AssayIndex
Submitter and annotator

uncertainty_budget

Combined standard uncertainty for a purity figure. Nobody publishes one.

first seen 2025-Q16 records submitted174 annotations
Section 1

Contribution

Both submits records and annotates other people's.

Records submitted 6 n=6
Annotations 174 n=174
Median purity submitted 99.12% n=6
Suppliers covered 5 n=6
Section 2

Records submitted

A submitter chose to buy this material and to pay for this assay. That choice is the selection mechanism behind the whole index and it is not random.

ReportCompoundSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042004SemaglutideAMBAMB-2607-N6274Medutest2026-Q397.746.45Buyer-sourced1MARGINAL
AX-2026-043348LeuprolideWXTWXT-2604-K2596Janoshik2026-Q398.705.7499.0Buyer-sourced0PASS
AX-2025-018791SemaglutideFGPFGP-2506-J7851VendorInvestigate2025-Q499.934.5491.2Buyer-sourced1MARGINAL
AX-2025-020307MK-677 (Ibutamoren mesylate)GGPepsGGPE-2507-S2892PeptideMeter2025-Q399.794.4794.6Buyer-sourced0FAIL
AX-2024-004911RetatrutideGGPepsGGPE-2411-R9634PeptideMeter2024-Q498.985.8199.9Buyer-sourced0PASS
AX-2024-004127SemaxWWBWWB-2308-N1754Janoshik2024-Q199.265.4993.9Buyer-sourced0PASS
SupplierRecordsMedian purity
GGPeps2n<3
AMB1n<3
WXT1n<3
FGP1n<3
WWB1n<3
Section 3

Annotations

Signed technical comments on records. The index does not moderate annotations for agreement with its own arithmetic, and several of these disagree with it. Where a handle has made the same point on several records, one instance is shown and the rest are reachable from the records themselves.

AX-2026-042942
Purity at 99.52 % and water at 3.43 %: the two numbers are independent and both are needed. Excellent chromatography on a wet cake still yields less peptide per vial than the label implies.
AX-2026-041909
Integration boundary on a close pair contributes up to 0.45 pp of standard uncertainty on its own. That is the term to quote alongside 99.00 % rather than a resolution verdict.
AX-2026-041637
Expanded uncertainty on a well-resolved main peak is about ±0.48 pp at 95 % confidence. 99.40 % should be read as a band, and the band is still comfortably above the class specification.
AX-2026-042938
Expanded uncertainty on a well-resolved main peak is about ±0.48 pp at 95 % confidence. 99.47 % should be read as a band, and the band is still comfortably above the class specification.
AX-2026-042020
Expanded uncertainty on a well-resolved main peak is about ±0.48 pp at 95 % confidence. 99.53 % should be read as a band, and the band is still comfortably above the class specification.
AX-2026-041258
Expanded uncertainty on a well-resolved main peak is about ±0.48 pp at 95 % confidence. 99.36 % should be read as a band, and the band is still comfortably above the class specification.
AX-2026-041331
Expanded uncertainty on a well-resolved main peak is about ±0.48 pp at 95 % confidence. 99.37 % should be read as a band, and the band is still comfortably above the class specification.
AX-2026-042163
Expanded uncertainty on a well-resolved main peak is about ±0.48 pp at 95 % confidence. 99.46 % should be read as a band, and the band is still comfortably above the class specification.
AX-2026-043427
The gap between 97.67 % and the class specification should be read against an expanded uncertainty of roughly ±0.5 pp. A shortfall inside that band is not a finding; a shortfall well outside it is.
AX-2026-043434
The gap between 97.95 % and the class specification should be read against an expanded uncertainty of roughly ±0.5 pp. A shortfall inside that band is not a finding; a shortfall well outside it is.
AX-2026-042425
Integration boundary on a close pair contributes up to 0.45 pp of standard uncertainty on its own. That is the term to quote alongside 99.17 % rather than a resolution verdict.
AX-2026-041964
Expanded uncertainty on a well-resolved main peak is about ±0.48 pp at 95 % confidence. 99.93 % should be read as a band, and the band is still comfortably above the class specification.

Showing 12 distinct comments of 174 annotations by this handle.