Semax by laboratory

The same compound measured by different laboratories on different gradients. Where the medians differ, the question is whether the material differed or the method did — and for Semax, with a class minimum gradient of 15 min, the method is a live explanation.

216 recordsmedian 99.46 %spec 98.5 %
LaboratoryReportsGradientMS resolutionMedian purity %Published bias (pp)Bias-adjustedMethod suitability
Janoshik9930minHigh99.51+0.0099.51ADEQUATE
PeptideMeter3928minHigh99.27-0.0599.32ADEQUATE
Medutest3125minUnit99.66+0.0899.58ADEQUATE
VendorInvestigate2132minHigh99.09-0.1199.20ADEQUATE
Nordanalyt1635minHigh99.59+0.0299.57ADEQUATE
Kestrel1015minUnit99.46+0.2499.22ADEQUATE
97.397.898.398.799.299.7100.1JanoshikJanoshik: Q1 99.03, median 99.51, Q3 99.72, n=99n=99PeptideMeterPeptideMeter: Q1 98.90, median 99.27, Q3 99.62, n=39n=39MedutestMedutest: Q1 99.17, median 99.66, Q3 99.93, n=31outlier 97.54outlier 97.87n=31VendorInvestigateVendorInvestigate: Q1 98.67, median 99.09, Q3 99.27, n=21n=21NordanalytNordanalyt: Q1 99.20, median 99.59, Q3 99.78, n=16n=16KestrelKestrel: Q1 99.14, median 99.46, Q3 99.88, n=10n=10 Purity (% area)
Figure. Semax purity by contributing laboratory. Any offset between rows has two possible sources — a real difference in the material each laboratory happened to receive, and the laboratory's own bias — and this figure cannot separate them. The paired analysis that can is on inter-lab agreement.