AssayIndex

AX-2025-020651

GHRP-6 · 2 mg declared · Sangon Biotech (Shanghai) Co., Ltd. · lot SGN-2411-N8496

FAILIDENTITY CONSISTENT
Report ID
AX-2025-020651
Compound
GHRP-6
Compound class
Growth-hormone axis peptides
Supplier
SGN — Sangon Biotech (Shanghai) Co., Ltd.
Batch / lot
SGN-2411-N8496
Declared label claim
2mg
Laboratory
Medutest
Assay date
24 Mar 2025
Submitted
25 Mar 2025
Quarter
2025-Q1
Submitter
e.salgado
Sample provenance
Buyer-sourced
Section 1

Results

Measured against the index acceptance specification for the growth-hormone axis peptides class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 25 min gradient, 214 nm99.54% area≥ 99.0PASS
Total impuritiesRP-HPLC, sum of reported peaks0.46% area≤ 1.0PASS
Largest single impurityRP-HPLC — [D-Trp]-epimer0.31% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula872.4446DaNOT TESTED
Identity — observed monoisotopic massLC-MS, unit resolution (single quadrupole)872.4259DaNOT TESTED
Mass accuracyobserved vs theoretical-21.4ppm± 15FAIL
Total peptide contentby difference from the gravimetric mass balance91.70%w/wNOT TESTED
Target-compound contenttotal peptide content × purity91.28%w/wNOT TESTED
Gross fill (as weighed)five-place balance, under nitrogen2.33mg2 mg declaredNOT TESTED
Recovered target peptidegross fill × target content2.127mg2 mg claimNOT TESTED
Recovery against label claimrecovered ÷ claim106.4%90.0 – 110.0PASS
Water contentKarl Fischer, coulometric, duplicate3.75%≤ 9.0PASS
Counter-ion (acetate)anion-exchange ion chromatography4.16%≤ 12.0PASS
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.39%NOT TESTED
Endotoxinnot ordered on this submissionnot determined≤ 5.0NOT TESTED
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundOff-white lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear after 90 s gentle swirling, no particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration4.952.5 – 8.0PASS
Retention time (observed)RP-HPLC, 25 min gradient7.16min7.15 ± 0.25 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.461.060.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²59,182≥ 20,000PASS
Resolution to nearest impurityvs [D-Trp]-epimer0.83no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

0380176021140315204 GHRP-67.16 min · 99.54 % 7.06 same trace · ×200 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 0481216202428 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 25 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 59,182, and skew follows the reported asymmetry factor of 1.06. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.31 % impurity against a 99.54 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1GHRP-6 — main peak7.164,837,95399.54
2[D-Trp]-epimer7.0615,0670.310.000
3des-Lys (−128 Da)6.984,8600.10-128.095
4bis-oxidised Trp (+32 Da)6.681,4580.03+31.990
5oxidised Trp (+16 Da)6.889720.02+15.995
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 872.4446 Da, computed from C46H56N12O6. All ppm figures on this site are against monoisotopic values — see why that matters.

0255075100375475575675775875975 [M+1H]1+873.43[M+2H]2+437.22 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, unit-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 872.4259 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
2+437.2296437.2202-0.009456.6
1+873.4519873.4332-0.0187100.0
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

ComponentDetermination%w/w of cake
WaterKarl Fischer3.75
Counter-ion (acetate)ion chromatography4.16
Residual solvent + inorganic residueestimated0.39
Total peptide contentby difference91.70
Total100.00 CLOSES

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.2199.54divergence +0.07 pp vs batch median
Total impurities (% area)-0.040.46
Largest single impurity (% area)-0.020.31
Water (%)2.13.75
Counter-ion (%)not stated4.16
Peptide content (%w/w)not stated91.70
Endotoxin (EU/mg)not statednot determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Buyer-sourced
Evidentiary weight
Strongest available evidence in this index.
Chain of custody
Retail purchase → submitter (ambient, 28 d) → laboratory (hand-carried, 10 d) → assay.
Assay date
24 Mar 2025
Submitted to the index
25 Mar 2025
Laboratory
Medutest, Ljubljana, Slovenia
Method basis
25 min gradient · unit-resolution MS
Verification status
IDENTITY CONSISTENT
Section 6

Annotations 4

Signed technical comments from index contributors. Not a discussion forum — annotations question or contextualise the result, and the data team replies where a reply is warranted.

A longitudinal set of retail purchases from one supplier across four quarters is the strongest supplier-level evidence available. Several contributors here are building exactly that.
multiple_compare
Restricting every supplier comparison to buyer-sourced records is the sensitivity analysis the scorecards publish. On the current dataset it changes no ordering that was not already inside measurement noise.
triptorelin_dtrp
Enantiomeric and epimeric impurities are the extreme case: identical mass, near-identical retention, and separable only by a method chosen for the purpose.
aaa_hydrolysis
Total peptide content and target-compound content are different numbers: the second is the first multiplied by purity. Certificates conflate them routinely and this record separates them.
Section 7

Related records

Same batch — lot SGN-2411-N8496 n=3

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-020650SGN-2411-N8496PeptideMeter2025-Q198.903.79100.9Buyer-sourced1FAIL
AX-2025-020652SGN-2411-N8496PeptideMeter2025-Q199.144.01107.3Buyer-sourced1MARGINAL
Other recent GHRP-6 records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042012AMBAMB-2603-S5667Janoshik2026-Q399.375.9088.8Laboratory-retained1MARGINAL
AX-2026-042528HJHJ-2603-R5329VendorInvestigate2026-Q398.691.8795.8Buyer-sourced0FAIL
AX-2026-042015AMBAMB-2603-S5667Janoshik2026-Q399.546.4497.1Buyer-sourced0PASS
AX-2026-042526HJHJ-2603-R5329Medutest2026-Q399.373.06Laboratory-retained0PASS
AX-2026-042527HJHJ-2603-R5329VendorInvestigate2026-Q399.212.7793.2Buyer-sourced0PASS
AX-2026-042525HJHJ-2603-R5329Janoshik2026-Q399.523.2492.0Buyer-sourced0PASS
AX-2026-042013AMBAMB-2603-S5667Kestrel2026-Q399.935.75Buyer-sourced0PASS
AX-2026-042017AMBAMB-2603-S5667Medutest2026-Q399.766.4297.4Buyer-sourced0PASS
Other recent SGN records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043233AfamelanotideSGN-2602-Y9306Janoshik2026-Q398.764.0292.2Buyer-sourced1MARGINAL
AX-2026-043234AfamelanotideSGN-2602-Y9306Kestrel2026-Q399.934.16Buyer-sourced0PASS
AX-2026-043240SLU-PP-332SGN-2602-X9377Janoshik2026-Q298.825.4697.0Buyer-sourced0PASS
AX-2026-043222ARA-290SGN-2605-X9069PeptideMeter2026-Q298.327.36Buyer-sourced0PASS
AX-2026-043237SLU-PP-332SGN-2602-X9377Janoshik2026-Q298.476.22100.0Supplier-supplied0PASS
AX-2026-043227ARA-290SGN-2605-X9069PeptideMeter2026-Q298.387.2195.6Buyer-sourced0PASS
AX-2026-043239SLU-PP-332SGN-2602-X9377VendorInvestigate2026-Q298.285.37Buyer-sourced0PASS
AX-2026-043229ARA-290SGN-2605-X9069Janoshik2026-Q298.217.43Buyer-sourced0PASS