed)RP-HPLC, 30 min gradient9.63min9.62 ± 0.25 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.030.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²47,582≥ 20,000PASS
Resolution to nearest impurityvs [D-Val]-diastereomer0.77no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

025605119767910238 BPC-1579.63 min · 99.08 % 9.29 same trace · ×100 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 05101520253035 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 30 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 47,582, and skew follows the reported asymmetry factor of 1.03. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.51 % impurity against a 99.08 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1BPC-157 — main peak9.634,815,59599.08
2des-Gly truncate (−57 Da)9.2924,7880.51-57.021
3pyroglutamate cyclisation (−17 Da)9.9411,6650.24-17.027
4acetylated N-terminus (+42 Da)10.115,3460.11+42.011
5[D-Val]-diastereomer9.491,4580.030.000
6truncated (1-12)8.671,4580.03-285.132
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

ComponentDetermination%w/w of cake
WaterKarl Fischer2.72
Counter-ion (acetate)ion chromatography7.47
Residual solvent + inorganic residueestimated0.18
Total peptide contentby difference89.63
Total100.00 CLOSES

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)98.4099.08divergence -0.24 pp vs batch median
Total impurities (% area)not stated0.92
Largest single impurity (% area)not stated0.51
Water (%)1.12.72
Counter-ion (%)not stated7.47
Peptide content (%w/w)not stated89.63
Endotoxin (EU/mg)not statednot determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Supplier-supplied
Evidentiary weight
Weaker evidence. Read with the caveat below.
Chain of custody
Supplier despatch → laboratory direct (courier, cold pack, 5 d) → assay. Submitter did not handle the vial.
Assay date
20 Sep 2025
Submitted to the index
14 Oct 2025
Laboratory
Janoshik Analytical, Ostrava, Czechia
Method basis
30 min gradient · high-resolution MS
Verification status
PURITY ONLY
Section 6

Annotations 3

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

sample_vs_retail
Supplier-supplied provenance. Across the 300 lots in this index where both classes exist for the same lot, supplier-supplied results read a mean 0.42 pp higher (95 % CI 0.38 to 0.46). Read 99.08 % as an optimistic bound rather than a point estimate.
survivor_lots
A supplier sending a sample chooses a lot as well as a vial. Both selections point the same way and neither is separable from the other in a single record.
valley_drop
des-Gly truncate (−57 Da) at 0.51 % elutes close enough to the main peak that drop-line and valley-to-valley will not agree. The index prints the resolution figure and applies no criterion to it — how close the nearest impurity sits is a property of the compound and the gradient, not of the system. What matters is that the convention used is stated.
Section 7

Related records

Same batch — lot SSA-2505-J7334 n=8

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-020604SSA-2505-J7334PeptideMeter2025-Q398.363.46Buyer-sourced1MARGINAL
AX-2025-020605SSA-2505-J7334Janoshik2025-Q398.393.4792.4Buyer-sourced1MARGINAL
AX-2025-020607SSA-2505-J7334Medutest2025-Q398.613.01Laboratory-retained1MARGINAL
AX-2025-020608SSA-2505-J7334Janoshik2025-Q398.753.7397.9Buyer-sourced1MARGINAL
AX-2025-020609SSA-2505-J7334Nordanalyt2025-Q398.663.2792.9Buyer-sourced1MARGINAL
AX-2025-020610SSA-2505-J7334Janoshik2025-Q398.243.11Buyer-sourced1MARGINAL
AX-2025-020611SSA-2505-J7334Janoshik2025-Q398.773.76Laboratory-retained1MARGINAL
Other recent BPC-157 records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043319CPCCPC-2602-W1610Medutest2026-Q398.822.88103.5Buyer-sourced2MARGINAL
AX-2026-041766TFSTFS-{CAT}-1156Janoshik2026-Q399.546.34Buyer-sourced1MARGINAL
AX-2026-043445BCHBCH-2603-G4350Nordanalyt2026-Q398.424.8793.6Buyer-sourced1MARGINAL
AX-2026-043440BCHBCH-2603-G4350VendorInvestigate2026-Q398.614.11Buyer-sourced1MARGINAL
AX-2026-043442BCHBCH-2603-G4350Janoshik2026-Q398.654.78Buyer-sourced1MARGINAL
AX-2026-043449BCHBCH-2603-G4350Kestrel2026-Q399.744.9291.3Supplier-supplied2MARGINAL
AX-2026-043448BCHBCH-2603-G4350Janoshik2026-Q398.554.69106.9Buyer-sourced1MARGINAL
AX-2026-043318CPCCPC-2602-W1610VendorInvestigate2026-Q398.473.12104.1Buyer-sourced1MARGINAL
Other recent SSA records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043135BPC-157SSA-2601-N6863Nordanalyt2026-Q298.164.6692.8Buyer-sourced1MARGINAL
AX-2026-043160GHK-CuSSA-2604-V7731Janoshik2026-Q298.014.0291.8Buyer-sourced0PASS
AX-2026-043157GHK-CuSSA-2604-V7731Medutest2026-Q299.195.14Supplier-supplied0PASS
AX-2026-043141BPC-157SSA-2601-N6863Janoshik2026-Q298.064.0694.6Buyer-sourced1MARGINAL
AX-2026-043154GHK-CuSSA-2604-V7731PeptideMeter2026-Q297.824.82101.6Buyer-sourced0PASS
AX-2026-043137BPC-157SSA-2601-N6863PeptideMeter2026-Q298.174.14Buyer-sourced1MARGINAL
AX-2026-043162GHK-CuSSA-2604-V7731Janoshik2026-Q298.504.36Supplier-supplied0PASS
AX-2026-043134BPC-157SSA-2601-N6863Medutest2026-Q297.894.01Buyer-sourced1FAIL