AssayIndex

AX-2024-005246

MK-677 (Ibutamoren mesylate) · 1000 mg declared · WuXi TIDES (WuXi AppTec Testing Division) · lot WXT-2408-P3767

FAILIDENTITY CONSISTENT
Report ID
AX-2024-005246
Compound
MK-677 (Ibutamoren mesylate)
Compound class
Non-peptide adjuncts
Supplier
WXT — WuXi TIDES (WuXi AppTec Testing Division)
Batch / lot
WXT-2408-P3767
Declared label claim
1000mg
Laboratory
Medutest
Assay date
30 Oct 2024
Submitted
12 Nov 2024
Quarter
2024-Q4
Submitter
l.haddad
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the non-peptide adjuncts class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 25 min gradient, 214 nm99.29% area≥ 98.5PASS
Total impuritiesRP-HPLC, sum of reported peaks0.71% area≤ 1.5PASS
Largest single impurityRP-HPLC — sulfonamide hydrolysis product (+18 Da)0.39% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula624.2181DaNOT TESTED
Identity — observed monoisotopic massLC-MS, unit resolution (single quadrupole)624.2190DaNOT TESTED
Mass accuracyobserved vs theoretical+1.5ppm± 10PASS
Total peptide contentby difference from the gravimetric mass balance79.04%w/wNOT TESTED
Target-compound contenttotal peptide content × purity78.48%w/wNOT TESTED
Gross fill (as weighed)five-place balance, under nitrogen1142.93mg1000 mg declaredNOT TESTED
Recovered target peptidegross fill × target content896.971mg1000 mg claimNOT TESTED
Recovery against label claimrecovered ÷ claim89.7%90.0 – 110.0FAIL
Water contentKarl Fischer, coulometric, duplicate4.65%≤ 10.0PASS
Counter-ion (mesylate)anion-exchange ion chromatography16.11%≤ 12.0FAIL
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.20%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundOff-white lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration4.962.5 – 8.0PASS
Retention time (observed)RP-HPLC, 25 min gradient11.78min11.73 ± 0.30 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.460.860.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²72,353≥ 20,000PASS
Resolution to nearest impurityvs free base (des-mesylate, −96 Da)0.19no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

027665532829811063 MK-677 (Ibutamoren mesylate)11.78 min · 99.29 % 11.064.95 same trace · ×100 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 0481216202428 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 25 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 72,353, and skew follows the reported asymmetry factor of 0.86. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.39 % impurity against a 99.29 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1MK-677 (Ibutamoren mesylate) — main peak11.784,825,80299.29
2sulfonamide hydrolysis product (+18 Da)11.0618,9550.39+18.011
3free base (des-mesylate, −96 Da)11.817,7760.16-96.011
4spiroindane regioisomer12.153,4020.070.000
5residual DMF (process solvent)4.952,4300.05-551.000
6O-desmethyl metabolite analogue (−14 Da)11.351,9440.04-14.016
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 624.2181 Da, computed from C27H36N4O5S · CH4O3S. All ppm figures on this site are against monoisotopic values — see why that matters.

0255075100250325400475550625700 [M+1H]1+625.23[M+2H]2+313.12 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, unit-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 624.2190 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
2+313.1163313.11680.000556.2
1+625.2254625.22630.0009100.0
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

ComponentDetermination%w/w of cake
WaterKarl Fischer4.65
Counter-ion (mesylate)ion chromatography16.11
Residual solvent + inorganic residueestimated0.20
Total peptide contentby difference79.04
Total100.00 CLOSES

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.099.29divergence -0.10 pp vs batch median
Total impurities (% area)1.000.71
Largest single impurity (% area)not stated0.39
Water (%)not stated4.65
Counter-ion (%)9.016.11
Peptide content (%w/w)86.979.04
Endotoxin (EU/mg)not statednot determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → third-party forwarder (31 d) → laboratory (courier, cold pack, 4 d) → assay.
Assay date
30 Oct 2024
Submitted to the index
12 Nov 2024
Laboratory
Medutest, Ljubljana, Slovenia
Method basis
25 min gradient · unit-resolution MS
Verification status
IDENTITY CONSISTENT
Section 6

