AssayIndex

AX-2025-021066

Tirzepatide · 60 mg declared · Bachem Holding (Suzhou) Co., Ltd. · lot BCH-2501-D4197

MARGINALPURITY ONLY
Report ID
AX-2025-021066
Compound
Tirzepatide
Compound class
Incretin analogues and co-agonists
Supplier
BCH — Bachem Holding (Suzhou) Co., Ltd.
Batch / lot
BCH-2501-D4197
Declared label claim
60mg
Laboratory
Janoshik Analytical
Assay date
23 Apr 2025
Submitted
29 Apr 2025
Quarter
2025-Q2
Submitter
ju.iyer
Sample provenance
Supplier-supplied
Section 1

Results

Measured against the index acceptance specification for the incretin analogues and co-agonists class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 30 min gradient, 214 nm97.97% area≥ 97.0PASS
Total impuritiesRP-HPLC, sum of reported peaks2.03% area≤ 3.0PASS
Largest single impurityRP-HPLC — trifluoroacetyl adduct (+96 Da)1.40% area≤ 1.00FAIL
Identitynot ordered on this submissionnot determinedrequired for VERIFIED statusNOT TESTED
Total peptide contentby difference from the gravimetric mass balance85.86%w/wNOT TESTED
Target-compound contenttotal peptide content × purity84.12%w/wNOT TESTED
Gross fill (as weighed)five-place balance, under nitrogen65.94mg60 mg declaredNOT TESTED
Recovered target peptidegross fill × target content55.469mg60 mg claimNOT TESTED
Recovery against label claimrecovered ÷ claim92.4%90.0 – 110.0PASS
Water contentKarl Fischer, coulometric, duplicate4.12%≤ 8.0PASS
Counter-ion (TFA)anion-exchange ion chromatography9.51%≤ 12.0PASS
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.51%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite to pale-yellow cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration3.082.5 – 8.0PASS
Retention time (observed)RP-HPLC, 30 min gradient19.84min19.86 ± 0.45 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.460.990.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²64,499≥ 20,000PASS
Resolution to nearest impurityvs [D-Aib13]-diastereomer0.59no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

01459291943785837 Tirzepatide19.84 min · 97.97 % 20.7723.82 same trace · ×50 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 05101520253035 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 30 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 64,499, and skew follows the reported asymmetry factor of 0.99. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 1.40 % impurity against a 97.97 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1Tirzepatide — main peak19.844,761,64697.97
2trifluoroacetyl adduct (+96 Da)20.7768,0441.40+95.982
3[D-Aib13]-diastereomer19.6519,9270.410.000
4C20 diacid mono-amide21.466,8040.14+0.984
5Met(O) sulfoxide (+16 Da)19.102,4300.05+15.995
6des-Gly deletion (−57 Da)19.239720.02-57.021
7tirzepatide dimer23.824860.01+4810.410
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

ComponentDetermination%w/w of cake
WaterKarl Fischer4.12
Counter-ion (TFA)ion chromatography9.51
Residual solvent + inorganic residueestimated0.51
Total peptide contentby difference85.86
Total100.00 CLOSES

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)97.3297.97divergence +0.07 pp vs batch median
Total impurities (% area)2.682.03
Largest single impurity (% area)not stated1.40
Water (%)2.84.12
Counter-ion (%)not stated9.51
Peptide content (%w/w)not stated85.86
Endotoxin (EU/mg)not statednot determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Supplier-supplied
Evidentiary weight
Weaker evidence. Read with the caveat below.
Chain of custody
Supplier despatch → laboratory direct (courier, cold pack, 2 d) → assay. Submitter did not handle the vial.
Assay date
23 Apr 2025
Submitted to the index
29 Apr 2025
Laboratory
Janoshik Analytical, Ostrava, Czechia
Method basis
30 min gradient · high-resolution MS
Verification status
PURITY ONLY
Section 6

