AssayIndex

AX-2024-004449

Semax · 10 mg declared · GenScript Biotech Corporation · lot GSP-2408-K2819

PASSVERIFIED
Report ID
AX-2024-004449
Compound
Semax
Compound class
Neuroactive and cognitive peptides
Supplier
GSP — GenScript Biotech Corporation
Batch / lot
GSP-2408-K2819
Declared label claim
10mg
Laboratory
PeptideMeter
Assay date
26 Oct 2024
Submitted
10 Nov 2024
Quarter
2024-Q4
Submitter
so.beaulieu
Sample provenance
Supplier-supplied
Section 1

Results

Measured against the index acceptance specification for the neuroactive and cognitive peptides class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 28 min gradient, 214 nm99.93% area≥ 98.5PASS
Total impuritiesRP-HPLC, sum of reported peaks0.07% area≤ 1.5PASS
Largest single impurityRP-HPLC — Met1 sulfoxide (+16 Da)0.05% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula813.3541DaNOT TESTED
Identity — observed monoisotopic massLC-MS, high resolution (ESI-TOF/QTOF)813.3582DaNOT TESTED
Mass accuracyobserved vs theoretical+5.0ppm± 15PASS
Total peptide contentby difference from the gravimetric mass balance84.84%w/wNOT TESTED
Target-compound contenttotal peptide content × purity84.78%w/wNOT TESTED
Gross fill (as weighed)five-place balance, under nitrogen12.20mg10 mg declaredNOT TESTED
Recovered target peptidegross fill × target content10.343mg10 mg claimNOT TESTED
Recovery against label claimrecovered ÷ claim103.4%90.0 – 110.0PASS
Water contentKarl Fischer, coulometric, duplicate6.69%≤ 12.0PASS
Counter-ion (acetate)anion-exchange ion chromatography7.76%≤ 10.0PASS
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.71%NOT TESTED
Endotoxinkinetic chromogenic LAL0.64EU/mg≤ 5.0PASS
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundOff-white lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration4.952.5 – 8.0PASS
Retention time (observed)RP-HPLC, 28 min gradient6.82min6.63 ± 0.25 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.170.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²89,723≥ 20,000PASS
Resolution to nearest impurityvs Met1 sulfoxide (+16 Da)3.60no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

0468293651404718730 Semax6.82 min · 99.93 % 6.48 same trace · ×200 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 051015202530 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 28 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 89,723, and skew follows the reported asymmetry factor of 1.17. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.05 % impurity against a 99.93 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1Semax — main peak6.824,856,90899.93
2Met1 sulfoxide (+16 Da)6.482,4300.05+15.995
3N-acetyl semax (+42 Da)7.219720.02+42.011
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 813.3541 Da, computed from C37H51N9O10S. All ppm figures on this site are against monoisotopic values — see why that matters.

0255075100350450550650750850 [M+1H]1+814.37[M+2H]2+407.69 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, high-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 813.3582 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
2+407.6843407.68640.002156.4
1+814.3614814.36550.0041100.0
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

ComponentDetermination%w/w of cake
WaterKarl Fischer6.69
Counter-ion (acetate)ion chromatography7.76
Residual solvent + inorganic residueestimated0.71
Total peptide contentby difference84.84
Total100.00 CLOSES

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.9099.93divergence +0.05 pp vs batch median
Total impurities (% area)0.100.07
Largest single impurity (% area)0.050.05
Water (%)not stated6.69
Counter-ion (%)not stated7.76
Peptide content (%w/w)not stated84.84
Endotoxin (EU/mg)0.400.64
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Supplier-supplied
Evidentiary weight
Weaker evidence. Read with the caveat below.
Chain of custody
Supplier despatch → laboratory direct (courier, cold pack, 7 d) → assay. Submitter did not handle the vial.
Assay date
26 Oct 2024
Submitted to the index
10 Nov 2024
Laboratory
PeptideMeter, Tallinn, Estonia
Method basis
28 min gradient · high-resolution MS
Verification status
VERIFIED
Section 6

Annotations 2

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

ppm_error
Instrument was evidently in calibration on the day. A run of results at this accuracy across a laboratory's sequence is the background against which an excursion becomes interpretable.
sole_source
On compounds where a single supplier is the entire evidence base, refusing supplier-supplied material would mean publishing nothing. The index publishes it and labels it, which is the lesser of the two failures.
Section 7

Related records

Same batch — lot GSP-2408-K2819 n=2

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2024-004448GSP-2408-K2819VendorInvestigate2024-Q499.776.58Buyer-sourced0PASS
Other recent Semax records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042519HomopeptideHOMO-2605-S5227Medutest2026-Q399.755.55Buyer-sourced0PASS
AX-2026-042517HomopeptideHOMO-2605-S5227Janoshik2026-Q399.925.88Buyer-sourced0PASS
AX-2026-042518HomopeptideHOMO-2605-S5227Janoshik2026-Q399.765.61Buyer-sourced0PASS
AX-2026-042524HomopeptideHOMO-2605-S5227Janoshik2026-Q399.935.75100.9Supplier-supplied0PASS
AX-2026-042516HomopeptideHOMO-2605-S5227Janoshik2026-Q399.935.8795.1Buyer-sourced0PASS
AX-2026-042522HomopeptideHOMO-2605-S5227Nordanalyt2026-Q399.935.49Buyer-sourced0PASS
AX-2026-042520HomopeptideHOMO-2605-S5227Medutest2026-Q399.936.12Buyer-sourced0PASS
AX-2026-042514HomopeptideHOMO-2605-S5227Janoshik2026-Q399.595.4897.0Buyer-sourced0PASS
Other recent GSP records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041831SurvodutideGSP-2603-E3156Kestrel2026-Q399.915.5093.2Buyer-sourced0PASS
AX-2026-041836SurvodutideGSP-2603-E3156Janoshik2026-Q398.655.3490.3Buyer-sourced0PASS
AX-2026-041837SurvodutideGSP-2603-E3156Janoshik2026-Q398.335.37Buyer-sourced0PASS
AX-2026-041833SurvodutideGSP-2603-E3156Janoshik2026-Q398.084.9199.3Buyer-sourced0PASS
AX-2026-041832SurvodutideGSP-2603-E3156VendorInvestigate2026-Q398.015.1499.5Buyer-sourced0PASS
AX-2026-041835SurvodutideGSP-2603-E3156Nordanalyt2026-Q398.345.7489.0Buyer-sourced1MARGINAL
AX-2026-041834SurvodutideGSP-2603-E3156VendorInvestigate2026-Q397.925.95Buyer-sourced0PASS