AssayIndex

AX-2025-019507

5-Amino-1MQ · 50 mg declared · Guangzhou JEEP Biotechnology Co., Ltd. · lot JEEP-2412-M9286

FAILIDENTITY CONSISTENT
Report ID
AX-2025-019507
Compound
5-Amino-1MQ
Compound class
Non-peptide adjuncts
Supplier
JEEP — Guangzhou JEEP Biotechnology Co., Ltd.
Batch / lot
JEEP-2412-M9286
Declared label claim
50mg
Laboratory
Medutest
Assay date
24 Apr 2025
Submitted
27 Apr 2025
Quarter
2025-Q2
Submitter
p.roos
Sample provenance
Supplier-supplied
Section 1

Results

Measured against the index acceptance specification for the non-peptide adjuncts class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 25 min gradient, 214 nm99.93% area≥ 98.0PASS
Total impuritiesRP-HPLC, sum of reported peaks0.07% area≤ 2.0PASS
Largest single impurityRP-HPLC — 5-nitro-1MQ (unreduced precursor, +30 Da)0.04% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula285.9967DaNOT TESTED
Identity — observed monoisotopic massLC-MS, unit resolution (single quadrupole)285.9946DaNOT TESTED
Mass accuracyobserved vs theoretical-7.3ppm± 10PASS
Total peptide contentby difference from the gravimetric mass balance49.44%w/wNOT TESTED
Target-compound contenttotal peptide content × purity49.41%w/wNOT TESTED
Gross fill (as weighed)five-place balance, under nitrogen102.63mg50 mg declaredNOT TESTED
Recovered target peptidegross fill × target content50.709mg50 mg claimNOT TESTED
Recovery against label claimrecovered ÷ claim101.4%90.0 – 110.0PASS
Water contentKarl Fischer, coulometric, duplicate5.57%≤ 10.0PASS
Counter-ion (iodide)anion-exchange ion chromatography44.24%≤ 12.0FAIL
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.75%NOT TESTED
Endotoxinkinetic chromogenic LAL0.32EU/mg≤ 5.0PASS
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite to pale-yellow cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration5.052.5 – 8.0PASS
Retention time (observed)RP-HPLC, 25 min gradient4.54min4.59 ± 0.25 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.010.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²60,202≥ 20,000PASS
Resolution to nearest impurityvs free iodide (counter-ion, by IC)0.00no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

06222124451866724889 5-Amino-1MQ4.54 min · 99.93 % 5.11 same trace · ×200 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 0481216202428 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 25 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 60,202, and skew follows the reported asymmetry factor of 1.01. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.04 % impurity against a 99.93 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
15-Amino-1MQ — main peak4.544,856,90899.93
25-nitro-1MQ (unreduced precursor, +30 Da)5.111,9440.04+29.974
3free iodide (counter-ion, by IC)4.541,4580.030.000
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 285.9967 Da, computed from C10H11N2+ · I−. All ppm figures on this site are against monoisotopic values — see why that matters.

0255075100250275300325350375 [M+1H]1+287.00 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, unit-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 285.9946 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
1+287.0040287.0019-0.0021100.0
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

ComponentDetermination%w/w of cake
WaterKarl Fischer5.57
Counter-ion (iodide)ion chromatography44.24
Residual solvent + inorganic residueestimated0.75
Total peptide contentby difference49.44
Total100.00 CLOSES

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.9099.93divergence -0.03 pp vs batch median
Total impurities (% area)0.100.07
Largest single impurity (% area)0.070.04
Water (%)not stated5.57
Counter-ion (%)not stated44.24
Peptide content (%w/w)not stated49.44
Endotoxin (EU/mg)not stated0.32
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Supplier-supplied
Evidentiary weight
Weaker evidence. Read with the caveat below.
Chain of custody
Supplier despatch → laboratory direct (courier, cold pack, 6 d) → assay. Submitter did not handle the vial.
Assay date
24 Apr 2025
Submitted to the index
27 Apr 2025
Laboratory
Medutest, Ljubljana, Slovenia
Method basis
25 min gradient · unit-resolution MS
Verification status
IDENTITY CONSISTENT
Section 6

