AssayIndex

AX-2025-020365

5-Amino-1MQ · 100 mg declared · Xi'an Mokemei Biotechnology Co., Ltd. · lot MKM-2503-H3929

FAILIDENTITY CONSISTENT
Report ID
AX-2025-020365
Compound
5-Amino-1MQ
Compound class
Non-peptide adjuncts
Supplier
MKM — Xi'an Mokemei Biotechnology Co., Ltd.
Batch / lot
MKM-2503-H3929
Declared label claim
100mg
Laboratory
Kestrel Bioanalytical
Assay date
16 Aug 2025
Submitted
24 Aug 2025
Quarter
2025-Q3
Submitter
a.balogun
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the non-peptide adjuncts class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 15 min gradient, 214 nm99.86% area≥ 98.0PASS
Total impuritiesRP-HPLC, sum of reported peaks0.14% area≤ 2.0PASS
Largest single impurityRP-HPLC — 1-methylquinolinium (des-amino, −15 Da)0.09% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula285.9967DaNOT TESTED
Identity — observed monoisotopic massLC-MS, unit resolution (single quadrupole)285.9946DaNOT TESTED
Mass accuracyobserved vs theoretical-7.4ppm± 10PASS
Total peptide contentby difference from the gravimetric mass balance49.16%w/wNOT TESTED
Target-compound contenttotal peptide content × purity49.09%w/wNOT TESTED
Gross fill (as weighed)five-place balance, under nitrogen198.13mg100 mg declaredNOT TESTED
Recovered target peptidegross fill × target content97.262mg100 mg claimNOT TESTED
Recovery against label claimrecovered ÷ claim97.3%90.0 – 110.0PASS
Water contentKarl Fischer, coulometric, duplicate5.37%≤ 10.0PASS
Counter-ion (iodide)anion-exchange ion chromatography44.67%≤ 12.0FAIL
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.80%NOT TESTED
Endotoxinkinetic chromogenic LAL1.02EU/mg≤ 5.0PASS
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration5.172.5 – 8.0PASS
Retention time (observed)RP-HPLC, 15 min gradient2.94min2.93 ± 0.25 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.030.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²84,092≥ 20,000PASS
Resolution to nearest impurityvs free iodide (counter-ion, by IC)0.00no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

011235224713370644941 5-Amino-1MQ2.94 min · 99.86 % 2.78 same trace · ×200 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 048121620 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 15 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 84,092, and skew follows the reported asymmetry factor of 1.03. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.09 % impurity against a 99.86 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
15-Amino-1MQ — main peak2.944,853,50699.86
21-methylquinolinium (des-amino, −15 Da)2.784,3740.09-15.011
38-amino regioisomer3.051,4580.030.000
4free iodide (counter-ion, by IC)2.949720.020.000
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 285.9967 Da, computed from C10H11N2+ · I−. All ppm figures on this site are against monoisotopic values — see why that matters.

0255075100250275300325350375 [M+1H]1+287.00 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, unit-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 285.9946 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
1+287.0040287.0019-0.0021100.0
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

ComponentDetermination%w/w of cake
WaterKarl Fischer5.37
Counter-ion (iodide)ion chromatography44.67
Residual solvent + inorganic residueestimated0.80
Total peptide contentby difference49.16
Total100.00 CLOSES

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.8399.86divergence +0.25 pp vs batch median
Total impurities (% area)not stated0.14
Largest single impurity (% area)not stated0.09
Water (%)4.25.37
Counter-ion (%)not stated44.67
Peptide content (%w/w)not stated49.16
Endotoxin (EU/mg)0.641.02
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → submitter (2–8 °C, 15 d) → laboratory (courier, ambient, 9 d) → assay.
Assay date
16 Aug 2025
Submitted to the index
24 Aug 2025
Laboratory
Kestrel Bioanalytical, Melbourne, Australia
Method basis
15 min gradient · unit-resolution MS
Verification status
IDENTITY CONSISTENT
Section 6