Annotations 3

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

sample_vs_retail
The result is published in full and weighted the same as any other in the raw dataset. Down-weighting happens in the sensitivity analyses, transparently, rather than silently at intake.
valley_drop
The index's position is that the integration convention must be stated, not that any particular convention must be used. Both are defensible; only one can be reported and it should be named.
units_pedant
Percent by weight of the cake throughout, stated once and applied consistently. Mixing bases across the four slots is the commonest way a balance fails to close.
Section 7

Related records

Same batch — lot BCH-2501-D4197 n=11

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-021056BCH-2501-D4197VendorInvestigate2025-Q296.884.95Buyer-sourced0FAIL
AX-2025-021057BCH-2501-D4197PeptideMeter2025-Q297.354.72Buyer-sourced1FAIL
AX-2025-021058BCH-2501-D4197Nordanalyt2025-Q297.254.12Buyer-sourced0PASS
AX-2025-021059BCH-2501-D4197Janoshik2025-Q298.174.88Supplier-supplied1MARGINAL
AX-2025-021060BCH-2501-D4197Janoshik2025-Q296.854.3795.3Buyer-sourced0FAIL
AX-2025-021061BCH-2501-D4197Janoshik2025-Q297.004.10101.2Buyer-sourced0PASS
AX-2025-021062BCH-2501-D4197Medutest2025-Q297.494.70Supplier-supplied2FAIL
AX-2025-021063BCH-2501-D4197Medutest2025-Q296.844.83Buyer-sourced0FAIL
AX-2025-021064BCH-2501-D4197PeptideMeter2025-Q297.504.57Buyer-sourced0PASS
AX-2025-021065BCH-2501-D4197PeptideMeter2025-Q297.114.05101.4Buyer-sourced0PASS
Other recent Tirzepatide records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043288CPCCPC-2607-L1516Janoshik2026-Q396.895.11101.1Laboratory-retained0FAIL
AX-2026-041610FGPFGP-2603-L7753Janoshik2026-Q398.812.45101.0Buyer-sourced0PASS
AX-2026-041974AMBAMB-2603-C5112Nordanalyt2026-Q398.203.41Buyer-sourced0PASS
AX-2026-041975AMBAMB-2603-C5112Medutest2026-Q397.883.45106.9Laboratory-retained0PASS
AX-2026-041609FGPFGP-2603-L7753Janoshik2026-Q398.522.0098.0Buyer-sourced0PASS
AX-2026-041978AMBAMB-2603-C5112Janoshik2026-Q397.943.57103.0Buyer-sourced0PASS
AX-2026-041982AMBAMB-2603-C5112Janoshik2026-Q397.604.46Buyer-sourced0PASS
AX-2026-043286CPCCPC-2607-L1516Kestrel2026-Q398.204.56Buyer-sourced0PASS
Other recent BCH records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043445BPC-157BCH-2603-G4350Nordanalyt2026-Q398.424.8793.6Buyer-sourced1MARGINAL
AX-2026-043440BPC-157BCH-2603-G4350VendorInvestigate2026-Q398.614.11Buyer-sourced1MARGINAL
AX-2026-043442BPC-157BCH-2603-G4350Janoshik2026-Q398.654.78Buyer-sourced1MARGINAL
AX-2026-043471CJC-1295 with DACBCH-2607-H5235Janoshik2026-Q397.465.48Buyer-sourced1FAIL
AX-2026-043477CJC-1295 with DACBCH-2607-H5235VendorInvestigate2026-Q397.625.3299.6Buyer-sourced1MARGINAL
AX-2026-043449BPC-157BCH-2603-G4350Kestrel2026-Q399.744.9291.3Supplier-supplied2MARGINAL
AX-2026-043448BPC-157BCH-2603-G4350Janoshik2026-Q398.554.69106.9Buyer-sourced1MARGINAL
AX-2026-043470CJC-1295 with DACBCH-2607-H5235Janoshik2026-Q397.766.1199.3Supplier-supplied1MARGINAL