AssayIndex

AX-2024-004604

5-Amino-1MQ · 50 mg declared · Tianjin Finder Chemical Co., Ltd. · lot TFC-2406-A1769

FAILVERIFIED
Report ID
AX-2024-004604
Compound
5-Amino-1MQ
Compound class
Non-peptide adjuncts
Supplier
TFC — Tianjin Finder Chemical Co., Ltd.
Batch / lot
TFC-2406-A1769
Declared label claim
50mg
Laboratory
Janoshik Analytical
Assay date
03 Dec 2024
Submitted
22 Dec 2024
Quarter
2024-Q4
Submitter
label_claim
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the non-peptide adjuncts class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 30 min gradient, 214 nm99.14% area≥ 98.0PASS
Total impuritiesRP-HPLC, sum of reported peaks0.86% area≤ 2.0PASS
Largest single impurityRP-HPLC — 1-methylquinolinium (des-amino, −15 Da)0.61% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula285.9967DaNOT TESTED
Identity — observed monoisotopic massLC-MS, high resolution (ESI-TOF/QTOF)285.9963DaNOT TESTED
Mass accuracyobserved vs theoretical-1.4ppm± 10PASS
Total peptide contentby difference from the gravimetric mass balance54.89%w/wNOT TESTED
Target-compound contenttotal peptide content × purity54.42%w/wNOT TESTED
Gross fill (as weighed)five-place balance, under nitrogen93.67mg50 mg declaredNOT TESTED
Recovered target peptidegross fill × target content50.975mg50 mg claimNOT TESTED
Recovery against label claimrecovered ÷ claim102.0%90.0 – 110.0PASS
Water contentKarl Fischer, coulometric, duplicate2.23%≤ 10.0PASS
Counter-ion (iodide)anion-exchange ion chromatography42.37%≤ 12.0FAIL
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.51%NOT TESTED
Endotoxinkinetic chromogenic LAL0.47EU/mg≤ 5.0PASS
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration5.352.5 – 8.0PASS
Retention time (observed)RP-HPLC, 30 min gradient5.40min5.42 ± 0.25 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.020.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²47,442≥ 20,000PASS
Resolution to nearest impurityvs free iodide (counter-ion, by IC)0.00no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

0458691731375918345 5-Amino-1MQ5.40 min · 99.14 % 5.08 same trace · ×100 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 05101520253035 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 30 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 47,442, and skew follows the reported asymmetry factor of 1.02. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.61 % impurity against a 99.14 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
15-Amino-1MQ — main peak5.404,818,51199.14
21-methylquinolinium (des-amino, −15 Da)5.0829,6480.61-15.011
35-nitro-1MQ (unreduced precursor, +30 Da)6.087,2900.15+29.974
4free iodide (counter-ion, by IC)5.403,4020.070.000
58-amino regioisomer5.621,4580.030.000
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 285.9967 Da, computed from C10H11N2+ · I−. All ppm figures on this site are against monoisotopic values — see why that matters.

0255075100250275300325350375 [M+1H]1+287.00 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, high-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 285.9963 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
1+287.0040287.0036-0.0004100.0
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

ComponentDetermination%w/w of cake
WaterKarl Fischer2.23
Counter-ion (iodide)ion chromatography42.37
Residual solvent + inorganic residueestimated0.51
Total peptide contentby difference54.89
Total100.00 CLOSES

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.099.14divergence -0.14 pp vs batch median
Total impurities (% area)1.000.86
Largest single impurity (% area)0.390.61
Water (%)not stated2.23
Counter-ion (%)not stated42.37
Peptide content (%w/w)91.754.89
Endotoxin (EU/mg)not stated0.47
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → submitter (−20 °C, 16 d) → laboratory (courier, dry ice, 11 d) → assay.
Assay date
03 Dec 2024
Submitted to the index
22 Dec 2024
Laboratory
Janoshik Analytical, Ostrava, Czechia
Method basis
30 min gradient · high-resolution MS
Verification status
VERIFIED
Section 6

Annotations 3

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

sig_figs
A figure reported to the nearest half point is reporting less precision than the method has, which is the opposite of the usual complaint. It is conservative rather than optimistic.
bland_altman
Where two laboratories tested the same retail lot, the paired difference is a clean estimate of inter-lab bias with no selection term in it at all. Those pairs are the backbone of the agreement analysis.
coa_reader
The supplier's own declaration is printed beside the index's balance on this page. Comparing the two is the point of publishing both and rule AX-R07 is about the comparison.
Section 7

Related records

Same batch — lot TFC-2406-A1769 n=5

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2024-004605TFC-2406-A1769VendorInvestigate2024-Q498.902.6694.7Laboratory-retained2FAIL
AX-2024-004606TFC-2406-A1769Janoshik2024-Q499.092.35101.1Buyer-sourced1FAIL
AX-2024-004607TFC-2406-A1769PeptideMeter2024-Q499.582.6890.3Buyer-sourced1FAIL
AX-2024-004608TFC-2406-A1769PeptideMeter2024-Q499.161.94102.5Buyer-sourced1FAIL
Other recent 5-Amino-1MQ records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043050KPKP-2511-W5347Janoshik2026-Q299.354.16105.5Buyer-sourced0FAIL
AX-2026-043044KPKP-2511-W5347PeptideMeter2026-Q299.614.1590.9Buyer-sourced0FAIL
AX-2026-043052KPKP-2511-W5347Medutest2026-Q299.454.23105.5Buyer-sourced1FAIL
AX-2026-043045KPKP-2511-W5347Janoshik2026-Q299.474.08Buyer-sourced0FAIL
AX-2026-043043KPKP-2511-W5347Janoshik2026-Q299.584.16101.1Buyer-sourced0FAIL
AX-2026-042869GGPepsGGPE-2512-M2434Kestrel2026-Q299.554.65103.9Buyer-sourced0FAIL
AX-2026-042868GGPepsGGPE-2512-M2434PeptideMeter2026-Q299.324.3988.5Buyer-sourced1FAIL
AX-2026-043047KPKP-2511-W5347Janoshik2026-Q299.684.17104.0Supplier-supplied0FAIL
Other recent TFC records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042265Humanin (HNG)TFC-2605-U1300PeptideMeter2026-Q399.526.31Buyer-sourced0PASS
AX-2026-042222SS-31 (Elamipretide)TFC-2607-R9099VendorInvestigate2026-Q399.465.41102.6Buyer-sourced0PASS
AX-2026-042236Humanin (HNG)TFC-2608-S9940Nordanalyt2026-Q398.641.80Buyer-sourced0PASS
AX-2026-042282RetatrutideTFC-2608-J1156Janoshik2026-Q398.544.27Buyer-sourced0PASS
AX-2026-042226SS-31 (Elamipretide)TFC-2607-R9099Janoshik2026-Q399.625.47Buyer-sourced0PASS
AX-2026-042217SemaglutideTFC-2604-X9037PeptideMeter2026-Q398.954.6196.9Buyer-sourced0PASS
AX-2026-042339SermorelinTFC-2605-Y2176Kestrel2026-Q399.934.14Supplier-supplied1FAIL
AX-2026-042214SemaglutideTFC-2604-X9037Kestrel2026-Q399.874.66103.1Laboratory-retained0PASS