AssayIndex
Cross-section

Kisspeptin-10 by laboratory

The same compound measured by different laboratories on different gradients. Where the medians differ, the question is whether the material differed or the method did — and for Kisspeptin-10, with a class minimum gradient of 22 min, the method is a live explanation.

76 recordsmedian 99.28 %spec 98.5 %
LaboratoryReportsGradientMS resolutionMedian purity %Published bias (pp)Bias-adjustedMethod suitability
Janoshik3630minHigh99.20+0.0099.20ADEQUATE
Medutest1225minUnit99.09+0.0899.01ADEQUATE
PeptideMeter928minHigh99.28-0.0599.33ADEQUATE
Nordanalyt835minHigh99.45+0.0299.43ADEQUATE
VendorInvestigate7 n=732minHigh99.64-0.1199.75ADEQUATE
Kestrel4 n=415minUnit99.56+0.2499.33BELOW CLASS MINIMUM
98.298.598.899.299.599.8100.1JanoshikJanoshik: Q1 98.77, median 99.20, Q3 99.54, n=36n=36PeptideMeterPeptideMeter: Q1 98.92, median 99.28, Q3 99.49, n=9n=9MedutestMedutest: Q1 98.95, median 99.09, Q3 99.93, n=12n=12VendorInvestigateVendorInvestigate: Q1 99.33, median 99.64, Q3 99.86, n=7n=7NordanalytNordanalyt: Q1 98.89, median 99.45, Q3 99.51, n=8n=8KestrelKestrel: Q1 99.53, median 99.56, Q3 99.68, n=4outlier 99.93n=4 Purity (% area)
Figure. Kisspeptin-10 purity by contributing laboratory. Any offset between rows has two possible sources — a real difference in the material each laboratory happened to receive, and the laboratory's own bias — and this figure cannot separate them. The paired analysis that can is on inter-lab agreement.