AssayIndex

AX-2026-042976

MK-677 (Ibutamoren mesylate) · 1000 mg declared · Xi'an Mokemei Biotechnology Co., Ltd. · lot MKM-2509-T3949

FAILIDENTITY CONSISTENT
Report ID
AX-2026-042976
Compound
MK-677 (Ibutamoren mesylate)
Compound class
Non-peptide adjuncts
Supplier
MKM — Xi'an Mokemei Biotechnology Co., Ltd.
Batch / lot
MKM-2509-T3949
Declared label claim
1000mg
Laboratory
PeptideMeter
Assay date
29 Jan 2026
Submitted
30 Jan 2026
Quarter
2026-Q1
Submitter
ru.villalobos
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the non-peptide adjuncts class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 28 min gradient, 214 nm99.40% area≥ 98.5PASS
Total impuritiesRP-HPLC, sum of reported peaks0.60% area≤ 1.5PASS
Largest single impurityRP-HPLC — sulfonamide hydrolysis product (+18 Da)0.41% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula624.2181DaNOT TESTED
Identity — observed monoisotopic massLC-MS, high resolution (ESI-TOF/QTOF)624.2181DaNOT TESTED
Mass accuracyobserved vs theoretical0.0ppm± 10PASS
Peptide contentnot ordered on this submissionnot determinedrequired to check label claimNOT TESTED
Water contentKarl Fischer, coulometric, duplicate3.48%≤ 10.0PASS
Counter-ion (mesylate)anion-exchange ion chromatography14.82%≤ 12.0FAIL
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.76%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite to pale-yellow cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear after 90 s gentle swirling, no particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration5.012.5 – 8.0PASS
Retention time (observed)RP-HPLC, 28 min gradient13.00min13.01 ± 0.30 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.460.900.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²62,726≥ 20,000PASS
Resolution to nearest impurityvs free base (des-mesylate, −96 Da)0.18no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

02335467070059340 MK-677 (Ibutamoren mesylate)13.00 min · 99.40 % 12.205.35 same trace · ×100 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 051015202530 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 28 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 62,726, and skew follows the reported asymmetry factor of 0.90. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.41 % impurity against a 99.40 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1MK-677 (Ibutamoren mesylate) — main peak13.004,831,14899.40
2sulfonamide hydrolysis product (+18 Da)12.2019,9270.41+18.011
3free base (des-mesylate, −96 Da)13.044,3740.09-96.011
4spiroindane regioisomer13.412,4300.050.000
5O-desmethyl metabolite analogue (−14 Da)12.511,4580.03-14.016
6residual DMF (process solvent)5.359720.02-551.000
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 624.2181 Da, computed from C27H36N4O5S · CH4O3S. All ppm figures on this site are against monoisotopic values — see why that matters.

0255075100250325400475550625700 [M+1H]1+625.23[M+2H]2+313.12 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, high-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 624.2181 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
2+313.1163313.1163-0.000054.9
1+625.2254625.22540.0000100.0
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)98.8099.40divergence -0.53 pp vs batch median
Total impurities (% area)1.200.60
Largest single impurity (% area)0.730.41
Water (%)3.13.48
Counter-ion (%)not stated14.82
Peptide content (%w/w)92.1not determined
Endotoxin (EU/mg)1.92not determined
Method stated on certificateNOno method section — the result cannot be reconciled against any other
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → submitter (ambient, 8 d) → laboratory (courier, cold pack, 10 d) → assay.
Assay date
29 Jan 2026
Submitted to the index
30 Jan 2026
Laboratory
PeptideMeter, Tallinn, Estonia
Method basis
28 min gradient · high-resolution MS
Verification status
IDENTITY CONSISTENT
Section 6

Annotations 3

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

wide_iqr
A single result at 99.40 % is one draw. What makes a supplier's process legible is the spread across its lots, and that is on the scorecard rather than here. This record is one good point in a distribution worth reading whole.
multiple_compare
Restricting every supplier comparison to buyer-sourced records is the sensitivity analysis the scorecards publish. On the current dataset it changes no ordering that was not already inside measurement noise.
c18_2p6
Core-shell packing at 2.6 µm gains roughly 40 % in resolution over a 5 µm fully porous bed at the same length and pressure. On a pair this close, that is the difference between two peaks and one.
Section 7

Related records

Same batch — lot MKM-2509-T3949 n=6

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042972MKM-2509-T3949Nordanalyt2026-Q199.342.69Buyer-sourced0FAIL
AX-2026-042973MKM-2509-T3949Medutest2026-Q199.603.56Supplier-supplied0FAIL
AX-2026-042974MKM-2509-T3949Medutest2026-Q199.314.15Buyer-sourced1FAIL
AX-2026-042975MKM-2509-T3949PeptideMeter2026-Q199.233.69Laboratory-retained0FAIL
AX-2026-042977MKM-2509-T3949Janoshik2026-Q198.983.5393.6Buyer-sourced0FAIL
Other recent MK-677 (Ibutamoren mesylate) records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041633FGPFGP-2604-K8509PeptideMeter2026-Q299.814.9196.2Buyer-sourced0FAIL
AX-2026-041733TFSTFS-{CAT}-1096PeptideMeter2026-Q299.073.9395.1Laboratory-retained0FAIL
AX-2026-043468BCHBCH-2511-G5204Medutest2026-Q298.854.3096.5Buyer-sourced1FAIL
AX-2026-042647SWBSWB-2605-B7365Nordanalyt2026-Q299.282.8693.1Buyer-sourced0FAIL
AX-2026-041634FGPFGP-2604-K8509PeptideMeter2026-Q299.865.17Buyer-sourced0FAIL
AX-2026-043469BCHBCH-2511-G5204Medutest2026-Q298.514.86Buyer-sourced1FAIL
AX-2026-042648SWBSWB-2605-B7365Janoshik2026-Q299.932.6096.9Supplier-supplied0FAIL
AX-2026-041732TFSTFS-{CAT}-1096Janoshik2026-Q299.483.16106.4Buyer-sourced0FAIL
Other recent MKM records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042942CJC-1295 (no DAC)MKM-2603-V3346Janoshik2026-Q399.523.43Supplier-supplied0PASS
AX-2026-043019AdipotideMKM-2606-K5012Janoshik2026-Q397.615.77105.1Buyer-sourced0PASS
AX-2026-042939CJC-1295 (no DAC)MKM-2603-V3346PeptideMeter2026-Q399.443.39Buyer-sourced0PASS
AX-2026-043020AdipotideMKM-2606-K5012Medutest2026-Q397.735.74Buyer-sourced0PASS
AX-2026-043022AdipotideMKM-2606-K5012Kestrel2026-Q397.696.33106.9Buyer-sourced0PASS
AX-2026-043023AdipotideMKM-2606-K5012Medutest2026-Q397.485.56103.7Supplier-supplied0PASS
AX-2026-042945CJC-1295 (no DAC)MKM-2603-V3346PeptideMeter2026-Q399.393.54Laboratory-retained0PASS
AX-2026-042938CJC-1295 (no DAC)MKM-2603-V3346Nordanalyt2026-Q399.473.6795.0Buyer-sourced0PASS