AssayIndex

AX-2024-004690

MK-677 (Ibutamoren mesylate) · 250 mg declared · Hunan Aslsen Technology Co., Ltd. · lot HOMO-2401-J3421

FAILIDENTITY CONSISTENT
Report ID
AX-2024-004690
Compound
MK-677 (Ibutamoren mesylate)
Compound class
Non-peptide adjuncts
Supplier
Homopeptide — Hunan Aslsen Technology Co., Ltd.
Batch / lot
HOMO-2401-J3421
Declared label claim
250mg
Laboratory
Janoshik Analytical
Assay date
12 Apr 2024
Submitted
07 May 2024
Quarter
2024-Q2
Submitter
a.chowdhury
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the non-peptide adjuncts class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 30 min gradient, 214 nm99.77% area≥ 98.5PASS
Total impuritiesRP-HPLC, sum of reported peaks0.23% area≤ 1.5PASS
Largest single impurityRP-HPLC — residual DMF (process solvent)0.10% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula624.2181DaNOT TESTED
Identity — observed monoisotopic massLC-MS, high resolution (ESI-TOF/QTOF)624.2173DaNOT TESTED
Mass accuracyobserved vs theoretical-1.3ppm± 10PASS
Peptide contentnot ordered on this submissionnot determinedrequired to check label claimNOT TESTED
Water contentKarl Fischer, coulometric, duplicate4.40%≤ 10.0PASS
Counter-ion (mesylate)anion-exchange ion chromatography12.91%≤ 12.0FAIL
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.80%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite cake, partial shrinkage from vial wallwhite to off-white intact cakeFAIL
Reconstitution clarityreconstituted per submitter procedureFaint haze, clearing on standingclear, no visible particulatesFAIL
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration4.532.5 – 8.0PASS
Retention time (observed)RP-HPLC, 30 min gradient13.95min13.86 ± 0.30 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.000.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²60,145≥ 20,000PASS
Resolution to nearest impurityvs free base (des-mesylate, −96 Da)0.17no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

02031406260938124 MK-677 (Ibutamoren mesylate)13.95 min · 99.77 % 5.7513.09 same trace · ×200 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 05101520253035 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 30 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 60,145, and skew follows the reported asymmetry factor of 1.00. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.10 % impurity against a 99.77 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1MK-677 (Ibutamoren mesylate) — main peak13.954,849,13199.77
2residual DMF (process solvent)5.754,8600.10-551.000
3sulfonamide hydrolysis product (+18 Da)13.094,3740.09+18.011
4free base (des-mesylate, −96 Da)13.991,9440.04-96.011
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 624.2181 Da, computed from C27H36N4O5S · CH4O3S. All ppm figures on this site are against monoisotopic values — see why that matters.

0255075100250325400475550625700 [M+1H]1+625.22[M+2H]2+313.12 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, high-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 624.2173 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
2+313.1163313.1159-0.000450.1
1+625.2254625.2246-0.0008100.0
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.9099.77divergence +0.05 pp vs batch median
Total impurities (% area)0.100.23
Largest single impurity (% area)0.030.10
Water (%)4.24.40
Counter-ion (%)7.012.91
Peptide content (%w/w)88.2not determined
Endotoxin (EU/mg)0.19not determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → submitter (−20 °C, 17 d) → laboratory (courier, dry ice, 7 d) → assay.
Assay date
12 Apr 2024
Submitted to the index
07 May 2024
Laboratory
Janoshik Analytical, Ostrava, Czechia
Method basis
30 min gradient · high-resolution MS
Verification status
IDENTITY CONSISTENT
Section 6

Annotations 3

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

c18_2p6
Column chemistry flatters or punishes a figure like this. A core-shell column at this gradient resolves the close-eluting family that a fully porous 5 µm bed merges, so 99.77 % here is a harder number than the same figure from a coarser column.
fill_homogeneity
A high figure on one vial is a statement about one vial. The within-lot spread on the batch rollup is what tells you whether the bulk was well mixed, and it is the rarer and more useful number.
ppm_error
Mass, retention and impurity profile all agree on this record. Three independent constraints pointing the same way is the strongest identity evidence the index publishes.
Section 7

Related records

Same batch — lot HOMO-2401-J3421 n=6

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2024-004687HOMO-2401-J3421PeptideMeter2024-Q299.763.8390.5Buyer-sourced0FAIL
AX-2024-004688HOMO-2401-J3421VendorInvestigate2024-Q299.274.4695.1Buyer-sourced0FAIL
AX-2024-004689HOMO-2401-J3421PeptideMeter2024-Q299.934.28105.9Buyer-sourced0FAIL
AX-2024-004691HOMO-2401-J3421PeptideMeter2024-Q299.934.56Buyer-sourced0FAIL
AX-2024-004692HOMO-2401-J3421Kestrel2024-Q299.934.73Buyer-sourced1FAIL
Other recent MK-677 (Ibutamoren mesylate) records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041633FGPFGP-2604-K8509PeptideMeter2026-Q299.814.9196.2Buyer-sourced0FAIL
AX-2026-041733TFSTFS-{CAT}-1096PeptideMeter2026-Q299.073.9395.1Laboratory-retained0FAIL
AX-2026-043468BCHBCH-2511-G5204Medutest2026-Q298.854.3096.5Buyer-sourced1FAIL
AX-2026-042647SWBSWB-2605-B7365Nordanalyt2026-Q299.282.8693.1Buyer-sourced0FAIL
AX-2026-041634FGPFGP-2604-K8509PeptideMeter2026-Q299.865.17Buyer-sourced0FAIL
AX-2026-043469BCHBCH-2511-G5204Medutest2026-Q298.514.86Buyer-sourced1FAIL
AX-2026-042648SWBSWB-2605-B7365Janoshik2026-Q299.932.6096.9Supplier-supplied0FAIL
AX-2026-041732TFSTFS-{CAT}-1096Janoshik2026-Q299.483.16106.4Buyer-sourced0FAIL
Other recent Homopeptide records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042437RetatrutideHOMO-2605-V4718Nordanalyt2026-Q398.683.67102.8Buyer-sourced0PASS
AX-2026-042424SemaglutideHOMO-2604-X3806PeptideMeter2026-Q398.854.8792.0Buyer-sourced0PASS
AX-2026-042503IGF-1 LR3HOMO-2607-P5131Janoshik2026-Q399.365.99Buyer-sourced0PASS
AX-2026-042492SS-31 (Elamipretide)HOMO-2604-D5484Medutest2026-Q399.932.40Buyer-sourced0PASS
AX-2026-042491SS-31 (Elamipretide)HOMO-2604-D5484Kestrel2026-Q399.933.24Supplier-supplied0PASS
AX-2026-042473LL-37HOMO-2602-G5165Janoshik2026-Q399.015.00Buyer-sourced0PASS
AX-2026-042441RetatrutideHOMO-2605-V4718Medutest2026-Q398.934.22Buyer-sourced0PASS
AX-2026-042474LL-37HOMO-2602-G5165Janoshik2026-Q399.185.44Buyer-sourced0PASS