AssayIndex

AX-2026-042090

MOTS-c · 10 mg declared · Shenzhen Hybio Pharmaceutical Co., Ltd. · lot HYB-2606-D7858

FAILIDENTITY CONSISTENT
Report ID
AX-2026-042090
Compound
MOTS-c
Compound class
Metabolic and mitochondrial peptides
Supplier
HYB — Shenzhen Hybio Pharmaceutical Co., Ltd.
Batch / lot
HYB-2606-D7858
Declared label claim
10mg
Laboratory
Janoshik Analytical
Assay date
11 Sep 2026
Submitted
30 Sep 2026
Quarter
2026-Q3
Submitter
a.halonen
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the metabolic and mitochondrial peptides class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 30 min gradient, 214 nm99.57% area≥ 98.0PASS
Total impuritiesRP-HPLC, sum of reported peaks0.43% area≤ 2.0PASS
Largest single impurityRP-HPLC — des-Met1 (−131 Da)0.20% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula2173.0918DaNOT TESTED
Identity — observed monoisotopic massLC-MS, high resolution (ESI-TOF/QTOF)2173.1518DaNOT TESTED
Mass accuracyobserved vs theoretical+27.6ppm± 15FAIL
Peptide contentnot ordered on this submissionnot determinedrequired to check label claimNOT TESTED
Water contentKarl Fischer, coulometric, duplicate2.36%≤ 9.0PASS
Counter-ion (acetate)anion-exchange ion chromatography3.54%≤ 12.0PASS
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.89%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration4.882.5 – 8.0PASS
Retention time (observed)RP-HPLC, 30 min gradient10.43min10.42 ± 0.30 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.160.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²41,088≥ 20,000PASS
Resolution to nearest impurityvs des-Met1 (−131 Da)1.04no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

02074414862228296 MOTS-c10.43 min · 99.57 % 10.65 same trace · ×200 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 05101520253035 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 30 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 41,088, and skew follows the reported asymmetry factor of 1.16. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.20 % impurity against a 99.57 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1MOTS-c — main peak10.434,839,41199.57
2des-Met1 (−131 Da)10.659,7210.20-131.040
3Met1 sulfoxide (+16 Da)10.055,3460.11+15.995
4bis-sulfoxide (+32 Da)9.772,9160.06+31.990
5deamidated (+1 Da)10.132,9160.06+0.984
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 2173.0918 Da, computed from C101H152N28O22S2. All ppm figures on this site are against monoisotopic values — see why that matters.

02550751003256751025137517252075 [M+2H]2+1087.58[M+1H]1+2174.16[M+3H]3+725.39 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, high-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 2173.1518 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
4+544.2802544.29520.01507.9
3+725.3712725.39120.020051.4
2+1087.55321087.58320.0300100.0
1+2174.09912174.15910.060052.6
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.3599.57divergence -0.19 pp vs batch median
Total impurities (% area)0.650.43
Largest single impurity (% area)0.480.20
Water (%)not stated2.36
Counter-ion (%)not stated3.54
Peptide content (%w/w)91.7not determined
Endotoxin (EU/mg)1.59not determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → submitter (−20 °C, 27 d) → laboratory (courier, dry ice, 11 d) → assay.
Assay date
11 Sep 2026
Submitted to the index
30 Sep 2026
Laboratory
Janoshik Analytical, Ostrava, Czechia
Method basis
30 min gradient · high-resolution MS
Verification status
IDENTITY CONSISTENT
Section 6

Annotations 4

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

isotope_cluster
At this mass the monoisotopic peak may not be the most intense peak in the cluster. Picking the apex instead of the monoisotopic peak produces a systematic positive error of roughly the size flagged here.
esi_tof
Ion suppression from a co-eluting counter-ion at 3.54 % acetate can shift an apparent mass in a time-of-flight measurement. Desalting the injection before the mass determination removes the possibility.
schema_v2
The dataset stores signed ppm error, so the direction survives into the CSV. Anyone aggregating absolute values should take the modulus explicitly rather than relying on the field.
ppm_error
A single excursion of this size against a clean run of prior results on the same instrument is a calibration event with a date on it. The laboratory's own sequence log would place it; the index does not hold one.
Section 7

Related records

Same batch — lot HYB-2606-D7858 n=11

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042080HYB-2606-D7858VendorInvestigate2026-Q398.292.1095.6Laboratory-retained0PASS
AX-2026-042081HYB-2606-D7858Nordanalyt2026-Q399.683.3196.5Laboratory-retained0PASS
AX-2026-042082HYB-2606-D7858Janoshik2026-Q399.862.13Buyer-sourced0PASS
AX-2026-042083HYB-2606-D7858Medutest2026-Q399.932.02Buyer-sourced0PASS
AX-2026-042084HYB-2606-D7858Janoshik2026-Q399.282.79107.3Buyer-sourced0PASS
AX-2026-042085HYB-2606-D7858Janoshik2026-Q399.512.31Buyer-sourced0PASS
AX-2026-042086HYB-2606-D7858Janoshik2026-Q399.933.02Buyer-sourced1MARGINAL
AX-2026-042087HYB-2606-D7858Janoshik2026-Q399.543.05Buyer-sourced0PASS
AX-2026-042088HYB-2606-D7858PeptideMeter2026-Q399.222.21Buyer-sourced0PASS
AX-2026-042089HYB-2606-D7858Medutest2026-Q399.382.65Buyer-sourced0PASS
Other recent MOTS-c records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042083HYBHYB-2606-D7858Medutest2026-Q399.932.02Buyer-sourced0PASS
AX-2026-042084HYBHYB-2606-D7858Janoshik2026-Q399.282.79107.3Buyer-sourced0PASS
AX-2026-042087HYBHYB-2606-D7858Janoshik2026-Q399.543.05Buyer-sourced0PASS
AX-2026-042085HYBHYB-2606-D7858Janoshik2026-Q399.512.31Buyer-sourced0PASS
AX-2026-042088HYBHYB-2606-D7858PeptideMeter2026-Q399.222.21Buyer-sourced0PASS
AX-2026-042086HYBHYB-2606-D7858Janoshik2026-Q399.933.02Buyer-sourced1MARGINAL
AX-2026-042081HYBHYB-2606-D7858Nordanalyt2026-Q399.683.3196.5Laboratory-retained0PASS
AX-2026-042089HYBHYB-2606-D7858Medutest2026-Q399.382.65Buyer-sourced0PASS
Other recent HYB records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042083MOTS-cHYB-2606-D7858Medutest2026-Q399.932.02Buyer-sourced0PASS
AX-2026-042084MOTS-cHYB-2606-D7858Janoshik2026-Q399.282.79107.3Buyer-sourced0PASS
AX-2026-042087MOTS-cHYB-2606-D7858Janoshik2026-Q399.543.05Buyer-sourced0PASS
AX-2026-042085MOTS-cHYB-2606-D7858Janoshik2026-Q399.512.31Buyer-sourced0PASS
AX-2026-042088MOTS-cHYB-2606-D7858PeptideMeter2026-Q399.222.21Buyer-sourced0PASS
AX-2026-042086MOTS-cHYB-2606-D7858Janoshik2026-Q399.933.02Buyer-sourced1MARGINAL
AX-2026-042091CJC-1295 with DACHYB-2608-E7391Janoshik2026-Q399.385.53Buyer-sourced0PASS
AX-2026-042081MOTS-cHYB-2606-D7858Nordanalyt2026-Q399.683.3196.5Laboratory-retained0PASS