AssayIndex

AX-2026-043219

GHRP-6 · 2 mg declared · Sangon Biotech (Shanghai) Co., Ltd. · lot SGN-2510-P8974

FAILIDENTITY CONSISTENT
Report ID
AX-2026-043219
Compound
GHRP-6
Compound class
Growth-hormone axis peptides
Supplier
SGN — Sangon Biotech (Shanghai) Co., Ltd.
Batch / lot
SGN-2510-P8974
Declared label claim
2mg
Laboratory
Medutest
Assay date
12 Feb 2026
Submitted
23 Feb 2026
Quarter
2026-Q1
Submitter
r.wojcik
Sample provenance
Laboratory-retained
Section 1

Results

Measured against the index acceptance specification for the growth-hormone axis peptides class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 25 min gradient, 214 nm98.89% area≥ 99.0FAIL
Total impuritiesRP-HPLC, sum of reported peaks1.11% area≤ 1.0FAIL
Largest single impurityRP-HPLC — [D-Trp]-epimer0.55% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula872.4446DaNOT TESTED
Identity — observed monoisotopic massLC-MS, unit resolution (single quadrupole)872.4610DaNOT TESTED
Mass accuracyobserved vs theoretical+18.8ppm± 15FAIL
Peptide contentnot ordered on this submissionnot determinedrequired to check label claimNOT TESTED
Water contentKarl Fischer, coulometric, duplicate1.56%≤ 9.0PASS
Counter-ion (acetate)anion-exchange ion chromatography6.28%≤ 12.0PASS
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.53%NOT TESTED
Endotoxinkinetic chromogenic LAL0.36EU/mg≤ 5.0PASS
Sterilitymembrane filtration, USP <71>, 14 dNo growth at 14 dno growthPASS
Appearancevisual, diffuse light, black and white backgroundWhite lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration4.342.5 – 8.0PASS
Retention time (observed)RP-HPLC, 25 min gradient7.16min7.15 ± 0.25 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.260.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²66,578≥ 20,000PASS
Resolution to nearest impurityvs [D-Trp]-epimer0.88no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

0365173021095314604 GHRP-67.16 min · 98.89 % 7.06 same trace · ×100 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 0481216202428 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 25 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 66,578, and skew follows the reported asymmetry factor of 1.26. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.55 % impurity against a 98.89 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1GHRP-6 — main peak7.164,806,36198.89
2[D-Trp]-epimer7.0626,7320.550.000
3oxidised Trp (+16 Da)6.8817,4970.36+15.995
4des-Lys (−128 Da)6.985,3460.11-128.095
5bis-oxidised Trp (+32 Da)6.684,3740.09+31.990
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 872.4446 Da, computed from C46H56N12O6. All ppm figures on this site are against monoisotopic values — see why that matters.

0255075100375475575675775875975 [M+1H]1+873.47[M+2H]2+437.24 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, unit-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 872.4610 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
2+437.2296437.23780.008253.2
1+873.4519873.46830.0164100.0
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.0298.89divergence +0.13 pp vs batch median
Total impurities (% area)0.981.11
Largest single impurity (% area)0.460.55
Water (%)0.61.56
Counter-ion (%)9.36.28
Peptide content (%w/w)89.5not determined
Endotoxin (EU/mg)not stated0.36
Method stated on certificateNOno method section — the result cannot be reconciled against any other
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Laboratory-retained
Evidentiary weight
Provenance documented, selection uncontrolled.
Chain of custody
Laboratory retained sample (−20 °C, 15 d since original receipt) → re-assay.
Assay date
12 Feb 2026
Submitted to the index
23 Feb 2026
Laboratory
Medutest, Ljubljana, Slovenia
Method basis
25 min gradient · unit-resolution MS
Verification status
IDENTITY CONSISTENT
Section 6

Annotations 4

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

area_percent
Area percent with assumed unit response factors gets less reliable as impurity content rises. At 1.11 % total impurities the response-factor assumption is worth about a tenth of a point, which is small next to the gap but not nothing.
low_n
n=1 on this lot. A single result below specification is a finding about a vial. Two agreeing results would make it a finding about a lot, and the batch page will say which of those exists.
sodium_adduct
An unrecognised sodium adduct shifts an apparent monoisotopic mass by about 22 Da, which at this molecular weight is far more than +18.8 ppm. Rule that out first; it is the cheapest check available.
ppm_error
The distribution of ppm error by instrument class in this index is wide enough that a single figure like +18.8 ppm carries little on its own. What carries is whether the same instrument produced similar excursions on adjacent runs, and the laboratory page has that.
Section 7

Related records

Same batch — lot SGN-2510-P8974 n=7

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043213SGN-2510-P8974Janoshik2026-Q198.722.30Buyer-sourced0FAIL
AX-2026-043214SGN-2510-P8974Medutest2026-Q199.651.24Supplier-supplied1MARGINAL
AX-2026-043215SGN-2510-P8974Janoshik2026-Q198.521.66107.4Buyer-sourced0FAIL
AX-2026-043216SGN-2510-P8974Medutest2026-Q199.821.5089.0Supplier-supplied3FAIL
AX-2026-043217SGN-2510-P8974Medutest2026-Q198.882.28Buyer-sourced0FAIL
AX-2026-043218SGN-2510-P8974PeptideMeter2026-Q199.441.03Buyer-sourced1MARGINAL
Other recent GHRP-6 records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042012AMBAMB-2603-S5667Janoshik2026-Q399.375.9088.8Laboratory-retained1MARGINAL
AX-2026-042528HJHJ-2603-R5329VendorInvestigate2026-Q398.691.8795.8Buyer-sourced0FAIL
AX-2026-042015AMBAMB-2603-S5667Janoshik2026-Q399.546.4497.1Buyer-sourced0PASS
AX-2026-042526HJHJ-2603-R5329Medutest2026-Q399.373.06Laboratory-retained0PASS
AX-2026-042527HJHJ-2603-R5329VendorInvestigate2026-Q399.212.7793.2Buyer-sourced0PASS
AX-2026-042525HJHJ-2603-R5329Janoshik2026-Q399.523.2492.0Buyer-sourced0PASS
AX-2026-042013AMBAMB-2603-S5667Kestrel2026-Q399.935.75Buyer-sourced0PASS
AX-2026-042017AMBAMB-2603-S5667Medutest2026-Q399.766.4297.4Buyer-sourced0PASS
Other recent SGN records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043233AfamelanotideSGN-2602-Y9306Janoshik2026-Q398.764.0292.2Buyer-sourced1MARGINAL
AX-2026-043234AfamelanotideSGN-2602-Y9306Kestrel2026-Q399.934.16Buyer-sourced0PASS
AX-2026-043240SLU-PP-332SGN-2602-X9377Janoshik2026-Q298.825.4697.0Buyer-sourced0PASS
AX-2026-043222ARA-290SGN-2605-X9069PeptideMeter2026-Q298.327.36Buyer-sourced0PASS
AX-2026-043237SLU-PP-332SGN-2602-X9377Janoshik2026-Q298.476.22100.0Supplier-supplied0PASS
AX-2026-043227ARA-290SGN-2605-X9069PeptideMeter2026-Q298.387.2195.6Buyer-sourced0PASS
AX-2026-043239SLU-PP-332SGN-2602-X9377VendorInvestigate2026-Q298.285.37Buyer-sourced0PASS