AssayIndex
Cross-section

TB-500 by laboratory

The same compound measured by different laboratories on different gradients. Where the medians differ, the question is whether the material differed or the method did — and for TB-500, with a class minimum gradient of 15 min, the method is a live explanation.

268 recordsmedian 99.53 %spec 98.5 %
LaboratoryReportsGradientMS resolutionMedian purity %Published bias (pp)Bias-adjustedMethod suitability
Janoshik12630minHigh99.50+0.0099.50ADEQUATE
PeptideMeter4728minHigh99.51-0.0599.56ADEQUATE
Medutest3525minUnit99.79+0.0899.71ADEQUATE
VendorInvestigate2432minHigh99.42-0.1199.53ADEQUATE
Nordanalyt2135minHigh99.57+0.0299.55ADEQUATE
Kestrel1515minUnit99.75+0.2499.51ADEQUATE
97.698.098.498.999.399.7100.1JanoshikJanoshik: Q1 99.24, median 99.50, Q3 99.75, n=126outlier 97.79outlier 98.03outlier 98.23outlier 98.37outlier 98.42outlier 98.47n=126PeptideMeterPeptideMeter: Q1 99.30, median 99.51, Q3 99.87, n=47outlier 97.85outlier 98.18n=47MedutestMedutest: Q1 99.10, median 99.79, Q3 99.93, n=35outlier 97.83n=35VendorInvestigateVendorInvestigate: Q1 98.97, median 99.42, Q3 99.60, n=24n=24NordanalytNordanalyt: Q1 99.41, median 99.57, Q3 99.79, n=21outlier 98.45outlier 98.50outlier 98.58n=21KestrelKestrel: Q1 99.53, median 99.75, Q3 99.93, n=15outlier 98.79n=15 Purity (% area)
Figure. TB-500 purity by contributing laboratory. Any offset between rows has two possible sources — a real difference in the material each laboratory happened to receive, and the laboratory's own bias — and this figure cannot separate them. The paired analysis that can is on inter-lab agreement.