Annotations 4

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

area_percent
Area percent assumes unit response factors across every species present. At 99.86 % the assumption barely matters — there is not enough impurity for a response-factor error to move the figure by a tenth.
iso_audit
A certification says what a process is supposed to do. A retail vial says what it did. Both are worth having and only one of them is a measurement.
baseline_noise
On a low-resolution pair the baseline between the peaks never reaches baseline, so any integration is an extrapolation. Stating which extrapolation was used is worth more than any threshold.
gradient_25
Gradient length belongs on every certificate. On a close-eluting pair it is not a detail, it is the whole determination.
Section 7

Related records

Same batch — lot MKM-2503-H3929 n=10

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-020358MKM-2503-H3929Medutest2025-Q399.575.36104.4Buyer-sourced1FAIL
AX-2025-020359MKM-2503-H3929Janoshik2025-Q399.405.12Buyer-sourced0FAIL
AX-2025-020360MKM-2503-H3929Nordanalyt2025-Q399.465.57Buyer-sourced0FAIL
AX-2025-020361MKM-2503-H3929Medutest2025-Q399.594.9294.4Buyer-sourced0FAIL
AX-2025-020362MKM-2503-H3929Janoshik2025-Q399.684.85Buyer-sourced0FAIL
AX-2025-020363MKM-2503-H3929Janoshik2025-Q399.685.5295.1Buyer-sourced0FAIL
AX-2025-020364MKM-2503-H3929PeptideMeter2025-Q399.525.49Buyer-sourced0FAIL
AX-2025-020366MKM-2503-H3929Janoshik2025-Q399.015.45104.3Buyer-sourced0FAIL
AX-2025-020367MKM-2503-H3929Janoshik2025-Q399.705.09106.9Buyer-sourced0FAIL
Other recent 5-Amino-1MQ records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043050KPKP-2511-W5347Janoshik2026-Q299.354.16105.5Buyer-sourced0FAIL
AX-2026-043044KPKP-2511-W5347PeptideMeter2026-Q299.614.1590.9Buyer-sourced0FAIL
AX-2026-043052KPKP-2511-W5347Medutest2026-Q299.454.23105.5Buyer-sourced1FAIL
AX-2026-043045KPKP-2511-W5347Janoshik2026-Q299.474.08Buyer-sourced0FAIL
AX-2026-043043KPKP-2511-W5347Janoshik2026-Q299.584.16101.1Buyer-sourced0FAIL
AX-2026-042869GGPepsGGPE-2512-M2434Kestrel2026-Q299.554.65103.9Buyer-sourced0FAIL
AX-2026-042868GGPepsGGPE-2512-M2434PeptideMeter2026-Q299.324.3988.5Buyer-sourced1FAIL
AX-2026-043047KPKP-2511-W5347Janoshik2026-Q299.684.17104.0Supplier-supplied0FAIL
Other recent MKM records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042942CJC-1295 (no DAC)MKM-2603-V3346Janoshik2026-Q399.523.43Supplier-supplied0PASS
AX-2026-043019AdipotideMKM-2606-K5012Janoshik2026-Q397.615.77105.1Buyer-sourced0PASS
AX-2026-042939CJC-1295 (no DAC)MKM-2603-V3346PeptideMeter2026-Q399.443.39Buyer-sourced0PASS
AX-2026-043020AdipotideMKM-2606-K5012Medutest2026-Q397.735.74Buyer-sourced0PASS
AX-2026-043022AdipotideMKM-2606-K5012Kestrel2026-Q397.696.33106.9Buyer-sourced0PASS
AX-2026-043023AdipotideMKM-2606-K5012Medutest2026-Q397.485.56103.7Supplier-supplied0PASS
AX-2026-042945CJC-1295 (no DAC)MKM-2603-V3346PeptideMeter2026-Q399.393.54Laboratory-retained0PASS
AX-2026-042938CJC-1295 (no DAC)MKM-2603-V3346Nordanalyt2026-Q399.473.6795.0Buyer-sourced0PASS