AssayIndex

AX-2025-020919

Survodutide · 15 mg declared · WuXi TIDES (WuXi AppTec Testing Division) · lot WXT-2501-X2463

MARGINALPURITY ONLY
Report ID
AX-2025-020919
Compound
Survodutide
Compound class
Incretin analogues and co-agonists
Supplier
WXT — WuXi TIDES (WuXi AppTec Testing Division)
Batch / lot
WXT-2501-X2463
Declared label claim
15mg
Laboratory
Janoshik Analytical
Assay date
02 May 2025
Submitted
26 May 2025
Quarter
2025-Q2
Submitter
s.nilsen
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the incretin analogues and co-agonists class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 30 min gradient, 214 nm97.79% area≥ 96.5PASS
Total impuritiesRP-HPLC, sum of reported peaks2.21% area≤ 3.5PASS
Largest single impurityRP-HPLC — [D-Ser2]-diastereomer1.53% area≤ 1.00FAIL
Identitynot ordered on this submissionnot determinedrequired for VERIFIED statusNOT TESTED
Total peptide contentby difference from the gravimetric mass balance86.51%w/wNOT TESTED
Target-compound contenttotal peptide content × purity84.60%w/wNOT TESTED
Gross fill (as weighed)five-place balance, under nitrogen16.66mg15 mg declaredNOT TESTED
Recovered target peptidegross fill × target content14.094mg15 mg claimNOT TESTED
Recovery against label claimrecovered ÷ claim94.0%90.0 – 110.0PASS
Water contentKarl Fischer, coulometric, duplicate3.88%≤ 8.0PASS
Counter-ion (TFA)anion-exchange ion chromatography8.79%≤ 12.0PASS
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.82%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration3.332.5 – 8.0PASS
Retention time (observed)RP-HPLC, 30 min gradient20.04min20.14 ± 0.50 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.460.860.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²78,012≥ 20,000PASS
Resolution to nearest impurityvs [D-Ser2]-diastereomer0.88no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

01661332149826643 Survodutide20.04 min · 97.79 % 19.7824.0921.48 same trace · ×20 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 05101520253035 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 30 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 78,012, and skew follows the reported asymmetry factor of 0.86. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 1.53 % impurity against a 97.79 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1Survodutide — main peak20.044,752,89797.79
2[D-Ser2]-diastereomer19.7874,3631.530.000
3aspartimide (−18 Da)20.6621,8710.45-18.011
4des-γGlu linker (−129 Da)19.095,8320.12-129.043
5survodutide dimer24.092,4300.05+4764.512
6truncated (2-39)18.681,9440.04-137.059
7C18 diacid mono-ester21.489720.02+14.016
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

ComponentDetermination%w/w of cake
WaterKarl Fischer3.88
Counter-ion (TFA)ion chromatography8.79
Residual solvent + inorganic residueestimated0.82
Total peptide contentby difference86.51
Total100.00 CLOSES

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)97.6497.79divergence -0.23 pp vs batch median
Total impurities (% area)1.402.21
Largest single impurity (% area)2.361.53
Water (%)3.33.88
Counter-ion (%)9.28.79
Peptide content (%w/w)86.986.51
Endotoxin (EU/mg)not statednot determined
Method stated on certificateNOno method section — the result cannot be reconciled against any other
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → submitter (2–8 °C, 29 d) → laboratory (courier, ambient, 12 d) → assay.
Assay date
02 May 2025
Submitted to the index
26 May 2025
Laboratory
Janoshik Analytical, Ostrava, Czechia
Method basis
30 min gradient · high-resolution MS
Verification status
PURITY ONLY
Section 6

Annotations 3

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

fill_homogeneity
One retail vial is one draw from a fill. Two or three from the same lot would separate fill variation from lot quality, and that is the cheapest useful experiment in this whole field.
label_claim
A retail vial is also a test of the label. Declared claim 15 mg against what the gravimetry recovers is a question only a purchased vial can answer honestly.
gradient_25
Resolution scales with the square root of plate count and linearly with selectivity. Shallowing the gradient changes selectivity, which is the more effective of the two levers on a close pair.
Section 7

Related records

Same batch — lot WXT-2501-X2463 n=10

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-020910WXT-2501-X2463Janoshik2025-Q297.854.32Buyer-sourced2MARGINAL
AX-2025-020911WXT-2501-X2463Medutest2025-Q298.043.7790.7Buyer-sourced2MARGINAL
AX-2025-020912WXT-2501-X2463Janoshik2025-Q297.894.15Buyer-sourced2MARGINAL
AX-2025-020913WXT-2501-X2463PeptideMeter2025-Q298.514.13Buyer-sourced2MARGINAL
AX-2025-020914WXT-2501-X2463PeptideMeter2025-Q297.954.2693.0Buyer-sourced2MARGINAL
AX-2025-020915WXT-2501-X2463Janoshik2025-Q297.743.7993.3Buyer-sourced2MARGINAL
AX-2025-020916WXT-2501-X2463Janoshik2025-Q297.794.51Buyer-sourced2MARGINAL
AX-2025-020917WXT-2501-X2463Nordanalyt2025-Q298.323.8398.1Supplier-supplied2MARGINAL
AX-2025-020918WXT-2501-X2463Medutest2025-Q297.664.1894.7Supplier-supplied3MARGINAL
Other recent Survodutide records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041831GSPGSP-2603-E3156Kestrel2026-Q399.915.5093.2Buyer-sourced0PASS
AX-2026-042706ERPERP-2605-E9865PeptideMeter2026-Q398.385.33103.5Buyer-sourced0PASS
AX-2026-041836GSPGSP-2603-E3156Janoshik2026-Q398.655.3490.3Buyer-sourced0PASS
AX-2026-041837GSPGSP-2603-E3156Janoshik2026-Q398.335.37Buyer-sourced0PASS
AX-2026-041833GSPGSP-2603-E3156Janoshik2026-Q398.084.9199.3Buyer-sourced0PASS
AX-2026-041832GSPGSP-2603-E3156VendorInvestigate2026-Q398.015.1499.5Buyer-sourced0PASS
AX-2026-041835GSPGSP-2603-E3156Nordanalyt2026-Q398.345.7489.0Buyer-sourced1MARGINAL
AX-2026-041834GSPGSP-2603-E3156VendorInvestigate2026-Q397.925.95Buyer-sourced0PASS
Other recent WXT records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043376SemaglutideWXT-2604-C3248Janoshik2026-Q397.084.22Buyer-sourced1MARGINAL
AX-2026-043429L-Glutathione (reduced)WXT-2605-B3833Nordanalyt2026-Q398.486.5896.9Supplier-supplied1FAIL
AX-2026-043347LeuprolideWXT-2604-K2596PeptideMeter2026-Q399.165.9993.6Buyer-sourced0PASS
AX-2026-043353LeuprolideWXT-2604-K2596Janoshik2026-Q399.194.9095.3Laboratory-retained0PASS
AX-2026-043345LeuprolideWXT-2604-K2596Janoshik2026-Q398.935.28Buyer-sourced0PASS
AX-2026-043424L-Glutathione (reduced)WXT-2605-B3833PeptideMeter2026-Q398.376.86Buyer-sourced0FAIL
AX-2026-043374SemaglutideWXT-2604-C3248Janoshik2026-Q397.003.56Buyer-sourced1MARGINAL
AX-2026-043377SemaglutideWXT-2604-C3248PeptideMeter2026-Q397.204.08Buyer-sourced1MARGINAL