Semaglutide by laboratory
The same compound measured by different laboratories on different gradients. Where the medians differ, the question is whether the material differed or the method did — and for Semaglutide, with a class minimum gradient of 25 min, the method is a live explanation.
| Laboratory | Reports | Gradient | MS resolution | Median purity % | Published bias (pp) | Bias-adjusted | Method suitability |
|---|---|---|---|---|---|---|---|
| Janoshik | 343 | 30min | High | 98.88 | +0.00 | 98.88 | ADEQUATE |
| PeptideMeter | 118 | 28min | High | 98.76 | -0.05 | 98.81 | ADEQUATE |
| Medutest | 106 | 25min | Unit | 98.89 | +0.08 | 98.81 | ADEQUATE |
| VendorInvestigate | 78 | 32min | High | 98.71 | -0.11 | 98.82 | ADEQUATE |
| Nordanalyt | 75 | 35min | High | 99.01 | +0.02 | 98.99 | ADEQUATE |
| Kestrel | 48 | 15min | Unit | 99.78 | +0.24 | 99.54 | BELOW CLASS MINIMUM |