AssayIndex

AX-2024-004327

CJC-1295 (no DAC) · 5 mg declared · Qingdao Sigma Chemical Co., Ltd. · lot QSC-2410-L7328

PASSPURITY ONLY
Report ID
AX-2024-004327
Compound
CJC-1295 (no DAC)
Compound class
Growth-hormone axis peptides
Supplier
QSC — Qingdao Sigma Chemical Co., Ltd.
Batch / lot
QSC-2410-L7328
Declared label claim
5mg
Laboratory
Kestrel Bioanalytical
Assay date
21 Nov 2024
Submitted
06 Dec 2024
Quarter
2024-Q4
Submitter
l.rahimi
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the growth-hormone axis peptides class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 15 min gradient, 214 nm99.93% area≥ 98.0PASS
Total impuritiesRP-HPLC, sum of reported peaks0.07% area≤ 2.0PASS
Largest single impurityRP-HPLC — deamidated (+1 Da)0.04% area≤ 1.00PASS
Identitynot ordered on this submissionnot determinedrequired for VERIFIED statusNOT TESTED
Peptide contentnot ordered on this submissionnot determinedrequired to check label claimNOT TESTED
Water contentKarl Fischer, coulometric, duplicate6.24%≤ 9.0PASS
Counter-ion (acetate)anion-exchange ion chromatography5.72%≤ 12.0PASS
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.64%NOT TESTED
Endotoxinkinetic chromogenic LAL0.35EU/mg≤ 5.0PASS
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundWhite lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration5.082.5 – 8.0PASS
Retention time (observed)RP-HPLC, 15 min gradient6.96min6.94 ± 0.30 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.160.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²60,471≥ 20,000PASS
Resolution to nearest impurityvs deamidated (+1 Da)1.03no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

0378475691135315137 CJC-1295 (no DAC)6.96 min · 99.93 % 6.84 same trace · ×200 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 048121620 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 15 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 60,471, and skew follows the reported asymmetry factor of 1.16. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.04 % impurity against a 99.93 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1CJC-1295 (no DAC) — main peak6.964,856,90899.93
2deamidated (+1 Da)6.841,9440.04+0.984
3native GRF (1-29) (−59 Da)6.791,4580.03-58.995
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.9099.93divergence -0.03 pp vs batch median
Total impurities (% area)0.100.07
Largest single impurity (% area)0.060.04
Water (%)5.96.24
Counter-ion (%)8.35.72
Peptide content (%w/w)85.2not determined
Endotoxin (EU/mg)not stated0.35
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → submitter (ambient, 6 d) → laboratory (courier, cold pack, 6 d) → assay.
Assay date
21 Nov 2024
Submitted to the index
06 Dec 2024
Laboratory
Kestrel Bioanalytical, Melbourne, Australia
Method basis
15 min gradient · unit-resolution MS
Verification status
PURITY ONLY
Section 6

Annotations 2

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

lot_traceability
Lot QSC-2410-L7328 decodes to a manufacture date consistent with the custody chain above. Traceability plus 99.93 % is a complete story; either alone is half of one.
storage_stated
Purity 99.93 %, water 6.24 %, counter-ion 5.72 % acetate, mass balance closed, provenance independent. There is nothing outstanding on this record.
Section 7

Related records

Same batch — lot QSC-2410-L7328 n=6

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2024-004324QSC-2410-L7328Janoshik2024-Q499.936.6794.3Laboratory-retained0PASS
AX-2024-004325QSC-2410-L7328Janoshik2024-Q499.937.06104.4Buyer-sourced0PASS
AX-2024-004326QSC-2410-L7328Janoshik2024-Q499.936.55Buyer-sourced0PASS
AX-2024-004328QSC-2410-L7328Medutest2024-Q499.476.81Buyer-sourced0PASS
AX-2024-004329QSC-2410-L7328PeptideMeter2024-Q499.886.28Buyer-sourced0PASS
Other recent CJC-1295 (no DAC) records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042942MKMMKM-2603-V3346Janoshik2026-Q399.523.43Supplier-supplied0PASS
AX-2026-041599QSCQSC-2606-V7416VendorInvestigate2026-Q397.963.52Buyer-sourced1FAIL
AX-2026-042784GGPepsGGPE-2606-E1234Medutest2026-Q398.274.55Buyer-sourced0PASS
AX-2026-042939MKMMKM-2603-V3346PeptideMeter2026-Q399.443.39Buyer-sourced0PASS
AX-2026-041601QSCQSC-2606-V7416Kestrel2026-Q398.334.10Buyer-sourced1MARGINAL
AX-2026-042945MKMMKM-2603-V3346PeptideMeter2026-Q399.393.54Laboratory-retained0PASS
AX-2026-042786GGPepsGGPE-2606-E1234Janoshik2026-Q398.223.77Buyer-sourced0PASS
AX-2026-041602QSCQSC-2606-V7416VendorInvestigate2026-Q398.363.38101.8Buyer-sourced1MARGINAL
Other recent QSC records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041599CJC-1295 (no DAC)QSC-2606-V7416VendorInvestigate2026-Q397.963.52Buyer-sourced1FAIL
AX-2026-041601CJC-1295 (no DAC)QSC-2606-V7416Kestrel2026-Q398.334.10Buyer-sourced1MARGINAL
AX-2026-041602CJC-1295 (no DAC)QSC-2606-V7416VendorInvestigate2026-Q398.363.38101.8Buyer-sourced1MARGINAL
AX-2026-041477TriptorelinQSC-2607-C5749Nordanalyt2026-Q399.533.42Buyer-sourced0PASS
AX-2026-041600CJC-1295 (no DAC)QSC-2606-V7416Nordanalyt2026-Q397.744.91100.9Buyer-sourced1FAIL
AX-2026-041603CJC-1295 (no DAC)QSC-2606-V7416PeptideMeter2026-Q398.434.20Buyer-sourced1MARGINAL
AX-2026-041606CJC-1295 (no DAC)QSC-2606-V7416Janoshik2026-Q398.033.58Buyer-sourced1MARGINAL
AX-2026-041585LiraglutideQSC-2605-W7381Medutest2026-Q399.595.0992.8Laboratory-retained0PASS