Annotations 3

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

ms_confirm
Purity at 99.93 % with identity confirmed on the same submission is the combination worth having. Either alone leaves a question the other answers.
buyer_sourced
Provenance and purity together are what make a figure like this usable. An independently purchased vial at 99.93 % is worth several supplier-selected ones.
coa_reader
Provenance and documentation are independent axes. A supplier-selected sample with a complete lot-specific certificate is stronger evidence than an independently purchased one with no paperwork at all.
Section 7

Related records

Same batch — lot JEEP-2412-M9286 n=9

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-019504JEEP-2412-M9286Janoshik2025-Q299.846.11Buyer-sourced0FAIL
AX-2025-019505JEEP-2412-M9286PeptideMeter2025-Q299.785.44107.4Buyer-sourced0FAIL
AX-2025-019506JEEP-2412-M9286Janoshik2025-Q299.936.19100.8Buyer-sourced0FAIL
AX-2025-019508JEEP-2412-M9286Janoshik2025-Q299.765.07Buyer-sourced0FAIL
AX-2025-019509JEEP-2412-M9286PeptideMeter2025-Q299.355.87Buyer-sourced0FAIL
AX-2025-019510JEEP-2412-M9286PeptideMeter2025-Q299.936.04Buyer-sourced0FAIL
AX-2025-019511JEEP-2412-M9286Janoshik2025-Q299.935.05Buyer-sourced1FAIL
AX-2025-019512JEEP-2412-M9286Medutest2025-Q299.935.62104.7Buyer-sourced1FAIL
Other recent 5-Amino-1MQ records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043050KPKP-2511-W5347Janoshik2026-Q299.354.16105.5Buyer-sourced0FAIL
AX-2026-043044KPKP-2511-W5347PeptideMeter2026-Q299.614.1590.9Buyer-sourced0FAIL
AX-2026-043052KPKP-2511-W5347Medutest2026-Q299.454.23105.5Buyer-sourced1FAIL
AX-2026-043045KPKP-2511-W5347Janoshik2026-Q299.474.08Buyer-sourced0FAIL
AX-2026-043043KPKP-2511-W5347Janoshik2026-Q299.584.16101.1Buyer-sourced0FAIL
AX-2026-042869GGPepsGGPE-2512-M2434Kestrel2026-Q299.554.65103.9Buyer-sourced0FAIL
AX-2026-042868GGPepsGGPE-2512-M2434PeptideMeter2026-Q299.324.3988.5Buyer-sourced1FAIL
AX-2026-043047KPKP-2511-W5347Janoshik2026-Q299.684.17104.0Supplier-supplied0FAIL
Other recent JEEP records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042177HexarelinJEEP-2608-Y9547Janoshik2026-Q399.903.42Buyer-sourced0PASS
AX-2026-042162SemaglutideJEEP-2607-X9091Janoshik2026-Q398.983.46Laboratory-retained1MARGINAL
AX-2026-042127TB-500JEEP-2602-V8614Medutest2026-Q399.683.55Buyer-sourced1FAIL
AX-2026-042123TB-500JEEP-2602-V8614PeptideMeter2026-Q399.933.80Buyer-sourced0PASS
AX-2026-042124TB-500JEEP-2602-V8614PeptideMeter2026-Q399.913.37104.9Buyer-sourced0PASS
AX-2026-042178HexarelinJEEP-2608-Y9547VendorInvestigate2026-Q399.684.03Buyer-sourced0PASS
AX-2026-042163SemaglutideJEEP-2607-X9091Nordanalyt2026-Q399.464.52Buyer-sourced1MARGINAL
AX-2026-042122TB-500JEEP-2602-V8614PeptideMeter2026-Q399.603.5897.0Buyer-sourced0PASS