AssayIndex

SWB-2403-W7867

Exenatide · 10 mg declared · Shanghai Wibson Biotechnology Co., Ltd. · manufactured 21 Mar 2024

CHARACTERISED
Lot code
SWB-2403-W7867
Supplier
SWB — Shanghai Wibson Biotechnology Co., Ltd.
Compound
Exenatide
Compound class
Incretin analogues and co-agonists
Declared label claim
10mg
Manufacture date
21 Mar 2024
Index quarter
2024-Q3
Independent assays
4
Laboratories involved
Nordanalyt, Janoshik
Provenance mix
Buyer-sourced ×4
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 4
Median purity 99.42% n=4
Spread (max − min) 0.11pp n=4
Standard deviation 0.045pp n=4
97.798.198.598.999.399.7100.1This lot (SWB-2403-W7867)This lot (SWB-2403-W7867): Q1 99.39, median 99.41, Q3 99.43, n=4n=4All ExenatideAll Exenatide: Q1 98.61, median 98.98, Q3 99.32, n=49n=49 Purity (% area)
Figure 1. This lot's independent purity results against the whole Exenatide record set in the index. The vertical line is the index acceptance specification for the incretin analogues and co-agonists class, 98.0 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 4

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2024-004829SWB-2403-W7867Nordanalyt2024-Q399.413.3299.3Buyer-sourced1MARGINAL
AX-2024-004830SWB-2403-W7867Janoshik2024-Q399.353.03105.4Buyer-sourced1MARGINAL
AX-2024-004831SWB-2403-W7867Nordanalyt2024-Q399.423.20Buyer-sourced1MARGINAL
AX-2024-004832SWB-2403-W7867Janoshik2024-Q399.463.3596.4Buyer-sourced1MARGINAL
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
Nordanalyt299.41, 99.4299.4135min+0.0299.39
Janoshik299.35, 99.4699.4130min+0.0099.41

This lot contributes 1 paired comparison to the inter-lab analysis.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)99.9099.41divergence +0.48 pp vs batch median
Total impurities (% area)0.040.59
Largest single impurity (% area)0.100.41
Water (%)not stated3.32
Counter-ion (%)not stated4.02
Peptide content (%w/w)91.792.39
Endotoxin (EU/mg)not statednot determined
Method stated on certificateNOno method section — the result cannot be reconciled against any other
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
truncated (1-38)4 / 40.220.02–0.41
des-Gly1 truncate (−57 Da)4 / 40.160.04–0.39
Met14 sulfoxide (+16 Da)4 / 40.110.03–0.17
Trp25 oxidation (+16 Da)3 / 40.100.03–0.10
C-terminal free acid (+1 Da)2 / 40.060.04–0.07
Section 7

What this rollup does not establish