Annotations 4

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

quad_unit
Identity confirmed and purity at 99.29 %. The two answer different questions — what it is, and how much else is in it — and a record carrying both is the version worth citing.
coa_reader
Declared figure and measured figure on this lot agree within measurement repeatability. Whatever the rounding convention is doing, it is not moving the number away from the material.
round_numbers
The declared figure for WXT-2408-P3767 and the independent median differ by less than the inter-lab limits of agreement. That is the comparison that matters and the rounding does not change it.
desiccant_note
The packaging as received is part of the evidence on a retail purchase. Whether a desiccant was in the box is a fact about ordinary shipments, not about sample shipments.
Section 7

Related records

Same batch — lot WXT-2408-P3767 n=9

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-021003WXT-2408-P3767PeptideMeter2024-Q499.124.55Buyer-sourced1FAIL
AX-2024-005243WXT-2408-P3767Nordanalyt2024-Q499.114.9494.4Buyer-sourced1FAIL
AX-2024-005244WXT-2408-P3767Janoshik2024-Q498.704.57102.8Buyer-sourced2FAIL
AX-2024-005245WXT-2408-P3767Kestrel2024-Q498.734.8392.4Buyer-sourced1FAIL
AX-2024-005247WXT-2408-P3767Kestrel2024-Q499.094.42Buyer-sourced2FAIL
AX-2024-005248WXT-2408-P3767Janoshik2024-Q498.914.81105.1Buyer-sourced1FAIL
AX-2024-005249WXT-2408-P3767Janoshik2024-Q499.354.50104.3Buyer-sourced1FAIL
AX-2025-021004WXT-2408-P3767Janoshik2024-Q499.104.9291.6Supplier-supplied1FAIL
Other recent MK-677 (Ibutamoren mesylate) records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041633FGPFGP-2604-K8509PeptideMeter2026-Q299.814.9196.2Buyer-sourced0FAIL
AX-2026-041733TFSTFS-{CAT}-1096PeptideMeter2026-Q299.073.9395.1Laboratory-retained0FAIL
AX-2026-043468BCHBCH-2511-G5204Medutest2026-Q298.854.3096.5Buyer-sourced1FAIL
AX-2026-042647SWBSWB-2605-B7365Nordanalyt2026-Q299.282.8693.1Buyer-sourced0FAIL
AX-2026-041634FGPFGP-2604-K8509PeptideMeter2026-Q299.865.17Buyer-sourced0FAIL
AX-2026-043469BCHBCH-2511-G5204Medutest2026-Q298.514.86Buyer-sourced1FAIL
AX-2026-042648SWBSWB-2605-B7365Janoshik2026-Q299.932.6096.9Supplier-supplied0FAIL
AX-2026-041732TFSTFS-{CAT}-1096Janoshik2026-Q299.483.16106.4Buyer-sourced0FAIL
Other recent WXT records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043376SemaglutideWXT-2604-C3248Janoshik2026-Q397.084.22Buyer-sourced1MARGINAL
AX-2026-043429L-Glutathione (reduced)WXT-2605-B3833Nordanalyt2026-Q398.486.5896.9Supplier-supplied1FAIL
AX-2026-043347LeuprolideWXT-2604-K2596PeptideMeter2026-Q399.165.9993.6Buyer-sourced0PASS
AX-2026-043353LeuprolideWXT-2604-K2596Janoshik2026-Q399.194.9095.3Laboratory-retained0PASS
AX-2026-043345LeuprolideWXT-2604-K2596Janoshik2026-Q398.935.28Buyer-sourced0PASS
AX-2026-043424L-Glutathione (reduced)WXT-2605-B3833PeptideMeter2026-Q398.376.86Buyer-sourced0FAIL
AX-2026-043374SemaglutideWXT-2604-C3248Janoshik2026-Q397.003.56Buyer-sourced1MARGINAL
AX-2026-043377SemaglutideWXT-2604-C3248PeptideMeter2026-Q397.204.08Buyer-sourced1MARGINAL